SEB30 and SEB60 supplementary equipotential bonding bus bar, 30 and 60 terminals
SEB30 and SEB60 connect all conductive and extraneous conductive parts of the patient environment in medical locations of group 1 and 2 under IEC/HD 60364-7-710. The bus bar has 30 or 60 screwless terminals for conductors up to 25 mm².
- Number of terminals
- 30 (SEB30); 60 (SEB60)
- Mounting
- flush (UPB) / surface (AP)
- Conductor cross-section
- up to 25 mm², solid or fine stranded
- Conductor connection
- direct push-in, no screws
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The SEB bus bar provides the supplementary equipotential bonding required in each medically used room of group 1 and 2. IEC/HD 60364-7-710 covers hospitals, clinics, medical and dental practices and any other place where electro-medical devices with parts applied to the patient are used. The aim is to keep medical staff and patients safe when they touch electro-medical equipment.
The bus bar links galvanically every conductive part and extraneous conductive part present in the patient environment or able to enter it. If one of these parts develops a fault, all of them stay at the same potential, so a patient touching two or more parts is not exposed to hazardous currents.
Solid or fine stranded conductors up to 25 mm² are pushed straight into the terminal. No crimping tools or torque wrenches are needed, and nothing has to be retightened at inspection. For testing, each terminal can be disconnected from the bus bar without removing its conductor, and there is reserved space for clamp-on current meters. The bus bar is tin-plated and does not corrode. A self-adhesive label with a wiring list identifies every conductor.
Items connected to the SEB include equipotential receptacles, operating lights, operating tables, electrical booms and pendants, metal screens that reduce EMC fields, conductive floor grids and screens, water piping, metal drains and medical gas piping. Metal furniture and metal parts of furnishings need no connection. The screen of the IT system transformer and the protective earth conductors of the branch circuits go by the shortest route to the PE inside the isolated power system (IPS).
The SEB30 carries 30 terminals and the SEB60 carries 60. The UPB types are flush mounted and the AP types are surface mounted, either in a wall box with bezel frame or in a surface enclosure. Keep the bus bar easy to reach for regular inspection.
Technical specifications
| Number of terminals | 30 (SEB30); 60 (SEB60) |
|---|---|
| Mounting | flush (UPB) / surface (AP) |
| Conductor cross-section | up to 25 mm², solid or fine stranded |
| Conductor connection | direct push-in, no screws |
| Bus bar | tin-plated |
| Weight SEB30 / SEB30-AP | 7.7 kg / 10 kg |
| Weight SEB60 / SEB60-AP | 13.7 kg / 15 kg |
| Standard | IEC/HD 60364-7-710 |
Part numbers
Show all part numbers (4)
BF22302201 (SEB30), BF22302203 (SEB30-AP), BF22302202 (SEB60), BF22302204 (SEB60-AP)
How it compares with similar models
| Parameter | SEB30 and SEB60 supplementary equipotential bonding bus bar, 30 and 60 terminals | ISOMETER® iso1685DP, isoHV1685D and isoLR1685DP insulation monitors for IT systems up to AC 2000 V / DC 3000 V | UFA/UMA710-ISO two-pole changeover and IT system monitoring modules, 63 and 80 A | RCMB123 AC/DC differential current sensor for IC-CPD to IEC 62752 |
|---|---|---|---|---|
| Mounting | flush (UPB) / surface (AP) | DIN rail | DIN rail | PCB mounting |
| Standard | IEC/HD 60364-7-710 | IEC 61557-8; IEC 61557-8 Appendix C | — | IEC 62752:2016 |
Request a price and lead time
SEB30 and SEB60 supplementary equipotential bonding bus bar, 30 and 60 terminals. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How many conductors can be connected, and what size?
The SEB30 has 30 terminals and the SEB60 has 60. Each terminal takes a solid or fine stranded conductor up to 25 mm² by direct push-in.
Must a conductor be removed to measure a circuit?
No. Each terminal can be disconnected from the bus bar with the conductor left in place, and there is reserved space for clamp-on current meters.
What is connected to the SEB and what is not?
All conductive and extraneous conductive parts in the patient environment, such as operating tables, lights, piping and floor screens. Metal furniture need not be connected.
Similar equipment from other manufacturers