CD5000 coupling device for NGR monitoring in HRG systems up to AC 4300 V and DC 2500 V
The CD5000 links an NGR monitor to high resistance grounding (HRG) systems with a system voltage up to AC 4300 V and/or DC 2500 V. Rated voltage is 2500 V, resistance 20 kΩ, and operation is continuous.
- System voltage
- до AC 4300 V / DC 2500 V
- Rated voltage
- 2500 V
- Rated current
- 125 mA
- Resistance
- 20 kΩ
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Designed for use with NGR monitors in high resistance grounding (HRG) systems, the CD5000 coupling device suits system voltages up to AC 4300 V and/or DC 2500 V. It is rated for continuous operation.
Rated voltage is 2500 V, rated current 125 mA, resistance 20 kΩ and rated insulation voltage 3 kV. The voltage range is DC, 50/60 Hz, 10…3200 Hz, and overload capacity is 1.15 x Un for less than 5 minutes. Temperature coefficient is ± 1 % / 20 ppm/K, overvoltage category III and pollution degree 2.
Terminals G1 and G take a cable lug with a conductor of at least 1.5 mm². PE takes a cable lug M6 or M10 with at least 2.5 mm². Tightening torque is 0.5…0.6 Nm and conductor sizes are AWG 24-12.
The device mounts in any position on a grounded metal plate of at least 600 x 300 mm. Operating altitude is up to 5000 m AMSL, ambient temperature -40…+70 °C (-40…+60 °C for UL) and humidity up to 98 %. Internal components are IP0, flammability class is UL 94V-0 and weight is under 3800 g.
It follows DIN EN 50178:1997 and DIN EN 60529, with environmental conditions per the IEC 60721-3 series. Part number: B98039011.
Technical specifications
| System voltage | до AC 4300 V / DC 2500 V |
|---|---|
| Rated voltage | 2500 V |
| Rated current | 125 mA |
| Resistance | 20 kΩ |
| Rated insulation voltage | 3 kV |
| Voltage range | DC, 50/60 Hz, 10…3200 Hz |
| Overload capacity | 1.15 x Un for < 5 minutes |
| Overvoltage category | III |
| Pollution degree | 2 |
| Ambient temperature | -40…+70 °C |
| Ambient temperature for UL | -40…+60 °C |
| Humidity | ≤ 98 % |
| Tightening torque | 0.5…0.6 Nm |
| Conductor sizes | AWG 24-12 |
| Operating altitude | up to 5000 m AMSL |
| Flammability class | UL 94V-0 |
| Weight | < 3800 g |
Part numbers
Show all part numbers (1)
B98039011
How it compares with similar models
| Parameter | CD5000 coupling device for NGR monitoring in HRG systems up to AC 4300 V and DC 2500 V | CD14400 coupling device for NGR monitoring in HRG systems up to 14400 V | CD25000 coupling device for NGR monitoring in HRG systems up to AC 25 kV and DC 14.5 kV | CD1000-2 coupling device for NGR monitors in HRG systems up to 1000 V |
|---|---|---|---|---|
| Rated voltage | 2500 V | 8400 V | 14500 V | 600 V |
| Resistance | 20 kΩ | 100 kΩ | 100 kΩ | 20 kΩ |
| Rated insulation voltage | 3 kV | 8400 V | 14500 V | — |
| Flammability class | UL 94V-0 | — | UL 94 V-0 | UL 94V-0 |
| Weight | < 3800 g | < 4.4 kg | < 11 kg | < 700 g |
Request a price and lead time
CD5000 coupling device for NGR monitoring in HRG systems up to AC 4300 V and DC 2500 V. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which systems is the CD5000 intended for?
HRG systems with a system voltage up to AC 4300 V and/or DC 2500 V that use an NGR monitor.
How is the CD5000 mounted?
In any position on a grounded metal plate of at least 600 x 300 mm.
What is its overload capacity?
1.15 x Un for less than 5 minutes, at a rated voltage of 2500 V.