WN series measuring current transformers for AC and DC residual current

The WN series are measuring current transformers that detect AC and DC residual currents in DC, AC and 3(N)AC systems. An integrated metal shield screens out external magnetic fields. Two versions are listed, WN-12-01 and WN-18-10.

Type
Вимірювальний трансформатор струму
Detected currents
AC and DC residual currents
Systems
DC, AC, 3(N)AC
Interference protection
Integrated metal shield

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

A WN transformer picks up AC and DC residual current in DC, AC and 3(N)AC systems. The series sits mainly in electric vehicle charging equipment, where it is paired with an electronic evaluation unit that handles the fault current measurement.

A metal shield is built into the housing. It keeps interference from external magnetic fields and from high load currents out of the measurement, so readings hold up close to power conductors.

The transformer is not used alone. Electronic units such as the RCMB104 and RDC104 complete it: they take the transformer signal and act on a residual current above the set level.

The series is suitable for fault current measurement in charging mode 2, with an IC-CPD, and in charging mode 3, in AC wallboxes and AC stations. Residual current monitoring in such equipment is covered by IEC 62752 and IEC 62955.

Two versions are listed. WN-12-01 carries article number B98080060 and WN-18-10 carries B98080062; further parameters are selected by the version code.

Technical specifications

TypeВимірювальний трансформатор струму
Detected currentsAC and DC residual currents
SystemsDC, AC, 3(N)AC
Interference protectionIntegrated metal shield
Charging modes2 (IC-CPD), 3 (AC wallbox, AC station)
StandardsIEC 62752, IEC 62955
VersionsWN-12-01, WN-18-10

Part numbers

Show all part numbers (2)

WN-12-01: B98080060, WN-18-10: B98080062

Request a price and lead time

WN series measuring current transformers for AC and DC residual current. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which residual currents does the WN series measure?

Both AC and DC residual currents, in DC, AC and 3(N)AC systems.

Which evaluation units go with the WN transformers?

Electronic units such as the RCMB104 and RDC104, which complete the transformer for fault current measurement.

Is the transformer protected against external interference?

Yes, an integrated metal shield reduces the effect of external magnetic fields and high load currents.