VIT-A isolated power panels with ATICS® changeover for operating theatres, 5000 to 8000 VA

The VIT-A series feeds socket-outlet circuits in group 2 medical locations such as operating theatres. Each cabinet holds an isolating transformer of 5000, 6300 or 8000 VA, an ATICS® changeover and monitoring module and insulation monitoring to DIN VDE 100-710 and IEC 60364-7-710.

Transformer rating
5000 VA; 6300 VA; 8000 VA
Rated power
3150…8000 VA
Rated voltage
AC 230 V
Frequency
50…60 Hz

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

A VIT-A cabinet serves group 2 medical locations, operating theatres in particular. Socket-outlet circuits for medical electrical equipment above AC 25 V or DC 60 V need the protective measure of insulation monitoring with indication in an IT system, and a changeover module must move the load from the safety power source to a second supply after a failure. Because such rooms have many socket circuits, an insulation fault locator is built into the VIT-A.

Inside the IT system cabinet sit an isolating transformer and a UMA710-2-xx-ISO-… changeover and monitoring module with all the monitoring DIN VDE 100-710 calls for. The ATICS® device checks incoming and output voltage, operating times, changeover times, insulation resistance, load current and transformer temperature. Functional safety follows IEC 61508 (SIL 2) and the changeover time is variable, ≤ 0.5…15 s. Voltage monitoring has an adjustable control function on the preferred line, the second line and the module output.

Up to 12 or 24 outgoing circuits are fitted with 2-pole B16 A circuit breakers. The energy-efficient 6300 and 8000 VA transformers have an inrush current < 5 x In, and the waste heat is removed by natural convection, without fans, even at full transformer load. A bypass switch for uninterrupted testing and replacement is optional and recommended. Information is exchanged over a bus, and remote alarm indicator and operator panels MK2430, CP305 and CP9xx connect to the module.

The 112S measures 374 x 2025 x 425 mm and the 114S 374 x 2325 x 425 mm. The degree of protection is IP21, the protection class SK I (earthed), and the weight runs from ca. 145 kg to ca. 170 kg depending on the transformer. The sheet steel housing follows DIN VDE 0100-710 and is delivered as a ready-to-connect free-standing cabinet with a door and a plinth. Design verification covers IEC 61439-1, -2 and IEC 60364-7-710, and the changeover module can be tested voluntarily by TÜV.

Technical specifications

Transformer rating5000 VA; 6300 VA; 8000 VA
Rated power3150…8000 VA
Rated voltageAC 230 V
Frequency50…60 Hz
Outgoing circuits12 (VIT-A-112S); 24 (VIT-A-114S); B16 A breakers
Insulation voltageAC 400 V
Changeover time≤ 0.5…15 s
Measuring range (insulation)10 k…1 MΩ
Measuring range (current)0…200 A
InterfaceRS-485/BMS
Operating temperature-10…+55 °C
Degree of protectionIP21
Protection classSK I (earthed)
Dimensions 112S / 114S374 x 2025 x 425 mm / 374 x 2325 x 425 mm
Weight 112S: 5000 / 6300 / 8000 VAca. 145 kg / ca. 150 kg / ca. 160 kg
Weight 114S: 5000 / 6300 / 8000 VAca. 155 kg / ca. 160 kg / ca. 170 kg

Part numbers

Show all part numbers (6)

VIT-A-112S-5000, VIT-A-112S-6300, VIT-A-112S-8000, VIT-A-114S-5000, VIT-A-114S-6300, VIT-A-114S-8000

How it compares with similar models

ParameterVIT-A isolated power panels with ATICS® changeover for operating theatres, 5000 to 8000 VAVIT-AFSBY isolated power panels with ATICS® changeover, fault locator and bypass, 5000 to 8000 VAAN450 power supply unit, AC 20 V, up to 9 VA, for MK2430ATICS®-2-…-ISO automatic transfer switching device with IT system monitoring, 63 and 80 A
Operating temperature-10…+55 °C-10…+55 °C-10…+55 °C-25…+55 °C
Degree of protectionIP21IP21IP30/IP20IP40

Request a price and lead time

VIT-A isolated power panels with ATICS® changeover for operating theatres, 5000 to 8000 VA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which transformer ratings and circuit counts are offered?

Transformers of 5000, 6300 or 8000 VA. The VIT-A-112S has 12 circuits and the VIT-A-114S has 24, with 2-pole B16 A breakers.

Does the panel include a bypass switch?

A bypass switch for testing and replacement without a supply interruption is optional and recommended.

What are the weight and dimensions of the cabinet?

The 112S measures 374 x 2025 x 425 mm and the 114S 374 x 2325 x 425 mm, with a weight from ca. 145 kg to ca. 170 kg depending on the version.