WS… and WS…-8000 split-core measuring current transformers for residual current monitoring

WS… and WS…-8000 split-core transformers open at an interlock knob to enclose the conductors, so they fit into existing installations. They serve RCM and RCMS residual current monitors and EDS insulation fault locators, with a rated insulation voltage of 800 V.

Type
Split-core measuring current transformer
WS… versions
WS20x30, WS50x80, WS80x120
WS…-8000 versions
WS20x30-8000, WS50x80-8000
Rated insulation voltage
800 V

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Split-core transformers of the WS… and WS…-8000 series open with an interlock knob and close around the conductors to be monitored, which makes retrofitting in an existing installation straightforward. They are highly sensitive: together with RCM and RCMS residual current monitors they turn AC currents into a signal that can be evaluated.

WS… types go with RCMS460/490 and RCMS470 monitoring systems, RCM420, RCM460 and RCM470 monitors, and EDS460/490 and EDS470 insulation fault location systems. In IT systems they measure the locating current produced by a PGH injector or an ISOMETER® IRDH. WS…-8000 types are meant for the EDS473(E)-12, EDS474(E)-12, EDS461 and EDS491 evaluators. A two-wire cable makes the connection.

There are five sizes by internal opening: WS20x30, WS50x80 and WS80x120, plus WS20x30-8000 and WS50x80-8000. Rated insulation voltage is 800 V, rated impulse voltage 8 kV at pollution degree 3. The frequency range is 42 Hz…3 kHz and the operating temperature -25…+70 °C.

For WS… the rated primary residual current is 10 A and the secondary 0.0167 A, with a burden up to 180 Ω. Rated continuous thermal current Icth is 40 A, short-time Ith 2.4 kA/1 s and dynamic Idyn 6.0 kA/40 ms. For WS…-8000 the primary current is 1 A, the secondary 0.125 mA, Icth 6 A, Ith 0.36 kA/1 s and Idyn 0.9 kA/40 ms. The transformers comply with IEC 61869-1. Qualified electricians should carry out installation and commissioning.

Technical specifications

TypeSplit-core measuring current transformer
WS… versionsWS20x30, WS50x80, WS80x120
WS…-8000 versionsWS20x30-8000, WS50x80-8000
Rated insulation voltage800 V
Rated impulse voltage / pollution degree8 kV/3
Frequency range42 Hz…3 kHz
Rated primary residual current (WS…)10 A
Rated secondary residual current (WS…)0.0167 A
Rated burden (WS…)max. 180 Ω
Rated output (WS…)0.05 VA
Icth / Ith / Idyn (WS…)40 A / 2.4 kA/1 s / 6.0 kA/40 ms
Rated primary residual current (WS…-8000)1 A
Rated secondary residual current (WS…-8000)0.125 mA
Icth / Ith / Idyn (WS…-8000)6 A / 0.36 kA/1 s / 0.9 kA/40 ms
Operating temperature-25…+70 °C
StandardIEC 61869-1

Part numbers

Show all part numbers (5)

B98080601, B98080602, B98080603, B98080604, B98080606

How it compares with similar models

ParameterWS… and WS…-8000 split-core measuring current transformers for residual current monitoringLINETRAXX® CTAS50, CTAS80, CTAS120 and CTAS…/01 divisible measuring current transformersWS50x80S…WS80x160S split-core current transformers for residual currents of 10 mA…100 ALINETRAXX® CTAC20, CTAC35, CTAC60, CTAC120 and CTAC210 measuring current transformers
TypeSplit-core measuring current transformerDivisible measuring current transformerSplit-core measuring current transformerMeasuring current transformer
Rated impulse voltage / pollution degree8 kV/38 kV / 3—8 kV/3
Frequency range42 Hz…3 kHz42 Hz…3 kHz—15 Hz…100 kHz
Operating temperature-25…+70 °C-25…+70 °C—-25…+70 °C (standard); -40…+70 °C (B781100xxMIL)

Request a price and lead time

WS… and WS…-8000 split-core measuring current transformers for residual current monitoring. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What separates WS… from WS…-8000?

WS… types work with RCMS460/490, RCM420/RCM460 and EDS460/490, while WS…-8000 types work with EDS473(E)-12, EDS474(E)-12, EDS461 and EDS491. Primary residual current is 10 A for WS… and 1 A for WS…-8000.

Which internal openings are available?

20 x 30 mm, 50 x 80 mm and 80 x 120 mm for WS…, and 20 x 30 mm and 50 x 80 mm for WS…-8000.

Can the transformer be fitted without disconnecting conductors?

Yes. The interlock knob opens the core, which is then closed around the conductors in the live installation.