ISOMETER® iso685 insulation monitoring device for IT systems, AC up to 690 V and DC up to 1000 V
Insulation monitoring device for AC IT systems of 0…690 V and DC IT systems of 0…1000 V. Response values 1 kΩ…10 MΩ, RS-485 and Ethernet interfaces, and Modbus TCP, Modbus RTU, BCOM, BS bus and isoData protocols. Available with display (D) or without (S).
- Nominal system voltage Un
- AC 0…690 V; 1…460 Hz / DC 0…1000 V
- Supply voltage Us
- AC 24…240 V; 50…400 Hz / DC 24…240 V
- Response value Ran1 (ALARM 1)
- 1 kΩ … 10 MΩ
- Response value Ran2 (ALARM 2)
- 1 kΩ … 10 MΩ
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
AC IT systems with galvanically connected rectifiers and inverters, and DC IT systems, are the field of the ISOMETER® iso685, which monitors their insulation resistance. The nominal system voltage Un is AC 0…690 V, 1…460 Hz / DC 0…1000 V, and the supply voltage Us is AC 24…240 V, 50…400 Hz / DC 24…240 V.
The response values Ran1 (ALARM 1) and Ran2 (ALARM 2) are adjustable from 1 kΩ to 10 MΩ. The device includes a web server, RS-485 and Ethernet (RJ45) interfaces, a current output of 0(4)…20 mA, voltage outputs of 0…10 V and 2…10 V, three digital inputs and two digital outputs. It speaks Modbus TCP, Modbus RTU, BCOM, BS bus and isoData.
The versions differ in equipment. The iso685-D has an integrated graphic LC display with controls and cannot be combined with the FP200. The iso685-S has no display and is operated from the FP200 front panel (iso685-S + FP200). Versions marked W (iso685W-D, iso685W-S + FP200W) carry Option W for extreme climatic and mechanical conditions (3K23, 3M12).
Operating temperature is −25…+55 °C, or −40…+70 °C with Option W, at altitudes up to 3000 m AMSL. Weight is under 390 g. Mounting is on a DIN rail to IEC 60715 or by screws.
Order codes: B91067010, B91067010W, B91067210, B91067210W, B91067110, B91067110W. Accessories: a set of screw terminals B91067901, a set of push-wire terminals B91067902, and enclosure accessories (terminal cover, two mounting clips) B91067903.
Technical specifications
| Nominal system voltage Un | AC 0…690 V; 1…460 Hz / DC 0…1000 V |
|---|---|
| Supply voltage Us | AC 24…240 V; 50…400 Hz / DC 24…240 V |
| Response value Ran1 (ALARM 1) | 1 kΩ … 10 MΩ |
| Response value Ran2 (ALARM 2) | 1 kΩ … 10 MΩ |
| Interfaces | RS-485, Ethernet (RJ45) |
| Analogue outputs | Current 0(4)…20 mA; voltage 0…10 V, 2…10 V |
| Digital inputs / outputs | 3 / 2 |
| Protocols | Modbus TCP, Modbus RTU, BCOM, BS bus, isoData |
| Operating temperature | −25…+55 °C |
| Operating temperature (Option W) | −40…+70 °C |
| Altitude | ≤ 3000 m AMSL |
| Weight | < 390 g |
| Mounting | DIN rail to IEC 60715, screws |
Part numbers
Show all part numbers (9)
B91067010, B91067010W, B91067210, B91067210W, B91067110, B91067110W, B91067901, B91067902, B91067903
How it compares with similar models
| Parameter | ISOMETER® iso685 insulation monitoring device for IT systems, AC up to 690 V and DC up to 1000 V | ISOMETER® iso685-…-B insulation monitoring device for IT systems, AC 0…690 V, DC 0…1000 V | ISOMETER® isoRW685W-D-B railway insulation monitoring device for IT systems, AC 0…690 V, DC 0…1000 V | ISOMETER® isoRW685W-D insulation monitoring device for rolling stock IT systems, AC 0…690 V, DC 0…1000 V |
|---|---|---|---|---|
| Nominal system voltage Un | AC 0…690 V; 1…460 Hz / DC 0…1000 V | — | AC 0…690 V; DC 0…1000 V | AC 0…690 V; DC 0…1000 V |
| Response value Ran1 (ALARM 1) | 1 kΩ … 10 MΩ | — | 1 kΩ…10 MΩ | 1 kΩ…10 MΩ |
| Response value Ran2 (ALARM 2) | 1 kΩ … 10 MΩ | — | 1 kΩ…10 MΩ | 1 kΩ…10 MΩ |
| Interfaces | RS-485, Ethernet (RJ45) | RS-485, Ethernet | RS-485, Ethernet, web server | RS-485, Ethernet, web server |
| Protocols | Modbus TCP, Modbus RTU, BCOM, BS bus, isoData | Modbus TCP, Modbus RTU, BCOM, isoData | Modbus RTU, Modbus TCP | Modbus RTU, Modbus TCP, BCOM, BS bus, isoData |
| Operating temperature | −25…+55 °C | −25…+55 °C | −40…+70 °C | −40…+70 °C |
Request a price and lead time
ISOMETER® iso685 insulation monitoring device for IT systems, AC up to 690 V and DC up to 1000 V. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which systems is the iso685 intended for?
AC IT systems of 0…690 V (1…460 Hz) with galvanically connected rectifiers and inverters, and DC IT systems of 0…1000 V.
How do the iso685-D and iso685-S differ?
The iso685-D has an integrated graphic display; the iso685-S has none and is operated from the FP200 front panel.
What is Option W for?
Option W is for extreme climatic and mechanical conditions, with an operating temperature of −40…+70 °C.
Similar equipment from other manufacturers