International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

RCMB123 AC/DC differential current sensor for IC-CPD to IEC 62752

The RCMB123 is a fluxgate differential current sensor with a toroidal core, mounted on a printed circuit board. It detects AC and DC fault currents and has open-collector outputs. It is aimed at mobile IC-CPD units to IEC 62752.

Type
Differential current sensor, fluxgate with toroidal core
Mounting
PCB mounting
Rated residual operating current 1
6 mA DC
Rated residual operating current 2
30 mA rms

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

A mobile charging cable needs a fault current monitor that sees DC as well as AC, and the RCMB123 is built for that job. It is used mainly in mobile equipment, in IC-CPD units covered by IEC 62752:2016.

The sensing element is a fluxgate with a toroidal core. The sensor is soldered to a PCB and uses AEC-Q qualified components. Its outputs are open-collector.

The pins show what the sensor has detected. A DC fault current takes pin 3 from a low level (GND) to high impedance. An AC fault current changes pins 3 and 4. Errors, including internal ones, are reported on pin 1 (ERROR-OUT), which goes to high impedance. The response time allows for the switching time of a standard relay, 20 ms.

Rated residual operating currents are 6 mA DC and 30 mA rms. The measuring range is -300 to +300 mA with a resolution below 0.2 mA, over a frequency range from DC to 2 kHz. Operating and storage temperature is -40 to 85 °C and the supply voltage is 5 V (4.8 to 5.2 V).

Insulation coordination follows IEC 60664-1:2007: reinforced insulation, insulation material group 1, pollution degree 3 and overvoltage category III. Clearance and creepage are 4.22 mm and 5.65 mm between primary conductors, and 6.53 mm and 7.75 mm between primary and secondary.

Technical specifications

TypeDifferential current sensor, fluxgate with toroidal core
MountingPCB mounting
Rated residual operating current 16 mA DC
Rated residual operating current 230 mA rms
Measuring range-300…+300 mA
Resolution< 0.2 mA
Frequency rangeDC…2 kHz
Operating and storage temperature-40…85 °C
Supply voltage5 V (4.8…5.2 V)
OutputsOpen collector
StandardIEC 62752:2016

Part numbers

Show all part numbers (2)

B94042470, T60404-N4641-X920

How it compares with similar models

ParameterRCMB123 AC/DC differential current sensor for IC-CPD to IEC 62752RCMB121-2 AC/DC differential current sensor for IC-CPD to UL2231RDC121-5S fluxgate residual current sensor for AC charging stationsRDC104-4 DC residual current monitoring module for AC charging stations to IEC 62955
TypeDifferential current sensor, fluxgate with toroidal coreDifferential current sensor, fluxgate with toroidal coreDifferential current sensor, fluxgate with toroidal coreDC sensitive residual current monitoring module
Measuring range-300…+300 mA-300…+300 mA—±300 mA
Supply voltage5 V (4.8…5.2 V)5 V (4.8…5.2 V)5 V DCDC 5 V
OutputsOpen collectorOpen collectorOpen collectorSwitch1, Switch2, Error, PWM
StandardIEC 62752:2016UL2231-2 Ed.2—IEC 62955

Request a price and lead time

RCMB123 AC/DC differential current sensor for IC-CPD to IEC 62752. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What equipment is the RCMB123 meant for?

Mobile charging units of the IC-CPD type that follow IEC 62752:2016.

What are the measuring range and resolution?

-300 to +300 mA with a resolution below 0.2 mA, from DC to 2 kHz.

How does the sensor signal a fault?

Pin 1 (ERROR-OUT) changes to a high-impedance state.