RCMB121-2 AC/DC differential current sensor for IC-CPD to UL2231

The RCMB121-2 is a fluxgate differential current sensor with a toroidal core for PCB mounting. It responds to AC and DC current and has open-collector outputs. It is intended for personnel protection systems for electric vehicles to UL2231.

Type
Differential current sensor, fluxgate with toroidal core
Mounting
PCB mounting
Primary nominal current (1 phase / 3 phase)
80 / 40 A
Rated residual operating current 1
5 mA rms

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The RCMB121-2 detects fault current in IC-CPD units and in personnel protection systems for electric vehicles under UL2231, in stationary as well as mobile equipment. It is sensitive to AC and DC current and assesses fault currents to UL2231-2 Ed.2.

The sensing element is a fluxgate with a toroidal core. The sensor is soldered to a printed circuit board and uses AEC-Q qualified components. Its outputs are open-collector.

At a fault current of 5 mA rms, pin 3 goes from a low level (GND) to high impedance. At 20 mA rms, pins 3 and 4 both change to high impedance. Errors, including internal ones, are signalled on pin 1 (ERROR-OUT), which also goes to high impedance.

Primary rated current is 80 A for a single phase and 40 A for three phases. The measuring range is -300 to +300 mA, resolution is below 0.2 mA and the frequency range runs from DC to 2 kHz. Response time follows UL2231-2 Ed.2. Operating and storage temperature is -40 to 85 °C, mass is 21 g and the supply is 5 V (4.8 to 5.2 V).

With insulated primary conductors, insulation coordination is as follows: reinforced insulation, insulation material group 1, pollution degree 2, sea level up to 4000 m and overvoltage category II. Insulated wires are preferred.

Technical specifications

TypeDifferential current sensor, fluxgate with toroidal core
MountingPCB mounting
Primary nominal current (1 phase / 3 phase)80 / 40 A
Rated residual operating current 15 mA rms
Rated residual operating current 220 mA rms
Measuring range-300…+300 mA
Resolution< 0.2 mA
Frequency rangeDC…2 kHz
Operating and storage temperature-40…85 °C
Mass21 g
Supply voltage5 V (4.8…5.2 V)
OutputsOpen collector
StandardUL2231-2 Ed.2

Part numbers

Show all part numbers (2)

B94042491, T60404-N4641-X901

How it compares with similar models

ParameterRCMB121-2 AC/DC differential current sensor for IC-CPD to UL2231RCMB123 AC/DC differential current sensor for IC-CPD to IEC 62752RDC121-5S fluxgate residual current sensor for AC charging stationsRDC104-4 DC residual current monitoring module for AC charging stations to IEC 62955
TypeDifferential current sensor, fluxgate with toroidal coreDifferential current sensor, fluxgate with toroidal coreDifferential current sensor, fluxgate with toroidal coreDC sensitive residual current monitoring module
Measuring range-300…+300 mA-300…+300 mA—±300 mA
Supply voltage5 V (4.8…5.2 V)5 V (4.8…5.2 V)5 V DCDC 5 V
OutputsOpen collectorOpen collectorOpen collectorSwitch1, Switch2, Error, PWM
StandardUL2231-2 Ed.2IEC 62752:2016—IEC 62955

Request a price and lead time

RCMB121-2 AC/DC differential current sensor for IC-CPD to UL2231. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which standard does the RCMB121-2 follow?

It detects fault currents to UL2231-2 Ed.2 and is intended for IC-CPD units and personnel protection systems for electric vehicles.

At what currents do the outputs change state?

Pin 3 changes at 5 mA rms, and pins 3 and 4 change at 20 mA rms.

What is the primary rated current?

80 A for a single phase and 40 A for three phases.