RCMB123 AC/DC differential current sensor for IC-CPD to IEC 62752
The RCMB123 is a fluxgate differential current sensor with a toroidal core, mounted on a printed circuit board. It detects AC and DC fault currents and has open-collector outputs. It is aimed at mobile IC-CPD units to IEC 62752.
- Type
- Differential current sensor, fluxgate with toroidal core
- Mounting
- PCB mounting
- Rated residual operating current 1
- 6 mA DC
- Rated residual operating current 2
- 30 mA rms
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
A mobile charging cable needs a fault current monitor that sees DC as well as AC, and the RCMB123 is built for that job. It is used mainly in mobile equipment, in IC-CPD units covered by IEC 62752:2016.
The sensing element is a fluxgate with a toroidal core. The sensor is soldered to a PCB and uses AEC-Q qualified components. Its outputs are open-collector.
The pins show what the sensor has detected. A DC fault current takes pin 3 from a low level (GND) to high impedance. An AC fault current changes pins 3 and 4. Errors, including internal ones, are reported on pin 1 (ERROR-OUT), which goes to high impedance. The response time allows for the switching time of a standard relay, 20 ms.
Rated residual operating currents are 6 mA DC and 30 mA rms. The measuring range is -300 to +300 mA with a resolution below 0.2 mA, over a frequency range from DC to 2 kHz. Operating and storage temperature is -40 to 85 °C and the supply voltage is 5 V (4.8 to 5.2 V).
Insulation coordination follows IEC 60664-1:2007: reinforced insulation, insulation material group 1, pollution degree 3 and overvoltage category III. Clearance and creepage are 4.22 mm and 5.65 mm between primary conductors, and 6.53 mm and 7.75 mm between primary and secondary.
Technical specifications
| Type | Differential current sensor, fluxgate with toroidal core |
|---|---|
| Mounting | PCB mounting |
| Rated residual operating current 1 | 6 mA DC |
| Rated residual operating current 2 | 30 mA rms |
| Measuring range | -300…+300 mA |
| Resolution | < 0.2 mA |
| Frequency range | DC…2 kHz |
| Operating and storage temperature | -40…85 °C |
| Supply voltage | 5 V (4.8…5.2 V) |
| Outputs | Open collector |
| Standard | IEC 62752:2016 |
Part numbers
Show all part numbers (2)
B94042470, T60404-N4641-X920
How it compares with similar models
| Parameter | RCMB123 AC/DC differential current sensor for IC-CPD to IEC 62752 | RCMB121-2 AC/DC differential current sensor for IC-CPD to UL2231 | RDC121-5S fluxgate residual current sensor for AC charging stations | RDC104-4 DC residual current monitoring module for AC charging stations to IEC 62955 |
|---|---|---|---|---|
| Type | Differential current sensor, fluxgate with toroidal core | Differential current sensor, fluxgate with toroidal core | Differential current sensor, fluxgate with toroidal core | DC sensitive residual current monitoring module |
| Measuring range | -300…+300 mA | -300…+300 mA | — | ±300 mA |
| Supply voltage | 5 V (4.8…5.2 V) | 5 V (4.8…5.2 V) | 5 V DC | DC 5 V |
| Outputs | Open collector | Open collector | Open collector | Switch1, Switch2, Error, PWM |
| Standard | IEC 62752:2016 | UL2231-2 Ed.2 | — | IEC 62955 |
Request a price and lead time
RCMB123 AC/DC differential current sensor for IC-CPD to IEC 62752. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What equipment is the RCMB123 meant for?
Mobile charging units of the IC-CPD type that follow IEC 62752:2016.
What are the measuring range and resolution?
-300 to +300 mA with a resolution below 0.2 mA, from DC to 2 kHz.
How does the sensor signal a fault?
Pin 1 (ERROR-OUT) changes to a high-impedance state.
Similar equipment from other manufacturers