PEM series meters ALD1, ALE3, AWD3 with Modbus RTU and MID

The PEM series has a single-phase ALD1 for 32 A and three-phase ALE3 for 65 A and AWD3 for 6 A. All carry Modbus RTU, a 7-digit display, the MID mark and DIN rail mounting.

Model ALD1
1Ph/32 A, AC 230 V, 50 Hz, Iref = 5 A, Imax = 32 A
Model ALE3
3Ph/65 A, 3 x AC 230/400 V, 50 Hz, Iref = 10 A, Imax = 65 A
Model AWD3
3Ph/6 A, 3 x AC 230/400 V, 50 Hz, Iref = 5 A, Imax = 6 A
Transformer measurement (AWD3)
5…1500 A

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

PEM energy meters record active energy and also report current, voltage, power and cos (phi). Where a measuring point is used for billing, the MID (Measurement Instrument Directive) conformity mark shows that the calibration requirements are met. Every model has a Modbus RTU interface, a 7-digit display and DIN rail mounting.

The single-phase ALD1 runs on AC 230 V, 50 Hz with a reference current Iref of 5 A and a maximum current Imax of 32 A. Starting current Ist is 20 mA, minimum current Imin 0.25 A and active power consumption 0.4 W. The LC display counts at 2000 imp/kWh.

The three-phase ALE3 is supplied at 3 x AC 230/400 V, 50 Hz, with Iref 10 A, Imax 65 A, Ist 40 mA and Imin 0.5 A, using 0.4 W per phase; its LED pulses at 1000 imp/kWh. Terminals E1 and E2 take the control signal of a ripple control receiver to switch tariffs.

The three-phase AWD3 is fed through current transformers over a range of 5…1500 A. Iref is 5 A, Imax 6 A, Ist 10 mA and Imin 0.05 A, with conversion factors from 5:5 up to 1500:5. The supply is 3 x AC 230/400 V, 50 Hz.

Accuracy class is B to EN 50470-3 and 1 to IEC 62053-21, with a voltage tolerance of -20 %/+15 %. The backlit LC display has 6 mm digits and, without mains voltage, a capacitor-supported display lasts for a maximum of two periods of 10 days. Baud rate and parity are recognised automatically, readings can be reset and partial readings taken, and a lead seal can be fitted with a cap ordered as an accessory.

A four-fold S0 pulse counter, the PCD7, with Modbus RTU completes the range. Ordering numbers are B93101005…B93101008, with sealable covers B93101009 and B93101010.

Technical specifications

Model ALD11Ph/32 A, AC 230 V, 50 Hz, Iref = 5 A, Imax = 32 A
Model ALE33Ph/65 A, 3 x AC 230/400 V, 50 Hz, Iref = 10 A, Imax = 65 A
Model AWD33Ph/6 A, 3 x AC 230/400 V, 50 Hz, Iref = 5 A, Imax = 6 A
Transformer measurement (AWD3)5…1500 A
Accuracy classB acc. to EN 50470-3, 1 acc. to IEC 62053-21
Voltage tolerance-20 %/+15 %
Starting current Ist (ALD1 / ALE3 / AWD3)20 mA / 40 mA / 10 mA
Minimum current Imin (ALD1 / ALE3 / AWD3)0.25 A / 0.5 A / 0.05 A
Active power consumption0.4 W (per phase for ALE3 and AWD3)
Pulses2000 imp/kWh (ALD1), 1000 imp/kWh (ALE3)
InterfaceModbus RTU
Display7 digits, 6 mm high
MountingDIN rail

Part numbers

Show all part numbers (6)

B93101005, B93101006, B93101007, B93101008, B93101009, B93101010

Request a price and lead time

PEM series meters ALD1, ALE3, AWD3 with Modbus RTU and MID. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How do the ALD1, ALE3 and AWD3 differ?

The ALD1 is single-phase for 32 A, the ALE3 is three-phase for 65 A, and the AWD3 is three-phase for 6 A and connects through current transformers.

Can the meters be used for billing?

Yes, the models carry the MID conformity mark and accuracy class B to EN 50470-3.

What communication interface is fitted?

Modbus RTU, with automatic recognition of the bus transmission rate and parity.