ISOMETER® isoNAV685-D-B offline insulation monitoring device for switched-off loads
The isoNAV685-D-B measures the insulation resistance of loads and systems while they are switched off. Response value 1 kΩ…10 MΩ, leakage capacitance up to 150 μF, Modbus TCP, web server and a graphical display.
- Supply voltage Us
- AC 24…240 V; 50…400 Hz / DC 24…240 V
- Rated insulation voltage
- 1000 V
- Response value Ran
- 1 kΩ…10 MΩ
- Response value Ran (factory setting)
- 50 kΩ
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The isoNAV685-D-B is made for offline monitoring: it measures the insulation resistance of loads and de-energised TN, TT or IT systems while they are switched off. The rated insulation voltage is 1000 V and the supply is AC 24…240 V; 50…400 Hz / DC 24…240 V.
It checks the L1, L2 and L3 coupling paths one after another, so a fault can be measured and located. Three insulation levels are monitored, using a reduced measuring voltage. An alarm is raised when the resistance falls below the preset response value, which is adjustable from 1 kΩ to 10 MΩ (factory setting 50 kΩ) with a response time of 30 s. The device adapts automatically to the system leakage capacitance, up to a maximum of 150 μF.
A high-resolution graphical LC display shows the current values and the history memory has a real-time clock. Communication uses RS-485 and Ethernet with Modbus TCP, BCOM and a web server. There are 3 digital inputs, 2 digital outputs and 1 analogue output.
The device connects to a 3(N)AC system, or to a frequency converter for monitoring in the off state. Internal components have IP40 protection and the terminals IP20. The enclosure measures 108 x 93 x 54 mm and mounts on a DIN rail or with screws.
Standards include IEC 61557-8, IEC 60664-1, IEC 61010-1, IEC 60947-5-1, IEC 61326-2-4, IEC 60364-4-43:2008 and DIN VDE 0100-430. Approvals are TÜV and UKCA. Terminal kits B91067901 (screw) and B91067902 (push-wire) and enclosure accessories B91067903 (terminal cover, 2 mounting clips) are ordered separately.
Technical specifications
| Supply voltage Us | AC 24…240 V; 50…400 Hz / DC 24…240 V |
|---|---|
| Rated insulation voltage | 1000 V |
| Response value Ran | 1 kΩ…10 MΩ |
| Response value Ran (factory setting) | 50 kΩ |
| Response time tan | 30 s |
| Maximum permissible system leakage capacitance | 150 μF |
| Inputs/outputs | 3 DI, 2 DO, 1 AO |
| Interfaces | RS-485, Ethernet, web server |
| Protocols | Modbus TCP, BCOM |
| Degree of protection, internal components | IP40 |
| Degree of protection, terminals | IP20 |
| Dimensions | 108 x 93 x 54 mm |
Part numbers
Show all part numbers (4)
B91067024, kits B91067901, B91067902, B91067903
How it compares with similar models
| Parameter | ISOMETER® isoNAV685-D-B offline insulation monitoring device for switched-off loads | ISOMETER® isoNAV685-D insulation monitoring device for IT systems, AC 0…690 V, DC 0…1000 V | ISOMETER® isoRW685W-D insulation monitoring device for rolling stock IT systems, AC 0…690 V, DC 0…1000 V | ISOMETER® isoRW685W-D-B railway insulation monitoring device for IT systems, AC 0…690 V, DC 0…1000 V |
|---|---|---|---|---|
| Inputs/outputs | 3 DI, 2 DO, 1 AO | — | 3 DI, 2 DO, 1 AO | 3 digital inputs, 2 digital outputs, 1 analogue output |
| Protocols | Modbus TCP, BCOM | Modbus TCP, BCOM | Modbus RTU, Modbus TCP, BCOM, BS bus, isoData | Modbus RTU, Modbus TCP |
Request a price and lead time
ISOMETER® isoNAV685-D-B offline insulation monitoring device for switched-off loads. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What does the isoNAV685-D-B monitor?
The insulation resistance of loads and TN, TT or IT systems in the switched-off state (offline).
What is the response value range?
1 kΩ…10 MΩ, with a factory setting of 50 kΩ and a response time of 30 s.
How much leakage capacitance is permitted?
Up to 150 μF; the device adapts to it automatically.