PCS-9700 for renewables — SCADA for wind and solar plants, PCS-9726 pad-mount substation control units, generation forecasting and AGC/AVC
NR PCS-9700 for renewables is an automation package for wind and solar power plants. It includes the SCADA of the plant and its substation, the PCS-9726 protection and control units for the pad-mount substations of generator groups, the PCS-9700F generation forecast and the PCS-9700R automatic regulation of active and reactive power. The system works according to IEC 61850 and IEC 61131.
- PCS-9700 Renewable SCADA
- substation and renewable plant automation system, IEC 61850, IEC 61131
- PCS-9726A
- protection, control and communication of a block-type wind/solar pad-mount substation: overcurrent 50/51P, ground fault 50/51G, voltage 27/59, gas/process protection, ring switch
- PCS-9726A recording
- 64 operation reports, 64 waveforms, 1024 SOE events
- PCS-9700F
- power forecast by NWP, physical model and ANN; 2 servers (main/standby), weather data server
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The PCS-9700 Renewable Energy SCADA is built on the same principles as the PCS-9700 substation system. It collects and processes data in real time and performs sequential control of circuit breakers, disconnectors, OLTC and groups of compensating devices with synchro-check and interlocking. Communication with dispatch centers works independently of the local HMI. Time is synchronized by GPS and IRIG-B, and third-party devices are connected through IEC 61850 protocol converters. The system collects protection operation information and waveforms, and the logic is programmed according to IEC 61131.
The PCS-9726A protects, monitors and controls a block-type containerized pad-mount substation at a wind or solar plant in grids with any neutral grounding mode. The device has instantaneous and time-delayed overcurrent protections for phase, zero-sequence and negative-sequence currents, overvoltage and undervoltage protections and zero-sequence voltage protection. It receives the signals of the transformer's process protections, performs metering and controls the circuit breaker. Its memory holds 64 operation reports, 64 waveforms and 1024 events. The built-in communication manager and ring switch collect data from inverters, meters and other IEDs and pass it to the SCADA or RTU, so fewer separate devices are needed in the substation.
The PCS-9700F forecasts the output of the plant for the coming period. The source data comes from the numerical weather prediction NWP, from monitoring of the plant and the weather station (solar radiation, temperature, wind speed) and from statistics, and the calculation combines a physical model with artificial neural networks. The complex has two forecast servers, a main and a standby one, a weather data processing server and an engineer's web station. It is separated from the Internet by a reverse isolator, that is a unidirectional gateway, and from the substation network by a firewall.
The PCS-9700R automatically regulates generation (AGC) by frequency or power flows and voltage (AVC) through the plant's compensating devices according to the dispatcher's setpoints. Data on reserves and interlocks reaches the dispatch center in real time. The forecasting and regulation software runs on the SOPHIC platform, and the logic is configured by visual programming. The SCADA, forecasting and regulation work together, and the PCS-9726A in each substation passes to them the data of inverters, meters and other IEDs.
Technical specifications
| PCS-9700 Renewable SCADA | substation and renewable plant automation system, IEC 61850, IEC 61131 |
|---|---|
| PCS-9726A | protection, control and communication of a block-type wind/solar pad-mount substation: overcurrent 50/51P, ground fault 50/51G, voltage 27/59, gas/process protection, ring switch |
| PCS-9726A recording | 64 operation reports, 64 waveforms, 1024 SOE events |
| PCS-9700F | power forecast by NWP, physical model and ANN; 2 servers (main/standby), weather data server |
| PCS-9700R | plant AGC (active power/frequency) and AVC (voltage/reactive power) |
| Security | reverse isolator (unidirectional gateway) and firewall |
| Software platform | SOPHIC |
Request a price and lead time
PCS-9700 for renewables — SCADA for wind and solar plants, PCS-9726 pad-mount substation control units, generation forecasting and AGC/AVC. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8537 10 98 00 |
|---|---|
| HS, 6 digits | 8537 10 |
| CN (EU) | 8537 10 98 |
| HTSUS (USA) | 8537 10 91 70 |
| China customs tariff | 8537 10 90 90 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
What protections does the PCS-9726A pad-mount substation unit have?
Overcurrent protections for phase, zero-sequence and negative-sequence currents, voltage protections and reception of the transformer's process protection signals. The device stores 64 reports, 64 waveforms and 1024 events.
What data is the PCS-9700F generation forecast based on?
On the numerical weather prediction NWP, plant and weather station monitoring data, and statistics. The calculation combines a physical model with artificial neural networks.
What standards does the SCADA support?
Devices are integrated according to IEC 61850 and the logic is programmed according to IEC 61131. Time is synchronized by GPS and IRIG-B.
Similar equipment from other manufacturers