LINETRAXX® RCMA423 Type B AC/DC residual current monitor, 30 mA…3 A
The LINETRAXX® RCMA423 monitors earthed TN and TT systems for AC and DC fault currents. Response range 30 mA…3 A, 0…2000 Hz, two adjustable response values with a prewarning stage, an LC display and two alarm relays.
- Response range IΔn
- 30 mA…3 A
- Rated frequency
- 0…2000 Hz
- Supply voltage range US (rated)
- AC 24…60 V / DC 24…78 V (RCMA423-D-1), AC/DC 100…250 V (RCMA423-D-2)
- Supply voltage range US (operating)
- AC 16…72 V / DC 9.6…94 V (RCMA423-D-1), AC/DC 70…300 V (RCMA423-D-2)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Smooth DC fault currents in earthed TN and TT power supplies are the case the LINETRAXX® RCMA423 is built for. Its measured value acquisition is AC/DC sensitive (Type B), and it is nearly independent of load current and nominal voltage.
External measuring current transformers detect the residual current. The response range IΔn is 30 mA…3 A with a rated frequency of 0…2000 Hz. Two separately adjustable response values distinguish the main alarm from the prewarning. The measured value appears on an LC display, two separate alarm relays (2 x 1 changeover contact) are fitted and the device settings are password protected.
The RCMA423-D-1 has an operating supply range of AC 16…72 V / DC 9.6…94 V (rated AC 24…60 V / DC 24…78 V), and the RCMA423-D-2 AC/DC 70…300 V (rated AC/DC 100…250 V). Supply frequency is DC, 42…460 Hz. Rated insulation voltage is 100 V for the D-1 and 250 V for the D-2, rated impulse voltage 2.5 kV and 4 kV. Power consumption is up to 6.5 VA.
It mounts on a DIN rail or with screws and measures 93 x 70.5 x 36 mm. Applicable standards include IEC 62020, IEC/TR 60755, IEC 60664-1, IEC 60664-3, IEC 61010-1 and IEC 60947-5-1. External measuring current transformers CTUB101-CTBC20…210(P) and connecting cables CTX-100…1000 are available as options. Typical applications are variable-speed drives, UPS systems, construction site equipment, printing machines, battery systems, laboratory equipment, woodworking machines, MF welding systems and medical electrical equipment.
Technical specifications
| Response range IΔn | 30 mA…3 A |
|---|---|
| Rated frequency | 0…2000 Hz |
| Supply voltage range US (rated) | AC 24…60 V / DC 24…78 V (RCMA423-D-1), AC/DC 100…250 V (RCMA423-D-2) |
| Supply voltage range US (operating) | AC 16…72 V / DC 9.6…94 V (RCMA423-D-1), AC/DC 70…300 V (RCMA423-D-2) |
| Supply frequency US | DC, 42…460 Hz |
| Rated insulation voltage | 100 V (RCMA423-D-1), 250 V (RCMA423-D-2) |
| Rated impulse voltage | 2.5 kV (RCMA423-D-1), 4 kV (RCMA423-D-2) |
| Switching elements | 2 x 1 changeover contact |
| Power consumption | ≤ 6.5 VA |
| Dimensions | 93 x 70.5 x 36 mm |
Part numbers
Show all part numbers (4)
B74043023, B94043023, B74043025, B94043025
How it compares with similar models
| Parameter | LINETRAXX® RCMA423 Type B AC/DC residual current monitor, 30 mA…3 A | LINETRAXX® RCMA420 Type B AC/DC residual current monitor, 10…500 mA | LINETRAXX® MRCDB423 Type B modular residual current device, 30 mA…3 A | LINETRAXX® RCM420 Type A residual current monitor, 10 mA…10 A |
|---|---|---|---|---|
| Response range IΔn | 30 mA…3 A | 10…500 mA | — | 10 mA…10 A |
| Rated insulation voltage | 100 V (RCMA423-D-1), 250 V (RCMA423-D-2) | 100 V (RCMA420-D-1) / 250 V (RCMA420-D-2) | — | 100 V (RCM420-D-1); 250 V (RCM420-D-2) |
| Rated impulse voltage | 2.5 kV (RCMA423-D-1), 4 kV (RCMA423-D-2) | 2.5 kV (RCMA420-D-1) / 4 kV (RCMA420-D-2) | — | 2,5 kV (RCM420-D-1); 4 kV (RCM420-D-2) |
| Dimensions | 93 x 70.5 x 36 mm | 93 x 90 x 70,5 mm | 93 x 74 x 36 mm | 93 x 90 x 74,5 mm |
Request a price and lead time
LINETRAXX® RCMA423 Type B AC/DC residual current monitor, 30 mA…3 A. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What response range does the RCMA423 have?
IΔn is 30 mA…3 A. Two separately adjustable response values set the main alarm and the prewarning.
Does load current affect the measurement?
The device is nearly independent of load current and nominal voltage.
Which supply versions are there?
The RCMA423-D-1 operates on AC 16…72 V / DC 9.6…94 V, the RCMA423-D-2 on AC/DC 70…300 V.