International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

SO-54SR-101/111-REK, SO-54SR-122 — controllers for recloser and circuit breakers on MV overhead lines

Controllers of the SO-54SR series control reclosers and circuit breakers of medium voltage overhead lines in networks with telecontrol. They combine protection against phase-to-phase short circuits and earth faults, auto-reclosing, measurement, remote control and fault recording. They are used on 15–30 kV overhead lines in networks built on the Smart Grid concept.

SO-54SR-101-REK / 111-REK
complete handling of the RC 27 overhead line circuit breaker (THO-RC 27, GVR); 111-REK with protection functions
SO-54SR-101-AUT
controller with simplified automation
SO-54SR-122
controller with protection automation functions for control cabinets of overhead line and indoor breakers
Functions
protection against short circuits and earth faults, auto-reclosing, telecontrol, recording

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The series consists of several versions. SO-54SR-101-REK provides complete handling of the RC 27 outdoor circuit breaker (THO-RC 27, GVR), and SO-54SR-111-REK and its -1.4 version add protection functions to this. SO-54SR-101-AUT has simplified automation, while SO-54SR-122 with protection automation serves control cabinets of overhead line breakers and indoor breakers. Simpler telecontrol controllers for overhead line points, SO-54SR-901/902 and USP-120/140/142/143, complete the series.

A controller with protection automation functions becomes the basis of control cabinets for overhead and indoor breakers of various types in MV networks. It limits the consequences of earth faults and multi-phase short circuits, performs auto-reclosing, and controls the breaker remotely from SCADA and locally. The protection algorithms have four setting banks, a disturbance recorder is built into the device, and inrush current restraint works on the second harmonic. Discrete signals from the facility are read with a resolution of 1 ms.

As standard, SO-54SR-1xx-REK has an integrated graphic terminal, an LED signalling panel with replaceable label inserts and control buttons. The design is produced in two variants: the first works with an external measuring interface IPR-xxx, the second needs no intermediate circuits. The controller is configured remotely or locally with a dedicated program.

In the recloser control cabinet the controller is installed together with a mobile communication modem, a battery with a charger and local control elements. Communication with SCADA runs as standard over TETRA and/or GPRS/UMTS/LTE in dedicated APNs through an external communication module, using DNP 3.0 over TCP/IP or UDP and IEC 60870-5-104. CDMA2000, DMR, and serial or network dedicated channels with IEC 60870-5-101, IEC 60870-5-103 and Modbus protocols are also possible.

Reclosers with such controllers perform automatic isolation of the faulted section and restoration of supply in the FDIR functions of the SYNDIS system. They are typically installed on reclosers and automatic sectionalising points of 15–30 kV overhead lines, on trunk lines and branches of distribution networks. Brochures are published for SO-54SR and SO-54SR-111-REK-1.4.

Technical specifications

SO-54SR-101-REK / 111-REKcomplete handling of the RC 27 overhead line circuit breaker (THO-RC 27, GVR); 111-REK with protection functions
SO-54SR-101-AUTcontroller with simplified automation
SO-54SR-122controller with protection automation functions for control cabinets of overhead line and indoor breakers
Functionsprotection against short circuits and earth faults, auto-reclosing, telecontrol, recording
CommunicationGPRS/UMTS/LTE, TETRA, etc.

Request a price and lead time

SO-54SR-101/111-REK, SO-54SR-122 — controllers for recloser and circuit breakers on MV overhead lines. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8537 10 98 00
HS, 6 digits8537 10
CN (EU)8537 10 98
HTSUS (USA)8537 10 91 70
China customs tariff8537 10 90 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Which reclosers does SO-54SR-101-REK work with?

The controller serves the RC 27 outdoor circuit breaker in the THO-RC 27 and GVR versions. SO-54SR-111-REK is intended for the same breaker with protection functions.

How many setting banks does the controller have?

The protection automation algorithms of SO-54SR-1xx-REK have four setting banks. A disturbance recorder is built into the device, and discrete signals are read with a resolution of 1 ms.

Which communication channels with SCADA do SO-54SR controllers support?

As standard, communication runs over TETRA and GPRS/UMTS/LTE in dedicated APNs using DNP 3.0 and IEC 60870-5-104. CDMA2000, DMR and dedicated serial or network channels are also possible.

Similar equipment from other manufacturers