RDC121-5S fluxgate residual current sensor for AC charging stations
RDC121-5S is a fluxgate sensor with a toroidal core for PCB mounting. It picks up AC and DC residual current and switches open-collector outputs. Rated primary current is 80 A single-phase and 40 A three-phase.
- Type
- Differential current sensor, fluxgate with toroidal core
- Mounting
- PCB mounting
- Primary rated current (1 phase / 3 phase)
- 80 / 40 A
- Rated residual fault current 1
- 6 mA DC
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The RDC121-5S monitors residual current in AC charging equipment. It responds to both AC and DC current, which suits wallboxes and personnel protection systems for electric vehicles under UL2231.
The sensing element is a fluxgate with a toroidal core, and the sensor is soldered to a printed circuit board. Its outputs are open-collector types.
On a DC fault current above the 6 mA DC threshold, pin 3 goes from a low level (GND) to a high-impedance state. On an AC fault current above 20 mA rms, pin 4 changes state in the same way. DC faults are assessed to IEC 62955:2018 and AC faults to UL2231-2 Ed.2. Errors, including internal ones, are signalled on pin 1 (ERROR-OUT).
The sensor meets only the switch-off characteristic of IEC 62955, so it monitors residual current and does not interrupt the circuit itself. A separate switching device is needed. A driver connected to the outputs must stay within 40 V/50 mA.
Rated primary current is 80 A for one phase and 40 A for three phases. Trip tolerance is 4 mA DC and 14 mA rms. Supply voltage is 5 V DC, mass is 21 g and the operating and storage temperature range is -40 to 85 °C.
Where insulated primary conductors are used, insulation coordination follows IEC 60664-1:2020: reinforced insulation, insulation material group 1, pollution degree 2, overvoltage category III. Insulated wires are preferred.
Technical specifications
| Type | Differential current sensor, fluxgate with toroidal core |
|---|---|
| Mounting | PCB mounting |
| Primary rated current (1 phase / 3 phase) | 80 / 40 A |
| Rated residual fault current 1 | 6 mA DC |
| Rated residual fault current 2 | 20 mA rms |
| Trip tolerance 1 | 4 mA DC |
| Trip tolerance 2 | 14 mA rms |
| Outputs | Open collector |
| Supply voltage | 5 V DC |
| Mass | 21 g |
| Operating and storage temperature | -40…85 °C |
| Standards | IEC 62955:2018, UL2231-2 Ed.2 |
Part numbers
Show all part numbers (2)
T60404-N4641-X804, B94042448
How it compares with similar models
| Parameter | RDC121-5S fluxgate residual current sensor for AC charging stations | RCMB121-2 AC/DC differential current sensor for IC-CPD to UL2231 | RCMB123 AC/DC differential current sensor for IC-CPD to IEC 62752 | RDC104-4 DC residual current monitoring module for AC charging stations to IEC 62955 |
|---|---|---|---|---|
| Type | Differential current sensor, fluxgate with toroidal core | Differential current sensor, fluxgate with toroidal core | Differential current sensor, fluxgate with toroidal core | DC sensitive residual current monitoring module |
| Outputs | Open collector | Open collector | Open collector | Switch1, Switch2, Error, PWM |
| Supply voltage | 5 V DC | 5 V (4.8…5.2 V) | 5 V (4.8…5.2 V) | DC 5 V |
Request a price and lead time
RDC121-5S fluxgate residual current sensor for AC charging stations. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What residual current thresholds does the RDC121-5S use?
Rated residual fault current is 6 mA DC and 20 mA rms, with trip tolerances of 4 mA DC and 14 mA rms.
How does the sensor report an error?
Internal errors are signalled on pin 1 (ERROR-OUT), and the outputs are open-collector.
Does the sensor disconnect the circuit by itself?
No. It provides only the IEC 62955 switch-off characteristic by monitoring residual current, and a separate device does the switching.