HighPROTEC MCDLV4 — longitudinal differential protection for cables and lines up to 40 km

HighPROTEC MCDLV4 is a longitudinal differential protection system for cables and overhead lines up to 40 km long, built from two terminals at the line ends. The set combines line differential protection, backup directional feeder protection, in-zone transformer protection and grid decoupling protection.

Protected line length
up to 40 km
Replaces
up to 6 devices (2 line differential protections, 2 backup directional protections, in-zone transformer differential protection, decoupling protection)
Transformer in the zone
full differential protection
Signal transmission
up to 16 binary signals and 4 trip commands between the terminals

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The MCDLV4 from the HighPROTEC line protects cables and overhead lines up to 40 km long. The system consists of two terminals at the line ends and replaces up to six separate devices. These are two cable or line differential protection devices, two backup directional feeder protection devices, one in-zone transformer differential protection and one grid decoupling protection. The functions are adapted to VDE-AR-N 4110:2023-09.

If a transformer is included in the line or cable connection, the in-zone transformer differential function protects it in full. The communication channel between the two terminals carries up to 16 binary signals and 4 trip commands, so copper pilot cables between substations are no longer needed. Settings, monitoring and fault analysis of the remote end can be handled without sending personnel to site.

The backup directional feeder protection has six phase overcurrent stages, directional and non-directional, with 51C/51V functions, and four earth-fault stages, non-directional or directional with multi-polarisation. There is also wattmetric earth-fault protection, two load unbalance stages, six voltage protection stages and six voltage unbalance monitoring stages. The flexible fourth voltage input works as VE> or for synchronism check. Six frequency and six power stages are complemented by two power factor stages and a limit on the maximum exported power. The decoupling protection package includes non-selective unloading by active power direction, FRT (LVRT) profiles coordinated with auto-reclosing, Q-U protection, automatic reconnection, frequency protection (f<, f>, df/dt, vector jump), breaker trip transfer and synchronism check.

Each terminal controls up to six switching devices and keeps a breaker wear record. Communication with the SCADA system runs over Modbus, Profibus, DNP3.0, IEC 61850, IEC 60870-5-103 and IEC 60870-5-104 with individual data point assignment, time is synchronised by SNTP and IRIG-B, and cybersecurity functions are provided. The hardware is dual-core, and non-volatile recorders store waveforms of 120 s, 20 faults, 300 events and a trend of 4000 records. Smart view and waveform analysis are supplied at no extra charge under the all-inclusive concept. The system is installed on cable lines of urban and industrial 6–35 kV networks, on renewable power export lines and on interconnections between substations.

Technical specifications

Protected line lengthup to 40 km
Replacesup to 6 devices (2 line differential protections, 2 backup directional protections, in-zone transformer differential protection, decoupling protection)
Transformer in the zonefull differential protection
Signal transmissionup to 16 binary signals and 4 trip commands between the terminals
Backup protections6 overcurrent stages (directional), 4 earth-fault stages, wattmetric, voltage, frequency, power
Decoupling packageLVRT, Q-U, automatic reconnection, synchronism check
Switching devicesup to 6

Request a price and lead time

HighPROTEC MCDLV4 — longitudinal differential protection for cables and lines up to 40 km. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8537 10 98 00
HS, 6 digits8537 10
CN (EU)8537 10 98
HTSUS (USA)8537 10 91 70
China customs tariff8537 10 90 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What line length does the MCDLV4 protect?

Cables and overhead lines up to 40 km long. The set consists of two terminals at the line ends.

Which signals are transmitted between the MCDLV4 terminals?

Up to 16 binary signals and 4 trip commands, so copper pilot cables between substations are not needed.

Does the MCDLV4 protect a transformer included in the line?

Yes, the in-zone transformer differential protection function fully protects a transformer included in a line or cable connection.