UFA/UMA710-ISO two-pole changeover and IT system monitoring modules, 63 and 80 A

UMA710-2-…-ISO and UFA710-2-… change a medical IT system over between two supplies and monitor its insulation. The UFA adds an integrated insulation fault locator for 6, 12, 18 or 24 circuits. Ratings are 63 and 80 A, with changeover in ≤ 0.5 s.

Versions
UMA710-2-…-ISO (without insulation fault locator); UFA710-2-…-ISO (with integrated locator)
Nominal current (AC3), changeover module
63 A; 80 A
Max. admissible current acc. to DIN VDE 0100-710
63 A; 80 A
Upstream fuse, max
80 A gG; 100 A gG

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

These are factory-made two-pole modules for group 2 medical locations such as operating theatres and intensive care units. They change the supply over between a preferred and a redundant source and monitor the IT system at the same time. The UMA710-2-…-ISO version has no insulation fault locator, whereas the UFA710-2-… version has one built in.

An ATICS® automatic transfer switching device performs the changeover. It moves the load to the redundant supply within t ≤ 0.5 s, and the variable changeover period can be set between ≤ 0.5 and 15 s. The module monitors voltage, load current and insulation resistance, and reports its status over the BMS bus. Functional safety follows IEC 61508 (SIL 2). Values for the changeover module follow DIN VDE 0100-710: a nominal current of 63 A or 80 A, with upstream fuses of up to 80 A gG and 100 A gG.

The UFA710-2-… version carries an integrated insulation fault locator for 6, 12, 18 or 24 outgoing circuits, and its order codes end in 06, 12, 18 or 24 followed by B16. Each 63 A or 80 A version is built with a bypass switch (BP) or without one. The UMA710-2-…-ISO version suits systems that need no insulation fault location. For systems already in service, the UMA710-2-63-ISO-RF retrofit version exists.

CP9xx and CP305 alarm indicators connect to the module, and the EDS151 serves as the insulation fault locator. Consumption across the versions runs from 16 W to 31 W according to the technical data. Mounting is on a DIN rail. The modules meet IEC 60364-7-710 and DIN VDE 0100-710, and a TÜV certification test is optional.

Technical specifications

VersionsUMA710-2-…-ISO (without insulation fault locator); UFA710-2-…-ISO (with integrated locator)
Nominal current (AC3), changeover module63 A; 80 A
Max. admissible current acc. to DIN VDE 0100-71063 A; 80 A
Upstream fuse, max80 A gG; 100 A gG
Consumption, approx.16 W; 17 W; 18 W; 19 W; 22 W; 28 W; 29 W; 30 W; 31 W
Changeover timest ≤ 0.5 s
Variable changeover periodt ≤ 0.5…15 s
Outgoing circuits, UFA6; 12; 18; 24
Bypass switchBP version
MountingDIN rail
BusBMS
Functional safetySIL 2 (IEC 61508)
StandardsDIN VDE 0100-710; IEC 60364-7-710; IEC 61508

Part numbers

Show all part numbers (6)

UFA710-2-63-ISO-06-B16 … UFA710-2-80-ISO-BP-24-B16, UMA710-2-63-ISO, UMA710-2-80-ISO, UMA710-2-63-ISO-BP, UMA710-2-80-ISO-BP, UMA710-2-63-ISO-RF

How it compares with similar models

ParameterUFA/UMA710-ISO two-pole changeover and IT system monitoring modules, 63 and 80 AUMA710-DIO changeover and monitoring module for 80, 125 and 160 ALINETRAXX® RCM410R-24/-2 single-channel residual current monitoring relay, 10 mA…30 AATICS®-2/4-…-DIO automatic transfer switching devices for safety power supplies, 63 to 160 A
MountingDIN railDIN railDIN railDIN rail or mounting plate (M5 screws)
Functional safetySIL 2 (IEC 61508)SIL 2 (IEC 61508)—SIL 2
StandardsDIN VDE 0100-710; IEC 60364-7-710; IEC 61508—DIN EN IEC 62020-1, UL508, UL1053, IEC 60664-1, IEC 61010-1, IEC 60947-5-1DIN VDE 0100-710; IEC 60364-7-710; DIN VDE 0100-718; DIN VDE 61508

Request a price and lead time

UFA/UMA710-ISO two-pole changeover and IT system monitoring modules, 63 and 80 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How does the UFA differ from the UMA?

The UFA710-2-… has an integrated insulation fault locator for 6, 12, 18 or 24 circuits, while the UMA710-2-…-ISO has none.

Which current ratings and changeover time apply?

The changeover module is rated 63 A or 80 A. Changeover takes t ≤ 0.5 s, with a variable period of ≤ 0.5…15 s.

Is a version with a bypass switch available?

Yes. Bypass (BP) versions exist for 63 A and 80 A, and the UMA710-2-63-ISO-RF is offered as a retrofit version.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides