ISOMETER® isoRW685W-D-B railway insulation monitoring device for IT systems, AC 0…690 V, DC 0…1000 V

The isoRW685W-D-B monitors insulation resistance in IT AC systems with galvanically connected rectifiers and converters and in IT DC systems. It is made especially for railway applications and tested to DIN EN 50155, with response values of 1 kΩ…10 MΩ.

Nominal system voltage Un
AC 0…690 V; DC 0…1000 V
Supply voltage Us
AC 24…240 V; 50…400 Hz / DC 24…240 V
Response value Ran1 (ALARM 1)
1 kΩ…10 MΩ
Response value Ran2 (ALARM 2)
1 kΩ…10 MΩ

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The isoRW685W-D-B is an insulation monitoring device for IT AC systems with galvanically connected rectifiers and converters and for IT DC systems, made especially for railway applications. It is tested to DIN EN 50155 and works in AC, 3(N)AC, AC/DC and DC systems, with a nominal system voltage of AC 0…690 V and DC 0…1000 V.

A measuring current in the µA range is superimposed on the unearthed main circuit, and an alarm is raised when the insulation resistance drops below the preset response value. The device adapts automatically to the system leakage capacitance and offers two separately adjustable response value ranges, Ran1 and Ran2, each 1 kΩ…10 MΩ.

A graphical LC display (127 x 127 pixels, 40 x 40 mm) shows the isoGraph view, and the history memory with real-time clock buffers 13 days. Settings can be changed remotely over the Internet or an intranet through the web server or a COMTRAXX® gateway. RS-485/BS carries Modbus RTU and BCOM, and Ethernet carries Modbus TCP. The device has 3 digital inputs, 2 digital outputs and 1 analogue output.

Typical applications are AC, DC and AC/DC main circuits, UPS and battery systems, heaters with phase control, systems with switched-mode power supplies and IT systems with high leakage capacitance. Coupling devices AGH150W-4, AGH204S-4, AGH520S and AGH676S-4 extend the voltage range.

Supply is AC 24…240 V; 50…400 Hz / DC 24…240 V and the operating temperature is −40…+70 °C. The enclosure measures 108 × 93 × 110 mm, weighs under 390 g and mounts on a DIN rail or with screws. Standards include IEC 61557-8, DIN EN 50155, DIN EN 45545-2, DIN EN 50121-3-2, IEC 60664-1/-3 and IEC 61010-1. Approvals are TÜV and UKCA.

Technical specifications

Nominal system voltage UnAC 0…690 V; DC 0…1000 V
Supply voltage UsAC 24…240 V; 50…400 Hz / DC 24…240 V
Response value Ran1 (ALARM 1)1 kΩ…10 MΩ
Response value Ran2 (ALARM 2)1 kΩ…10 MΩ
Displaygraphical, 127 x 127 pixels, 40 x 40 mm
Inputs/outputs3 digital inputs, 2 digital outputs, 1 analogue output
InterfacesRS-485, Ethernet, web server
ProtocolsModbus RTU, Modbus TCP
Operating temperature−40…+70 °C
Dimensions (W × H × D)108 × 93 × 110 mm
Weight< 390 g

Part numbers

Show all part numbers (4)

B91067022W, kits B91067901, B91067902, B91067903

How it compares with similar models

ParameterISOMETER® isoRW685W-D-B railway insulation monitoring device for IT systems, AC 0…690 V, DC 0…1000 VISOMETER® isoRW685W-D insulation monitoring device for rolling stock IT systems, AC 0…690 V, DC 0…1000 VISOMETER® isoHR685W high-resistance insulation monitoring device up to 10 GΩ, IT systems AC 0…1000 V, DC 0…1300 VISOMETER® iso685-…-B insulation monitoring device for IT systems, AC 0…690 V, DC 0…1000 V
Nominal system voltage UnAC 0…690 V; DC 0…1000 VAC 0…690 V; DC 0…1000 VAC 0…1000 V; 0.1…460 Hz / DC 0…1300 V—
Response value Ran1 (ALARM 1)1 kΩ…10 MΩ1 kΩ…10 MΩ1 kΩ…3 GΩ—
Response value Ran2 (ALARM 2)1 kΩ…10 MΩ1 kΩ…10 MΩ1 kΩ…3 GΩ—
Inputs/outputs3 digital inputs, 2 digital outputs, 1 analogue output3 DI, 2 DO, 1 AO3 digital inputs, 2 digital outputs, 1 analogue output3 digital inputs, 2 digital outputs, 1 analogue output
InterfacesRS-485, Ethernet, web serverRS-485, Ethernet, web serverRS-485, Ethernet, BCOM, BS busRS-485, Ethernet
ProtocolsModbus RTU, Modbus TCPModbus RTU, Modbus TCP, BCOM, BS bus, isoDataModbus RTU, Modbus TCPModbus TCP, Modbus RTU, BCOM, isoData

Request a price and lead time

ISOMETER® isoRW685W-D-B railway insulation monitoring device for IT systems, AC 0…690 V, DC 0…1000 V. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which systems is the isoRW685W-D-B made for?

IT AC systems with galvanically connected rectifiers and converters and IT DC systems in railway applications, up to AC 0…690 V and DC 0…1000 V.

What interfaces and protocols does it have?

RS-485/BS with Modbus RTU and BCOM, Ethernet with Modbus TCP, and a web server for remote settings.

What are the response value ranges?

Two separately adjustable values, Ran1 and Ran2, each within 1 kΩ…10 MΩ.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides