ISOMETER® isoNAV685-D insulation monitoring device for IT systems, AC 0…690 V, DC 0…1000 V

The isoNAV685-D monitors insulation in IT AC systems with galvanically connected rectifiers and inverters. Response values 1 kΩ…10 MΩ, instantaneous tripping within 150 ms, Modbus TCP and a web server.

Nominal system voltage Un
AC 0…690 V; 1…460 Hz / DC 0…1000 V
Supply voltage Us
AC 24…240 V; 50…400 Hz / DC 24…240 V
Response value Ran1 (Alarm 1)
1 kΩ…10 MΩ
Response value Ran2 (Alarm 2)
20 V…1 kV

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The isoNAV685-D watches the insulation resistance of IT AC systems that contain galvanically connected rectifiers and inverters. The nominal system voltage is AC 0…690 V; 1…460 Hz and DC 0…1000 V, and the supply is AC 24…240 V; 50…400 Hz / DC 24…240 V.

It measures insulation resistance and the DC offset voltage and raises an alarm on a fault. Response value Ran1 (Alarm 1) is adjustable from 1 kΩ to 10 MΩ and Ran2 (Alarm 2) covers 20 V…1 kV. The device adapts automatically to the system leakage capacitance. For a DC residual voltage above 1.1 x UDC and Alarm 1 the response time tan is at most 150 ms; at RF = 0.5 x Ran (Ran = 10 kΩ) and Ce = 1 μF it is typically 4 s.

A high-resolution graphical LC display shows the values and the history memory has a real-time clock. Communication runs over RS-485 and Ethernet with Modbus TCP, BCOM and a web server. Configurable digital inputs (for example Test and Reset), a configurable digital output and a configurable analogue output for a measuring instrument are fitted, plus 2 changeover contacts. The minimum contact rating is 1 mA at AC/DC ≥ 10 V and the electrical endurance is 10000 cycles.

The device is used in AC/DC main circuits with directly connected DC components such as rectifiers, converters and variable-speed drives, and in systems containing switched-mode power supplies or frequency inverters.

Overvoltage category OVC III, rated impulse voltage 8 kV, rated insulation voltage 1000 V, pollution degree 3 (Un < 690 V) and 2 (Un < 1000 V), routine voltage test AC 2,2 kV. Power consumption is ≤12 W/21 VA. Internal components have IP40 protection and the terminals IP20; the enclosure measures 108 x 93 x 110 mm. Approvals are TÜV and UKCA, and standards include IEC 61557-8, IEC 60664-1/-3, IEC 61010-1, EN50121-3-2 and EN50121-4.

Technical specifications

Nominal system voltage UnAC 0…690 V; 1…460 Hz / DC 0…1000 V
Supply voltage UsAC 24…240 V; 50…400 Hz / DC 24…240 V
Response value Ran1 (Alarm 1)1 kΩ…10 MΩ
Response value Ran2 (Alarm 2)20 V…1 kV
Response time tan (DC residual voltage > 1.1 x UDC, Alarm 1)max. 150 ms
Response time tan (RF = 0.5 x Ran, Ran = 10 kΩ, Ce = 1 μF)typ. 4 s
Rated impulse voltage8 kV
Overvoltage category (OVC)III
Power consumption (50/60 Hz)≤12 W/21 VA
Switching elements2 changeover contacts
Electrical endurance10000 cycles
InterfacesRS-485, Ethernet, web server
ProtocolsModbus TCP, BCOM
Dimensions108 x 93 x 110 mm

Part numbers

Show all part numbers (4)

B91067014, kits B91067901, B91067902, B91067903

How it compares with similar models

ParameterISOMETER® isoNAV685-D insulation monitoring device for IT systems, AC 0…690 V, DC 0…1000 VISOMETER® isoRW685W-D-B railway insulation monitoring device for IT systems, AC 0…690 V, DC 0…1000 VISOMETER® isoRW685W-D insulation monitoring device for rolling stock IT systems, AC 0…690 V, DC 0…1000 VISOMETER® iso685 insulation monitoring device for IT systems, AC up to 690 V and DC up to 1000 V
Nominal system voltage UnAC 0…690 V; 1…460 Hz / DC 0…1000 VAC 0…690 V; DC 0…1000 VAC 0…690 V; DC 0…1000 VAC 0…690 V; 1…460 Hz / DC 0…1000 V
InterfacesRS-485, Ethernet, web serverRS-485, Ethernet, web serverRS-485, Ethernet, web serverRS-485, Ethernet (RJ45)
ProtocolsModbus TCP, BCOMModbus RTU, Modbus TCPModbus RTU, Modbus TCP, BCOM, BS bus, isoDataModbus TCP, Modbus RTU, BCOM, BS bus, isoData

Request a price and lead time

ISOMETER® isoNAV685-D insulation monitoring device for IT systems, AC 0…690 V, DC 0…1000 V. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What system voltage does the isoNAV685-D monitor?

AC 0…690 V; 1…460 Hz or DC 0…1000 V, including systems with rectifiers and inverters.

How fast does it trip?

For a DC residual voltage above 1.1 x UDC and Alarm 1 the response time is at most 150 ms; at RF = 0.5 x Ran (Ran = 10 kΩ) and Ce = 1 μF it is typically 4 s.

What outputs and interfaces does it have?

2 changeover contacts, a digital and an analogue output, and RS-485 and Ethernet with Modbus TCP, BCOM and a web server.