CD25000 coupling device for NGR monitoring in HRG systems up to AC 25 kV and DC 14.5 kV

The CD25000 extends the range of an NGR monitor in HRG systems up to AC 25 kV and/or DC 14.5 kV. Rated voltage is 14500 V, protection is IP54, and a ground fault may last up to 10 s followed by a 120 min cool-down.

System voltage
до AC 25 kV / DC 14.5 kV
Rated voltage
14500 V
Rated insulation voltage
14500 V
Current
145 mA

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The CD25000 is a coupling device that widens the range of an NGR monitor in high resistance grounding (HRG) systems with a system voltage up to AC 25 kV and/or DC 14.5 kV.

Rated voltage is 14500 V and rated insulation voltage 14500 V. Current is 145 mA, resistance 100 kΩ and temperature coefficient 20 ppm/K. The voltage range is DC, 50/60 Hz, 10…3200 Hz, with overvoltage category III and pollution degree 2.

In case of a ground fault the duty time is a maximum of 10 s, followed by a cool-down period of 120 min.

The enclosure has protection IP54 and flammability class UL 94 V-0. It measures 650 x 600 x 270.6 mm and weighs less than 11 kg. It can be mounted in any position at altitudes up to 5000 m AMSL, with ambient temperature -40…+70 °C (-40…+60 °C for UL) and humidity up to 98 %.

Connection N is made through an HV line (1.8 m) with an open end cable, and PE through a cable lug supplied by the customer (tightening torque for cable lug M5 is 2.2 Nm). Conductors are 0.2…4 mm² rigid, 0.2…2.5 mm² flexible or AWG 24-12, with 7 mm stripping length, 0.5…0.6 Nm tightening torque and 2.5 Nm for cover screws. The device follows DIN EN 50178:1997, DIN EN 60529 and the IEC 60721-3 series. Part number: B98039055.

Technical specifications

System voltageдо AC 25 kV / DC 14.5 kV
Rated voltage14500 V
Rated insulation voltage14500 V
Current145 mA
Resistance100 kΩ
Temperature coefficient20 ppm/K
Voltage rangeDC, 50/60 Hz, 10…3200 Hz
Overvoltage categoryIII
Pollution degree2
Operating modein case of a ground fault maximum 10 s; cool-down 120 min
Degree of protectionIP54
Flammability classUL 94 V-0
Dimensions650 x 600 x 270.6 mm
Weight< 11 kg
Ambient temperature-40…+70 °C
Ambient temperature for UL-40…+60 °C
Operating altitudeup to 5000 m AMSL
Connection NHV line (1.8 m) with open end cable

Part numbers

Show all part numbers (1)

B98039055

How it compares with similar models

ParameterCD25000 coupling device for NGR monitoring in HRG systems up to AC 25 kV and DC 14.5 kVCD14400 coupling device for NGR monitoring in HRG systems up to 14400 VCD5000 coupling device for NGR monitoring in HRG systems up to AC 4300 V and DC 2500 VCD1000-2 coupling device for NGR monitors in HRG systems up to 1000 V
Rated voltage14500 V8400 V2500 V600 V
Rated insulation voltage14500 V8400 V3 kV—
Resistance100 kΩ100 kΩ20 kΩ20 kΩ
Flammability classUL 94 V-0—UL 94V-0UL 94V-0
Weight< 11 kg< 4.4 kg< 3800 g< 700 g

Request a price and lead time

CD25000 coupling device for NGR monitoring in HRG systems up to AC 25 kV and DC 14.5 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which systems is the CD25000 intended for?

HRG systems with a system voltage up to AC 25 kV and/or DC 14.5 kV that use an NGR monitor.

How long may a ground fault last?

A maximum of 10 s, followed by a cool-down period of 120 min.

How are N and PE connected?

N through an HV line (1.8 m) with an open end cable, and PE through a cable lug supplied by the customer.