IOM441-S and IOM441W-S Relay Module with 12 N/O Contacts, DC 24 V

The IOM441-S adds twelve potential-free relay outputs to devices such as the EDS44x. It is supplied with DC 24 V over the BB bus, its contacts are rated AC 250 V / DC 30 V at 5 A, and the IOM441W-S withstands higher shock and vibration.

Supply voltage Us
DC 24 V (tolerance 5 %)
Power consumption
< 1.7 W
Number of outputs
12 N/O contacts (N/O or N/C selectable)
Rated operational voltage of contacts
AC 250 V / DC 30 V

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The IOM441-S relay module extends the manufacturer's devices, for example the EDS44x. Alarm messages of the basic device can be converted into switching commands for the 12 relay outputs, which have N/O contacts. The two devices communicate over the manufacturer's backbone bus (BB bus), mounted on the rear of the devices. The BB bus also supplies the IOM441-S, and a software update can be carried out through it.

Parameters and switching states are stored in the module. An alarm contact (N/O) is available for each measuring channel of the basic device, for example to trip a circuit breaker when the response value in that outgoing circuit is exceeded. The application is extending the measuring channels during insulation fault location by potential-free contacts. Each contact can be set to N/O or N/C. Some basic devices accept only one IOM441-S, so the data sheet of the basic device must be checked, and the module is connected only to the right of the basic device.

Supply voltage Us is DC 24 V with a tolerance of 5 %, and power consumption is below 1.7 W. Contacts are rated AC 250 V / DC 30 V at 5 A, with a minimum contact rating of 1 mA at DC 5 V or more. Protective separation (reinforced insulation) between the BB bus and the contacts is specified for a rated voltage of 250 V, overvoltage category III, pollution degree 2 and rated impulse voltage of 6 kV.

The W version has increased shock and vibration resistance, with the electronics covered in a special varnish, and operates at −40…+70 °C; the standard version operates at −25…+55 °C. The plug-in push-wire terminals take 0.2…2.5 mm² conductors, AWG 24…12, with a stripping length of 10 mm. Mounting is on a DIN rail to IEC 60715 or by screws (2 x M4 with mounting clip). The polycarbonate enclosure is UL 94V-0, protection is IP40 for internal components and IP20 for terminals, and weight is approx. 180 g. The model is discontinued.

Technical specifications

Supply voltage UsDC 24 V (tolerance 5 %)
Power consumption< 1.7 W
Number of outputs12 N/O contacts (N/O or N/C selectable)
Rated operational voltage of contactsAC 250 V / DC 30 V
Rated operational current5 A
Minimum contact rating1 mA at ≥ DC 5 V
Rated impulse voltage6 kV
Overvoltage category / pollution degreeIII / 2
Connectionpluggable push-wire terminals, 0.2…2.5 mm², AWG 24…12
Operating temperature−25…+55 °C (IOM441W-S −40…+70 °C)
Transport temperature−40…+85 °C
Storage temperature−25…+70 °C
Degree of protectionIP40 (internal components), IP20 (terminals)
Enclosurepolycarbonate, UL 94V-0
MountingDIN rail IEC 60715 or screws 2 x M4
Dimensions (W x H x D)72 x 93 x 63 mm
Weightapprox. 180 g

Part numbers

Show all part numbers (2)

B95012057 (IOM441-S), B95012057W (IOM441W-S)

How it compares with similar models

ParameterIOM441-S and IOM441W-S Relay Module with 12 N/O Contacts, DC 24 VISOMETER® iso415R insulation monitoring device for AC/DC IT systems up to 400 VLINETRAXX® RCMB330 AC/DC sensitive residual current monitoring module, 10…500 mA, RS-485RCMB104 AC/DC residual current monitoring module for EV charging systems
Operating temperature−25…+55 °C (IOM441W-S −40…+70 °C)−25…+55 °C—-30…80 °C
Storage temperature−25…+70 °C−40…+70 °C—-40…85 °C
Degree of protectionIP40 (internal components), IP20 (terminals)IP20—IP00

Request a price and lead time

IOM441-S and IOM441W-S Relay Module with 12 N/O Contacts, DC 24 V. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How does the IOM441W-S differ from the IOM441-S?

The IOM441W-S has increased shock and vibration resistance and varnished electronics, and operates at −40…+70 °C against −25…+55 °C.

How is the module supplied and linked to the basic device?

Through the BB bus on the rear of the devices, which carries the DC 24 V supply and the communication; the module is connected only to the right of the basic device.

What load can the contacts carry?

Rated operational voltage is AC 250 V / DC 30 V at a rated current of 5 A, with a minimum contact rating of 1 mA at DC 5 V or more.