RC48C ground-fault and ground-continuity monitor
The RC48C combines residual current monitoring of 0.1…10 A with grounding conductor monitoring in one device. It suits trailing cables and cables with a pilot wire, and switches a relay with two changeover contacts.
- Rated insulation voltage
- AC 250 V
- Rated impulse voltage / pollution degree
- 2.5 kV / 3
- Supply voltage US
- AC/DC 60…264 V, 50…60 Hz
- Supply voltage US (for UL)
- AC/DC 110…240 V, 50/60 Hz
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Use the RC48C in (high-resistance) grounded AC systems. It is particularly suited to cables that feature a pilot wire and to trailing cable protection. Two functions share one housing: monitoring of the residual current, and monitoring of the grounding conductor for low resistance, high resistance and short circuit.
The residual current is measured through a residual current transformer, with all active conductors routed through it. The response value is adjustable over 0.1…1 A or 1…10 A and the response delay can be selected from 0.1…2 s. The "ALARM Ground Fault" LED lights when the limit is exceeded, and the alarm stays stored until the built-in or an external reset button is pressed.
For the ground check, the RC48C applies DC 12 V between contacts G and GC. A termination device E6… is connected on the load side to EGC and PW of the monitored cable. From the voltage drop across it the monitor recognises longitudinal faults (high resistance or break) and transverse faults (short circuit). The series resistance fault response value is 40 Ω, the rated current of the measuring loop DC 25 mA and the output impedance 240 Ω.
Supply is AC/DC 60…264 V, 50…60 Hz (AC/DC 110…240 V for UL), consuming about 5 VA at AC 60 V and 8.5 VA at AC 264 V. Rated insulation voltage is AC 250 V, rated impulse voltage 2.5 kV and pollution degree 3. Protection against extraneous voltage is AC 25 V continuous and AC 120 V for 3 s.
The relay has two voltage-free changeover contacts rated AC 250 V/DC 300 V, with a making capacity of AC/DC 5 A, a breaking capacity of 2/0.2 A on AC/DC and 12000 operating cycles. An RI2000GC remote alarm indicator can be added. Mounting is in standard distribution panels (DIN 43871), on DIN rail (DIN EN 50022) or by screws.
Technical specifications
| Rated insulation voltage | AC 250 V |
|---|---|
| Rated impulse voltage / pollution degree | 2.5 kV / 3 |
| Supply voltage US | AC/DC 60…264 V, 50…60 Hz |
| Supply voltage US (for UL) | AC/DC 110…240 V, 50/60 Hz |
| Power consumption | approx. 5 VA at AC 60 V; approx. 8.5 VA at AC 264 V |
| Response value, residual current | 0.1…1 A or 1…10 A |
| Response delay | 0.1…2 s |
| Continuous short-circuit current | 200…2500 A for 2 s |
| Response value, series resistance fault | 40 Ω |
| Open-circuit voltage | DC 12 V |
| Output impedance | 240 Ω |
| Rated current of the measuring loop | DC 25 mA |
| Protection against extraneous voltage | AC 25 V continuous; AC 120 V for 3 s |
| Rated contact voltage | AC 250 V/DC 300 V |
| Making capacity | AC/DC 5 A |
| Breaking capacity AC/DC | 2/0.2 A |
| Operating cycles | 12000 |
Part numbers
Show all part numbers (3)
RC48C-935 B94013002, RC48C-9935 B94013012, RC48C-9936 B94013013
Request a price and lead time
RC48C ground-fault and ground-continuity monitor. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What does the RC48C monitor?
The residual current through a residual current transformer, and the grounding conductor for low resistance, high resistance and short circuit.
What are the response value and delay ranges?
The response value is 0.1…1 A or 1…10 A, and the delay is 0.1…2 s.
What contacts does the output relay have?
Two voltage-free changeover contacts rated AC 250 V/DC 300 V, with a making capacity of AC/DC 5 A.
Similar equipment from other manufacturers