ISOMETER® isoRW685W-D insulation monitoring device for rolling stock IT systems, AC 0…690 V, DC 0…1000 V

The isoRW685W-D is tailored to the requirements of railway rolling stock. It monitors unearthed AC, DC and AC/DC circuits with response values of 1 kΩ…10 MΩ and complies with DIN EN 50155 and IEC 61557-8.

Nominal system voltage Un
AC 0…690 V; DC 0…1000 V
Supply voltage Us
AC 24…240 V; 50…400 Hz / DC 24…240 V
Response value Ran1 (ALARM 1)
1 kΩ…10 MΩ
Response value Ran2 (ALARM 2)
1 kΩ…10 MΩ

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Tailored to railway rolling stock, the isoRW685W-D checks the insulation resistance of unearthed IT AC systems with galvanically connected rectifiers and inverters, and of IT DC systems. The nominal system voltage is AC 0…690 V and DC 0…1000 V, and the device is covered by DIN EN 50155, DIN EN 45545-2 and IEC 61557-8.

It supervises main circuits of AC, 3(N)AC, AC/DC and DC type without a break and signals when the resistance falls below the preset response range. Two separately adjustable ranges of 1 kΩ…10 MΩ are provided, along with automatic adaptation to the system leakage capacitance. A graphical LC display and the isoGraph history memory keep earlier readings available.

Communication runs over RS-485 and Ethernet with Modbus RTU, Modbus TCP, BCOM, BS bus and isoData, and a web server gives access to the settings. The three digital inputs (3 DI), two digital outputs (2 DO) and one analogue output (1 AO) are freely programmable.

Applications include AC, DC and AC/DC main circuits, UPS and battery systems, heaters with phase control, systems with switched-mode power supplies and IT systems with high leakage capacitance. Coupling devices AGH150W-4 and AGH204S-4 are available for connection to higher voltages.

Supply is AC 24…240 V; 50…400 Hz / DC 24…240 V with an operating temperature of −40…+70 °C. The enclosure is 108 × 93 × 110 mm and weighs under 390 g. It mounts on a DIN rail or with screws, and must be correctly connected to PE and the IT system lines. Approvals are CE, UKCA and TÜV. Terminal kits B91067901 (screw) and B91067902 (push-wire) and enclosure accessories B91067903 are ordered separately.

Technical specifications

Nominal system voltage UnAC 0…690 V; DC 0…1000 V
Supply voltage UsAC 24…240 V; 50…400 Hz / DC 24…240 V
Response value Ran1 (ALARM 1)1 kΩ…10 MΩ
Response value Ran2 (ALARM 2)1 kΩ…10 MΩ
Inputs/outputs3 DI, 2 DO, 1 AO
InterfacesRS-485, Ethernet, web server
ProtocolsModbus RTU, Modbus TCP, BCOM, BS bus, isoData
Operating temperature−40…+70 °C
Dimensions (W × H × D)108 × 93 × 110 mm
Weight< 390 g

Part numbers

Show all part numbers (4)

B91067012W, kits B91067901, B91067902, B91067903

How it compares with similar models

ParameterISOMETER® isoRW685W-D insulation monitoring device for rolling stock IT systems, AC 0…690 V, DC 0…1000 VISOMETER® isoRW685W-D-B railway insulation monitoring device for IT systems, AC 0…690 V, DC 0…1000 VISOMETER® isoHR685W high-resistance insulation monitoring device up to 10 GΩ, IT systems AC 0…1000 V, DC 0…1300 VISOMETER® iso685-…-B insulation monitoring device for IT systems, AC 0…690 V, DC 0…1000 V
Nominal system voltage UnAC 0…690 V; DC 0…1000 VAC 0…690 V; DC 0…1000 VAC 0…1000 V; 0.1…460 Hz / DC 0…1300 V—
Response value Ran1 (ALARM 1)1 kΩ…10 MΩ1 kΩ…10 MΩ1 kΩ…3 GΩ—
Response value Ran2 (ALARM 2)1 kΩ…10 MΩ1 kΩ…10 MΩ1 kΩ…3 GΩ—
Inputs/outputs3 DI, 2 DO, 1 AO3 digital inputs, 2 digital outputs, 1 analogue output3 digital inputs, 2 digital outputs, 1 analogue output3 digital inputs, 2 digital outputs, 1 analogue output
InterfacesRS-485, Ethernet, web serverRS-485, Ethernet, web serverRS-485, Ethernet, BCOM, BS busRS-485, Ethernet
ProtocolsModbus RTU, Modbus TCP, BCOM, BS bus, isoDataModbus RTU, Modbus TCPModbus RTU, Modbus TCPModbus TCP, Modbus RTU, BCOM, isoData

Request a price and lead time

ISOMETER® isoRW685W-D insulation monitoring device for rolling stock IT systems, AC 0…690 V, DC 0…1000 V. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What is the isoRW685W-D intended for?

Railway rolling stock: monitoring IT AC systems with rectifiers and inverters and IT DC systems, in line with DIN EN 50155.

Which communication protocols does it support?

Modbus RTU, Modbus TCP, BCOM, BS bus and isoData over RS-485 and Ethernet.

What system and supply voltages does it cover?

Systems up to AC 0…690 V or DC 0…1000 V, with a supply of AC 24…240 V; 50…400 Hz / DC 24…240 V.