ISOMETER® isoHR1685DW-925 insulation monitor for elevating work platforms, AC 0…1000 V / DC 0…1500 V
The isoHR1685DW-925 is fitted to mobile, insulated elevating work platforms and continuously monitors insulation in systems up to DC 1500 V. It measures high-resistance faults of 100 kΩ…20 GΩ and offers RS-485 with BMS and Modbus RTU.
- Purpose
- Insulation monitoring of mobile insulated elevating work platforms
- Nominal system voltage Un
- AC 0…1000 V, DC 0…1500 V
- Supply voltage Us
- DC 18…30 V
- High-resistance insulation fault measurement
- 100 kΩ…20 GΩ
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The isoHR1685DW-925 is installed in mobile, insulated elevating work platforms and in overhead line vehicles. It monitors the insulation level of systems of AC 0…1000 V, DC 0…1500 V continuously, also during operation, to protect operatives from electrocution. It is also used for ungrounded work platforms in the chemical and electrochemical industries, for example at industrial water hydrogen electrolysers.
The AMPPlus measuring method adapts automatically to high leakage capacitance against earth, 0…2000 µF. High-resistance insulation faults are measured over 100 kΩ…20 GΩ, and the 925 version has a response range of 100 kΩ…100 MΩ. Response values Ran1 (Alarm 1) and Ran2 (Alarm 2) are set separately. An alarm is given when insulation falls below the threshold during approach, and before and during maintenance work.
A history memory with real-time clock stores 1023 alarm messages with date and time. The insulation resistance can be plotted against time (isoGraph). RS-485 with BMS and Modbus RTU forwards data, alarms and acknowledgements. Three changeover contacts K1, K2 and K3, freely programmable digital inputs, connection monitoring and an automatic self-test with fault message are fitted.
Supply is DC 18…30 V and the system frequency range is DC 0.1…460 Hz. The permissible extraneous DC voltage Ufg is ≤ DC 1600 V and the internal DC resistance Ri ≥ 70 kΩ. Rated impulse voltage is 10 kV, rated insulation voltage 1500 V, overvoltage category III and routine test voltage 2.2 kV. Built-in components and terminals are rated IP30.
Dimensions are 246 × 125 × 61.8 mm and the device is mounted vertically. It follows IEC 61010-1, IEC 61326-2-4, IEC 60664-1 and IEC 60947-5-1, with an EU declaration of conformity and UKCA.
Technical specifications
| Purpose | Insulation monitoring of mobile insulated elevating work platforms |
|---|---|
| Nominal system voltage Un | AC 0…1000 V, DC 0…1500 V |
| Supply voltage Us | DC 18…30 V |
| High-resistance insulation fault measurement | 100 kΩ…20 GΩ |
| Response range of version 925 | 100 kΩ…100 MΩ |
| System leakage capacitance Ce | 0…2000 µF |
| Frequency range of Un | DC 0.1…460 Hz |
| Rated impulse voltage | 10 kV |
| Rated insulation voltage | 1500 V |
| Overvoltage category (OVC) | III |
| Internal DC resistance Ri | ≥ 70 kΩ |
| Degree of protection | IP30 |
| Interface | RS-485, BMS, Modbus RTU |
| Dimensions | 246 × 125 × 61.8 mm |
Part numbers
Show all part numbers (1)
B91065806W
How it compares with similar models
| Parameter | ISOMETER® isoHR1685DW-925 insulation monitor for elevating work platforms, AC 0…1000 V / DC 0…1500 V | ISOMETER® isoPV1685DP insulation monitor for PV and BESS, AC 0…1000 V / DC 0…1500 V | ISOMETER® isoPV1685RTU/isoPV1685P insulation monitoring for PV systems up to AC 1000 V / DC 1500 V | ISOMETER® isoNAV685-D insulation monitoring device for IT systems, AC 0…690 V, DC 0…1000 V |
|---|---|---|---|---|
| Nominal system voltage Un | AC 0…1000 V, DC 0…1500 V | — | AC 0…1000 V, DC 0…1500 V | AC 0…690 V; 1…460 Hz / DC 0…1000 V |
| Supply voltage Us | DC 18…30 V | DC 18…30 V | DC 18…30 V | AC 24…240 V; 50…400 Hz / DC 24…240 V |
| Rated impulse voltage | 10 kV | — | 10 kV | 8 kV |
Request a price and lead time
ISOMETER® isoHR1685DW-925 insulation monitor for elevating work platforms, AC 0…1000 V / DC 0…1500 V. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What system voltage does the isoHR1685DW-925 monitor?
AC 0…1000 V and DC 0…1500 V.
How many alarms does the history memory hold?
1023 alarm messages with date and time.
Which interfaces does the device have?
RS-485 with BMS and Modbus RTU, three changeover contacts K1, K2 and K3, and freely programmable digital inputs.