LINETRAXX® SmartDetect LCM410 Four-Channel Load Current Monitor, 6 mA…50 A
The LINETRAXX® SmartDetect LCM410 monitors AC and pulsed load currents on four channels in TN, TT and IT networks. Main alarm threshold 6 mA…50 A, frequency range 42 Hz…20 kHz, supply DC 24 V.
- Type
- Four-channel load current monitor
- Supply voltage
- DC 24 V
- Frequency range
- 42 Hz…20 kHz
- Measuring range (peak)
- 3 mA…100 A
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Four feeders, one 1 DU housing. The LINETRAXX® SmartDetect LCM410 watches alternating and pulsating load currents on four independent channels in TN, TT and IT networks, over a frequency range of 42 Hz…20 kHz. The measuring range is 3 mA…100 A (peak) or 2 mA…70 A (rms).
Each channel is evaluated for AC rms and pulsed current and triggers a pre-warning and a main alarm at adjustable thresholds. The main alarm ILn is set between 6 mA…50 A (factory setting 16 A) and the pre-warning between 10…100 % x ILn (70 %). Operating uncertainty is ±10 % at 0.5…5 x ILn, and the rated response load current is 50 A.
Permissible continuous load current depends on how many channels are in use: 85 A on one channel, 60 A on two, 49 A on three and 42 A on four. The supply is DC 24 V with a power consumption of up to 2 W, and the operating temperature is -40…+85 °C.
Parameters are set from the Connect app over NFC (13.56 MHz) or over RS-485 using Modbus RTU at up to 115.2 kbits/s. Cable length is limited to 1200 m at 9.6 kbits/s, and the device address runs from 1…247. The unit also offers digital input I, digital input/output Q and a multifunctional digital/analogue output M+.
The polycarbonate enclosure (flammability class UL94 V-0) clips onto a DIN rail to IEC 60715 and weighs no more than 55 g. Terminals are IP20 and internal components IP30. The device was developed to DIN EN IEC 61010-1 and UL508, with EU and UKCA declarations of conformity. A sealable transparent cover (B80609199), STEP-PS/1 power supplies and CTAC, CTAS, W, WR and WS current transformers are listed as options.
Technical specifications
| Type | Four-channel load current monitor |
|---|---|
| Supply voltage | DC 24 V |
| Frequency range | 42 Hz…20 kHz |
| Measuring range (peak) | 3 mA…100 A |
| Measuring range rms | 2 mA…70 A |
| Rated response load current | 50 A |
| Main alarm threshold ILn | 6 mA…50 A (16 A) |
| Pre-warning | 10…100 % x ILn (70 %) |
| Operating uncertainty | ±10 % (at 0.5…5 x ILn) |
| Continuous load current, 1 / 2 / 3 / 4 channels | 85 A / 60 A / 49 A / 42 A |
| Power consumption | ≤ 2 W |
| Interfaces | RS-485 (Modbus RTU), NFC |
| Degree of protection | IP20 (terminals), IP30 (internal components) |
| Weight | ≤ 55 g |
| Operating temperature | -40…+85 °C |
Part numbers
Show all part numbers (5)
B85604049, B80609199, B94053110, B94053111, B94053112
How it compares with similar models
| Parameter | LINETRAXX® SmartDetect LCM410 Four-Channel Load Current Monitor, 6 mA…50 A | LINETRAXX® SmartDetect RCMS410/RCMS425 four-channel residual current monitor | LINETRAXX® SmartDetect MRCDB425 AC/DC sensitive modular residual current device | LINETRAXX® CEP410R-2 residual current monitor for the central earthing point |
|---|---|---|---|---|
| Supply voltage | DC 24 V | DC 24 V; AC/DC 100…240 V | DC 24 V; AC/DC 100…240 V | DC 24 V; AC/DC 100…240 V |
| Frequency range | 42 Hz…20 kHz | 15 Hz…20 kHz | DC, 15 Hz…20 kHz | 42…70 Hz |
| Measuring range (peak) | 3 mA…100 A | 3 mA…100 A | 3 mA…28 A | — |
| Measuring range rms | 2 mA…70 A | 2 mA…70 A | 2 mA…20 A | — |
| Degree of protection | IP20 (terminals), IP30 (internal components) | — | IP20 | IP20 |
| Weight | ≤ 55 g | ≤ 55 g | ≤ 125 g | ≤ 100 g |
Request a price and lead time
LINETRAXX® SmartDetect LCM410 Four-Channel Load Current Monitor, 6 mA…50 A. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How are the thresholds set on the LCM410?
From the Connect app over NFC, or over RS-485 with Modbus RTU. The main alarm ILn is adjustable between 6 mA…50 A.
What continuous current is allowed with several channels in use?
85 A on one channel, 60 A on two, 49 A on three and 42 A on four.
How long may the RS-485 line be?
Up to 1200 m at 9.6 kbits/s; the baud rate goes up to 115.2 kbits/s and the device address is 1…247.