БШД-01 shunting and deshunting block for protection schemes, minimum shunting current 0.3 A

The БШД-01 shunts and deshunts a controlled current circuit without contacts, using a triac, in protection and automation schemes powered from the secondary circuits of phase A and C current transformers. Minimum shunting current is 0.3 A and control is 24 V, 15 mA.

Block supply
from phase A and C current circuits through built-in current transformers
Working current ranges of transformer windings
(1-2), (2-4), (4-8) A
Rated currents
1.5; 3; 5 A
Minimum shunting current
0.3 A

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The БШД-01 is meant for protection and automation schemes that take their power from the secondary circuits of the phase A and C current transformers. A triac shunts and deshunts the controlled current circuit without contacts, provided its impedance is no more than 4 Ohm at 4 A and no more than 1.5 Ohm at 50 A.

The controlled circuit can be the trip coils of drives such as ПРБА, ПП-61, ПП-67 and ПГ-10, or similar ones. The block can stand in for two relays of the РП-321, РП-341 or РП-361 types and their equivalents.

Control comes from a discrete output (dry contact) of an external protection device, at a nominal 24 V and 15 mA. Built-in current transformers in phases A and C supply the block. Their working current ranges are (1-2), (2-4) and (4-8) A, rated currents are 1.5; 3 and 5 A, and the minimum shunting current is 0.3 A.

LEDs show power and deshunting of phases A and C. The indication and control circuits draw up to 7 VA from the current circuit.

Enclosure protection is IP40 and terminal protection IP10 to ГОСТ 14254-96. Insulation resistance is at least 50 MOhm cold, 10 MOhm at 55 °C and 1 MOhm at 98 % humidity at 35 °C. The insulation withstands 2 kV, 50 Hz for 60 s and a 5 kV impulse (1.2 µs front, 50 µs duration, 5 s repetition). Dimensions are 140 х 72 х 161 mm and mass is up to 0.9 kg. A БШД-01-200 version exists.

Technical specifications

Block supplyfrom phase A and C current circuits through built-in current transformers
Working current ranges of transformer windings(1-2), (2-4), (4-8) A
Rated currents1.5; 3; 5 A
Minimum shunting current0.3 A
Discrete input control voltage24 V
Discrete input control current15 mA
Indication and control power from current circuitmax 7 VA
Enclosure / terminal protectionIP40 / IP10
Insulation resistance (cold)min 50 MOhm
Insulation resistance (55 °C)min 10 MOhm
Insulation resistance (98 % at 35 °C)min 1 MOhm
AC test voltage2 kV, 50 Hz, 60 s
Impulse test voltage5 kV, 1.2 µs, 50 µs, 5 s
Dimensions140 х 72 х 161 mm
Massmax 0.9 kg

Part numbers

Show all part numbers (2)

БШД-01, БШД-01-200

How it compares with similar models

ParameterБШД-01 shunting and deshunting block for protection schemes, minimum shunting current 0.3 ABU-220-01 control unit for ISM15_LD switching modules, 230 V supplyВР-220-01 power supply unit for BU/TEL-220-XX (BU-220-01) control blocks, 230 V outputAN450 power supply unit, AC 20 V, up to 9 VA, for MK2430
Dimensions140 х 72 х 161 mmmax 192×120×68 mm180×132×61 mm—
Massmax 0.9 kgmax 2 kgmax 2 kg—

Request a price and lead time

БШД-01 shunting and deshunting block for protection schemes, minimum shunting current 0.3 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which circuits can the БШД-01 shunt?

A controlled current circuit with an impedance of no more than 4 Ohm at 4 A and 1.5 Ohm at 50 A, such as trip coils of ПРБА, ПП-61, ПП-67 and ПГ-10 drives.

How is the block controlled and powered?

By a dry contact output of an external protection device (24 V, 15 mA). Power comes from the phase A and C current circuits through built-in current transformers.

Which relays can it replace?

Two relays of the РП-321, РП-341 or РП-361 types and similar ones.