RDC125-5S differential current sensor for EV charging, 6 mA DC / 20 mA rms

The RDC125-5S senses DC and AC residual currents in electric vehicle charging circuits. It uses a fluxgate element with a toroidal core, mounts on a PCB and offers two open-collector outputs plus a UART interface.

Primary nominal RMS current (1 phase / 3 phase)
80 / 40 A
Rated residual operating current 1
6 mA DC
Rated residual operating current 2
20 mA rms
Max. measuring range (peak)
300 mA DC

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Wallboxes (Mode3) and personnel protection systems for electric vehicles to UL 2231 are the main uses of the RDC125-5S. It measures residual current in EV charging circuits and responds to both DC and AC fault currents, in stationary and mobile installations.

The sensing element is a fluxgate current sensor with a toroidal core. DC fault currents are detected to IEC 62955:2018, and AC and DC fault currents to UL 2231-2 Ed.2. Two open-collector digital outputs and a UART interface carry status and measured values. The package is compact, mounts on a printed circuit board and weighs 4.8 g.

On a 6 mA DC fault current, PIN 7 changes from a low level (GND) to a high-impedance state. On a 20 mA rms fault current, PIN 6 does the same. PIN 7 meets only the switch-off characteristic of IEC 62955, which covers the DC fault current. A load switch or circuit breaker needs an additional driver circuit. Primary nominal RMS current is 80 / 40 A for single-phase and three-phase use.

The maximum measuring range is 300 mA peak, resolution 2 µA, and the frequency range runs from DC to 2 kHz. Supply is 5 V DC at 21 mA rms. Clearance and creepage between primary and secondary are 8 mm each, built and tested to IEC 60664-1:2020. With insulated primary conductors the insulation coordination is reinforced insulation, material group 1, pollution degree 2 and overvoltage category III. Housing and bobbin material is UL-listed with flammability class 94V-0. Operating and storage temperature both span -40 to 85 °C.

Technical specifications

Primary nominal RMS current (1 phase / 3 phase)80 / 40 A
Rated residual operating current 16 mA DC
Rated residual operating current 220 mA rms
Max. measuring range (peak)300 mA DC
Resolution2 µA
Frequency rangeDC to 2 kHz
Ambient operating temperature-40…85 °C
Ambient storage temperature-40…85 °C
Mass4.8 g
Supply voltage5 V DC
Supply current21 mA rms
Clearance (primary to secondary)8 mm
Creepage (primary to secondary)8 mm

Part numbers

Show all part numbers (2)

T60404-N4641-X836, B94042450

How it compares with similar models

ParameterRDC125-5S differential current sensor for EV charging, 6 mA DC / 20 mA rmsRCMB104 AC/DC residual current monitoring module for EV charging systemsRCMB121-2 AC/DC differential current sensor for IC-CPD to UL2231RCMB130 AC/DC sensitive residual current monitoring module, ±100 mA, up to 32 A
Frequency rangeDC to 2 kHz—DC…2 kHzDC…2 kHz
Supply voltage5 V DC—5 V (4.8…5.2 V)DC 12…24 V

Request a price and lead time

RDC125-5S differential current sensor for EV charging, 6 mA DC / 20 mA rms. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What are the two trip thresholds?

PIN 7 changes state at 6 mA DC and PIN 6 at 20 mA rms.

What supply and outputs does the sensor have?

It runs from 5 V DC at 21 mA rms and has two open-collector outputs and a UART interface.

Can the sensor drive a breaker directly?

No. A load switch or circuit breaker to IEC 62955 / UL 2231 needs an additional driver circuit.