RCMB104 AC/DC residual current monitoring module for EV charging systems

The RCMB104 evaluates the signal from an external measuring current transformer and monitors AC and DC residual current in electric vehicle charging systems. Range is ±300 mA, with limit values to IEC 62752 or UL 2231-2. It mounts on the customer's own PCB.

Type
AC/DC sensitive residual current monitoring module
Measuring range
±300 mA
Residual current resolution
< 0.2 mA
Rated frequency
0…2000 Hz

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

On its own the module measures nothing: it needs an external measuring current transformer such as the CTBC17 and a type A RCD in the installation. Together they monitor fault current in AC charging systems for electric vehicles, where AC or DC fault currents can occur. Depending on the variant, the module is built into a charging unit (mode 2, IC-CPD) to IEC 62752 or UL 2231-2 (CCID5 or CCID20).

A patented measuring method gives the RMS value of the DC component of the residual current and of the AC component below the cut-off frequency. The measuring range is ±300 mA, resolution is below 0.2 mA and the rated frequency is 0…2000 Hz. Load current can be up to 32 A, or 80 A RMS single-phase where UL 2231-2 applies, or 3 x 32 A RMS three-phase.

Four outputs are provided: Switch1, Switch2, Error and PWM. Switch1 and Switch2 signal that a limit value has been exceeded. The limits depend on the variant and, together with a type A RCD, meet the trip requirements of IEC 62752 or UL 2231-2. The fault output is tied to integrated self-monitoring and test functions. Before every charging process the charge controller must check that the module works, and regular testing prevents long-term drift through an internal offset measurement.

Two variants are listed: RCMB104-1 (0…2000 Hz, IEC, 6/30 mA) and RCMB104-2 (0…2000 Hz, UL 2231, 5/20 mA). In IEC 62752 applications the module, combined with a type A RCD and a suitable switching device such as a power relay, can replace a type B RCD.

The module is soldered or plugged into the customer's PCB, with conductor tracks to the pins no longer than 100 mm. It is sold to makers of charging systems, not to end users. Supply is DC 5 V, operating temperature is -30 to 80 °C and protection is IP00.

Technical specifications

TypeAC/DC sensitive residual current monitoring module
Measuring range±300 mA
Residual current resolution< 0.2 mA
Rated frequency0…2000 Hz
Load current (single-phase)32 A (80 A) RMS
Load current (three-phase)3 x 32 A RMS
Rated operational voltage Ue230/400 V
Nominal supply voltage VccDC 5 V
Operating temperature-30…80 °C
Storage temperature-40…85 °C
Degree of protectionIP00
Rated impulse voltage4 kV
Rated insulation voltage Ui250 V
Overvoltage category / pollution degreeIII / 2
Maximal connection lengthup to 100 mm
OutputsSwitch1, Switch2, Error, PWM
VariantsRCMB104-1 (IEC 6/30 mA), RCMB104-2 (UL 2231 5/20 mA)

Part numbers

Show all part numbers (2)

B94042480, B94042481

How it compares with similar models

ParameterRCMB104 AC/DC residual current monitoring module for EV charging systemsRDC104-4 DC residual current monitoring module for AC charging stations to IEC 62955RCMB123 AC/DC differential current sensor for IC-CPD to IEC 62752RCMB121-2 AC/DC differential current sensor for IC-CPD to UL2231
TypeAC/DC sensitive residual current monitoring moduleDC sensitive residual current monitoring moduleDifferential current sensor, fluxgate with toroidal coreDifferential current sensor, fluxgate with toroidal core
Measuring range±300 mA±300 mA-300…+300 mA-300…+300 mA
OutputsSwitch1, Switch2, Error, PWMSwitch1, Switch2, Error, PWMOpen collectorOpen collector

Request a price and lead time

RCMB104 AC/DC residual current monitoring module for EV charging systems. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which variants of the RCMB104 exist?

RCMB104-1 with 6/30 mA limits to IEC and RCMB104-2 with 5/20 mA limits to UL 2231.

What does the module work with?

A measuring current transformer such as the CTBC17 and a type A residual current device.

What are the measuring range and resolution?

±300 mA with a resolution below 0.2 mA, over a rated frequency of 0…2000 Hz.