RDC104-4 DC residual current monitoring module for AC charging stations to IEC 62955
The RDC104-4 evaluates the signal of a measuring current transformer and watches for DC residual current in AC charging stations to IEC 62955. The range is ±300 mA with a resolution below 0.2 mA. It mounts on the customer's own PCB.
- Type
- DC sensitive residual current monitoring module
- Measuring range
- ±300 mA
- Resolution
- < 0.2 mA
- Rated current
- 32 A (single-phase) / 3 x 32 A (three-phase)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The RDC104-4 is used with a measuring current transformer, for example the CTBC17, and a type A RCD provided in the installation. It is intended for AC charging stations for electric vehicles (mode 3) under IEC 62955, where AC or DC fault currents can occur.
The residual current evaluation consists of the external transformer, which measures, and the module, which evaluates. A patented method gives the RMS value of the DC component of the residual current and of the AC component below the cut-off frequency. The range is ±300 mA, resolution is below 0.2 mA, and rated current is up to 32 A single-phase or 3 x 32 A RMS three-phase.
Switch1 and Switch2 signal that a limit value is exceeded, and with a type A RCD the disconnection conditions of IEC 62955 are met. In all there are four outputs: Switch1, Switch2, Error and PWM. The fault output is linked to integrated self-monitoring and test functions. The charge controller must check that the module works before each charging process, and regular testing prevents drift of the measurement through an internal offset measurement.
The transformer is magnetically shielded, so external interference does not affect the reading. In IEC 62955 applications the module, with a type A RCD and a suitable switching device such as a power relay, can replace a type B RCD.
The module is soldered or plugged into the customer's PCB, with conductor tracks to the pins no longer than 100 mm. It is for makers of charging systems and not for end users. Supply is DC 5 V, operating temperature is -30 to 80 °C and protection is IP00.
Technical specifications
| Type | DC sensitive residual current monitoring module |
|---|---|
| Measuring range | ±300 mA |
| Resolution | < 0.2 mA |
| Rated current | 32 A (single-phase) / 3 x 32 A (three-phase) |
| Rated voltage | 250 V |
| Supply voltage | DC 5 V |
| Operating temperature | -30…80 °C |
| Degree of protection | IP00 |
| Outputs | Switch1, Switch2, Error, PWM |
| Standard | IEC 62955 |
Part numbers
Show all part numbers (7)
B94042483, трансформатор / трансформатор / transformer: B98080070, B98080071, кабелі / кабели / cables: B98080540, B98080541, B98080542, B98080543
How it compares with similar models
| Parameter | RDC104-4 DC residual current monitoring module for AC charging stations to IEC 62955 | RCMB104 AC/DC residual current monitoring module for EV charging systems | RCMB123 AC/DC differential current sensor for IC-CPD to IEC 62752 | RCMB121-2 AC/DC differential current sensor for IC-CPD to UL2231 |
|---|---|---|---|---|
| Type | DC sensitive residual current monitoring module | AC/DC sensitive residual current monitoring module | Differential current sensor, fluxgate with toroidal core | Differential current sensor, fluxgate with toroidal core |
| Measuring range | ±300 mA | ±300 mA | -300…+300 mA | -300…+300 mA |
| Supply voltage | DC 5 V | — | 5 V (4.8…5.2 V) | 5 V (4.8…5.2 V) |
| Outputs | Switch1, Switch2, Error, PWM | Switch1, Switch2, Error, PWM | Open collector | Open collector |
| Standard | IEC 62955 | — | IEC 62752:2016 | UL2231-2 Ed.2 |
Request a price and lead time
RDC104-4 DC residual current monitoring module for AC charging stations to IEC 62955. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which standard does the RDC104-4 follow?
IEC 62955, for AC charging stations (mode 3).
Which transformer goes with the module?
A measuring current transformer such as the CTBC17 with a 17 mm aperture, together with a type A residual current device.
What is the measuring range?
±300 mA with a resolution below 0.2 mA.
Similar equipment from other manufacturers