EOR-3DS / EOR-1DS — short-circuit and earth fault indicators for MV networks

EOR-3DS and EOR-1DS combine short-circuit and earth fault indication in one device for MV networks with isolated and compensated neutral. They are installed in distribution substations and switching stations to shorten the search for the faulted section and to send signals to the control system.

Networks
MV with isolated and compensated neutral
Functions
directional and non-directional short-circuit and earth fault indication, fault recording
Sensors
SR55 Rogowski phase current sensors, low-power current and voltage sensors
EOR-3DS
freely programmable, remote control of load-break switches, substation digitalisation unit

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The devices provide directional and non-directional indication of short circuits and earth faults and also record faults. Phase current is taken by SR55 Rogowski sensors; low-power current and voltage sensors can be connected. EOR-3DS is freely programmable, controls load-break switches via the remote control channel and can work as a substation digitalisation unit. EOR-1DS is simpler and more economical, with Modbus RTU and 32 GB memory. The functions comply with IEC 60255, IEC 61869 and IEC 60870.

Technical specifications

NetworksMV with isolated and compensated neutral
Functionsdirectional and non-directional short-circuit and earth fault indication, fault recording
SensorsSR55 Rogowski phase current sensors, low-power current and voltage sensors
EOR-3DSfreely programmable, remote control of load-break switches, substation digitalisation unit
EOR-1DSeconomical, Modbus RTU, 32 GB memory
StandardsIEC 60255, IEC 61869, IEC 60870

Request a price and lead time

EOR-3DS / EOR-1DS — short-circuit and earth fault indicators for MV networks. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8536 49 00 90
HS, 6 digits8536 49
CN (EU)8536 49 00
HTSUS (USA)8536 49 00 80
China customs tariff8536 49 00 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

In which networks do EOR indicators work?

In MV networks with isolated and with compensated neutral, detecting both short circuits and earth faults.

How does EOR-3DS differ from EOR-1DS?

EOR-3DS is freely programmable, controls load-break switches and serves as a substation digitalisation unit. EOR-1DS is economical, with Modbus RTU and 32 GB memory.

Which current sensors can be connected to the indicators?

SR55 Rogowski phase current sensors, as well as low-power current and voltage sensors.