ATICS®-2-…-ISO automatic transfer switching device with IT system monitoring, 63 and 80 A
The ATICS®-2-63A-ISO and ATICS®-2-80A-ISO change a load over between two independent supplies and monitor the insulation of an unearthed IT system. Versions for AC 240 V and AC 415 V, 63 and 80 A, with functional safety to SIL 2.
- Rated operational current Ie
- AC 63 A; AC 80 A
- Rated operational voltage Ue
- AC 240 V; AC 415 V (-400 version)
- Supply voltage Us
- 230 V (50/60 Hz)
- Power consumption
- ≤ 16 W (63 A); ≤ 28 W (80 A)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Unearthed safety power supplies in medical facilities are the target of the ATICS®-2-…-ISO, a compact transfer switching device with integrated IT system monitoring. It changes the load over between two independent supplies and measures insulation resistance, which suits group 2 medical locations, intensive care units and operating theatres.
The switch disconnector and the control electronics share one flat enclosure. Voltage monitoring drives the automatic change from the preferred to the redundant line, while insulation monitoring of the IT system runs continuously. Optional bypass switches permit testing without a supply interruption. A graphic display shows the status and a history memory keeps the record. Functional safety is SIL 2 under DIN EN 61508, and the device carries TÜV SÜD certification and the CE and UKCA marks.
The versions differ in current and voltage. The ATICS-2-63A-ISO and ATICS-2-80A-ISO are for AC 240 V, and the ATICS-2-63A-ISO-400 and ATICS-2-80A-ISO-400 for AC 415 V. The -ES versions add a connection for the ATICS-ES energy storage device. The supply voltage Us is 230 V (50/60 Hz), consumption is ≤ 16 W at 63 A and ≤ 28 W at 80 A, and the current during changeover is 17 A / < 30 ms. Mechanical endurance is ≥ 8000 operating cycles, the frequency range is 48…62 Hz and the crest factor is ≤ 1.2.
The signalling contact is rated 5 A / AC 250 V and 5 A / DC 30 V. The device has one digital input, one potential-free changeover contact and an RS-485 interface with the BMS protocol. Its degree of protection is IP40, the operating temperature is -25…+55 °C, and it measures 234 × 270 × 73 and weighs ca. 3400 g. It mounts on a DIN rail to IEC 60715. Current transformers STW2, STW3 and SWL-100A and the EDS151 insulation fault locator are offered as accessories.
Technical specifications
| Rated operational current Ie | AC 63 A; AC 80 A |
|---|---|
| Rated operational voltage Ue | AC 240 V; AC 415 V (-400 version) |
| Supply voltage Us | 230 V (50/60 Hz) |
| Power consumption | ≤ 16 W (63 A); ≤ 28 W (80 A) |
| Current during changeover | 17 A / < 30 ms |
| Frequency range fn | 48…62 Hz |
| Crest factor | ≤ 1.2 |
| Operating cycles (mechanical) | ≥ 8000 |
| Rated insulation voltage | 250 V |
| Signalling contact | 5 A / AC 250 V; 5 A / DC 30 V |
| Interface | RS-485/BMS |
| Degree of protection | IP40 |
| Operating temperature | -25…+55 °C |
| Mounting | DIN rail (IEC 60715) |
| Dimensions (W × H × D) | 234 × 270 × 73 |
| Weight | ca. 3400 g |
Part numbers
Show all part numbers (6)
ATICS-2-63A-ISO, ATICS-2-63A-ISO-ES, ATICS-2-63A-ISO-400, ATICS-2-80A-ISO, ATICS-2-80A-ISO-ES, ATICS-2-80A-ISO-400
How it compares with similar models
| Parameter | ATICS®-2-…-ISO automatic transfer switching device with IT system monitoring, 63 and 80 A | LINETRAXX® CEP410R-2 residual current monitor for the central earthing point | VIT-AFSBY isolated power panels with ATICS® changeover, fault locator and bypass, 5000 to 8000 VA | ISOMETER® IR425-D4 insulation monitor for AC/DC IT systems 0…300 V, response values 1…200 kΩ |
|---|---|---|---|---|
| Rated insulation voltage | 250 V | 250 V | AC 400 V | 250 V |
| Degree of protection | IP40 | IP20 | IP21 | — |
| Operating temperature | -25…+55 °C | -25…+55 °C | -10…+55 °C | -25…+55 °C |
| Weight | ca. 3400 g | ≤ 100 g | — | approx. 150 g |
Request a price and lead time
ATICS®-2-…-ISO automatic transfer switching device with IT system monitoring, 63 and 80 A. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which currents and voltages are available?
AC 63 A and AC 80 A, for AC 240 V, or for AC 415 V in the -400 versions.
What is the -ES version for?
The -ES version adds a connection for the ATICS-ES energy storage device.
What are the protection degree, size and weight?
The degree of protection is IP40, the size 234 × 270 × 73 and the weight ca. 3400 g, mounted on a DIN rail.