AGH204S-4 Coupling Device for ISOMETER® in 3AC IT Systems up to 1650 V

Used with an ISOMETER®, the AGH204S-4 monitors the insulation of 3AC IT systems: terminal AK160 extends the range to 3(N)AC 0…1650 V and AK80 to 0…1300 V. DIN rail or screw mounting, halogen-free enclosure.

Nominal system voltage Un (AK80)
0…1300 V
Nominal system voltage Un (AK160)
3(N)AC 0…1650 V
Un for UL applications
AC 0…1500 V
Frequency range of Un
50…400 Hz

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The AGH204S-4 is used together with an ISOMETER® to monitor the insulation of 3AC IT systems (unearthed systems). It extends the nominal voltage range of the ISOMETER series shown in the wiring diagram, to 3(N)AC 0…1650 V at terminal AK160 and to 3(N)AC 0…1300 V at terminal AK80. The 0…1300 V range applies without converters, while 0…1650 V is shown for a system with converters. The iso685 series is named as compatible.

The maximum permissible DC link voltage is 1840 V, and the AGH204S-4 is not designed for operation or coupling in DC systems. In systems above 690 V nominal voltage with overvoltage category III, a fuse must be provided for the connection to the monitored system, and 2 A is recommended. The connecting lead from the ISOMETER to the AGH must not exceed 0.5 m.

Internal DC resistance Ri is 80 kΩ when coupled to AK80 and 160 kΩ when coupled to AK160. Rated insulation voltage is AC 1500 V and rated impulse voltage is 10.4 kV. The screw terminals accept 0.2…4 mm² rigid or 0.2…2.5 mm² flexible conductors, AWG 24…12, tightened to 0.5 Nm. The frequency range of Un is 50…400 Hz, and AC 0…1500 V applies to UL applications.

The X112 enclosure is halogen-free with flammability class UL 94 V-0. Protection is IP30, with IP10 for built-in components. Mounting is on a DIN rail to IEC 60715 or by screws, in any position, for continuous operation. Dimensions are 111 x 109 x 61 mm and weight is up to 1350 g. Ambient temperature is −10…+55 °C in operation and −40…+70 °C in storage, climatic class 3K23 to IEC 60721. It was developed to DIN EN 61800-5-1 (VDE 0160-105-1), and the model is discontinued.

Technical specifications

Nominal system voltage Un (AK80)0…1300 V
Nominal system voltage Un (AK160)3(N)AC 0…1650 V
Un for UL applicationsAC 0…1500 V
Frequency range of Un50…400 Hz
Rated insulation voltageAC 1500 V
Rated impulse voltage10.4 kV
Overvoltage categoryIII
Internal DC resistance Ri (coupling to AK80 / AK160)80 kΩ / 160 kΩ
Maximum DC link voltage1840 V
Terminalsscrew type, 0.2…4 mm² / 0.2…2.5 mm², AWG 24…12, 0.5 Nm
Length of connecting lead ISOMETER® to AGH≤ 0.5 m
Degree of protectionIP30, built-in components IP10
EnclosureX112, halogen-free, UL 94 V-0
MountingDIN rail IEC 60715 or screws, any position
Ambient temperature, operation−10…+55 °C
Storage temperature−40…+70 °C
Dimensions111 x 109 x 61 mm
Weight≤ 1350 g

Part numbers

Show all part numbers (1)

B914013

How it compares with similar models

ParameterAGH204S-4 Coupling Device for ISOMETER® in 3AC IT Systems up to 1650 VAGH520S Coupling Device for ISOMETER® in 3(N)AC Systems up to 7.2 kVAGH150W and AGH150W-4 Coupling Devices for ISOMETER® in AC 1150 V and DC up to 1760 V SystemsISOMETER® isoPV425 with AGH420 insulation monitoring device for AC/DC IT systems up to 690 V / 1000 V
Frequency range of Un50…400 Hz50…400 Hz—DC, 1…460 Hz
Rated insulation voltageAC 1500 VAC 6.3 kVAC 1000 V (AGH150W); AC 1600 V (AGH150W-4)1000 V
Rated impulse voltage10.4 kV—≥ 8 kV (AGH150W); ≥ 11 kV (AGH150W-4)8 kV
Overvoltage categoryIIIIIICAT IIIIII
Degree of protectionIP30, built-in components IP10IP64, built-in components IP20IP30, built-in components IP10IP30 (built-in components), IP20 (terminals)
Ambient temperature, operation−10…+55 °C−10…+55 °C (UL −10…+45 °C)−40…+70 °C (UL −10…+55 °C)—

Request a price and lead time

AGH204S-4 Coupling Device for ISOMETER® in 3AC IT Systems up to 1650 V. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Can the AGH204S-4 be used in DC systems?

No. It is not designed for operation or coupling in DC systems, and the maximum DC link voltage is 1840 V.

How do terminals AK80 and AK160 differ?

AK80 extends the range to 3(N)AC 0…1300 V with Ri of 80 kΩ, and AK160 to 3(N)AC 0…1650 V with Ri of 160 kΩ.

Is a fuse required?

In systems above 690 V with overvoltage category III, a fuse must be provided for the connection to the monitored system, and 2 A is recommended.