LINETRAXX® MRCDB300 AC/DC sensitive residual current monitoring module for MRCD
MRCDB300 modules act as additional protection in earthed TN and TT systems up to 800 V within an MRCD arrangement. They are AC/DC sensitive over DC…100 kHz and provide two changeover contacts and RS-485 with Modbus RTU.
- Supply voltage
- DC 24 V (19.2…28.8 V)
- Frequency range
- DC…100 kHz
- Detection type
- AC/DC sensitive, type B+ to VDE 0664-400
- Switch-off time
- 20 ms
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Within an MRCD arrangement, the MRCDB300 module monitors residual current in earthed TN and TT systems up to 800 V as additional protection. It detects AC/DC residual current as type B+ to VDE 0664-400 over DC…100 kHz, with an accuracy of ±1 % of full scale.
Four versions exist. MRCDB301 covers protection of persons and MRCDB302 covers fire protection. MRCDB303 is freely configurable for protection of persons, fire protection and plant protection. MRCDB305 protects persons where pulsed, very high peak load currents occur (above 1 kA for less than 1 s), such as in welding applications.
The supply is DC 24 V (19.2…28.8 V) and the switch-off time is 20 ms. Operating deviation is ±17.5 % and response uncertainty 0…–35 %. Two changeover contacts switch AC 250 V / 250 V at 5 A / 3 A, or DC 220 / 110 / 24 V at 0.1 / 0.2 / 1 A, with a minimum current of 10 mA at DC 5 V. Data pass over RS-485 with Modbus RTU.
The module works with CTBC measuring current transformers of 20, 35, 60, 120 and 210 mm internal diameter. Overall size depends on the transformer: 74 x 112 x 37 mm with CTBC20(P), 97 x 130 x 47 mm with CTBC35(P), 126 x 158 x 57 mm with CTBC60(P), 188 x 232 x 96 mm with CTBC120(P) and 302 x 346 x 153 mm with CTBC210(P). Thermal rated continuous differential current Icth is 30 A, short-time current Ith 2.4 kA / 1 s and impulse current Idyn 6 kA / 40 ms.
The series is built to IEC 60947-2, IEC 60364-5-53, IEC 60755, VDE 0664-400 and DIN EN 45545-2:2016. Accessories include a USB to RS-485 interface converter, a terminal block for the MRCD module and snap-on mounting for CTBC20(P) and CTBC35(P).
Technical specifications
| Supply voltage | DC 24 V (19.2…28.8 V) |
|---|---|
| Frequency range | DC…100 kHz |
| Detection type | AC/DC sensitive, type B+ to VDE 0664-400 |
| Switch-off time | 20 ms |
| Measuring accuracy | ±1 % of full scale |
| Operating deviation | ±17.5 % |
| Response uncertainty | 0…–35 % |
| Thermal rated continuous differential current Icth | 30 A |
| Thermal rated short-time current Ith | 2.4 kA / 1 s |
| Rated impulse current Idyn | 6 kA / 40 ms |
| Output | 2 changeover contacts |
| Switching AC | 250 V / 250 V; 5 A / 3 A |
| Switching DC | 220 / 110 / 24 V; 0.1 / 0.2 / 1 A |
| Minimum current | 10 mA at DC 5 V |
| Interface | RS-485, Modbus RTU |
| CTBC internal diameter | 20, 35, 60, 120, 210 mm |
Part numbers
Show all part numbers (20)
B74043120, B74043121, B74043122, B74043125, B98120001, B98120002, B98120003, B98120004, B98120005, B98120006, B98120007, B98120020, B98120008, B98120021, B95012045, B74043124, B91080111, B91080112, B94053111, B94053112
How it compares with similar models
| Parameter | LINETRAXX® MRCDB300 AC/DC sensitive residual current monitoring module for MRCD | LINETRAXX® RCMB300 residual current monitoring module for AC and DC, up to 20 A | LINETRAXX® RCMB330 AC/DC sensitive residual current monitoring module, 10…500 mA, RS-485 | LINETRAXX® RCMS460-D residual current monitor for earthed systems, 12 channels |
|---|---|---|---|---|
| Frequency range | DC…100 kHz | DC…100 kHz | DC…100 kHz | 0…2000 Hz, 42…2000 Hz |
| Interface | RS-485, Modbus RTU | RS-485, Modbus RTU | — | RS-485 |
Request a price and lead time
LINETRAXX® MRCDB300 AC/DC sensitive residual current monitoring module for MRCD. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How do MRCDB301, 302, 303 and 305 differ?
MRCDB301 protects persons and MRCDB302 gives fire protection. MRCDB303 combines both with plant protection, and MRCDB305 is built for pulsed loads with peaks above 1 kA for less than 1 s.
What are the switch-off time and frequency range?
The switch-off time is 20 ms and the frequency range is DC…100 kHz, with type B+ detection to VDE 0664-400.
Which CTBC transformers connect to the module?
CTBC20, CTBC35, CTBC60, CTBC120 and CTBC210, with internal diameters of 20, 35, 60, 120 and 210 mm respectively.