AT series luminous display panels for room occupancy indication, LED, IP40
The AT series panels have transparent luminous lenses that show room occupancy or usage, for example while a laser or X-ray unit is running. LED lighting, IP40. Enclosures for flush, surface and ceiling mounting.
- Type
- Transparent luminous display panels
- Light source
- LED
- Degree of protection
- IP40
- Max. wire cross-section
- 2.5 mm²
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
AT series panels are signs fitted above doors to show that a room is occupied, in use, or not to be entered. They are used in hospitals and doctors' offices, including tomography, laser and X-ray departments, and in chemistry, biology and virology laboratories. Other places are technical testing laboratories, darkrooms, radio and recording studios, theatres, cinemas, conference and seminar rooms, waiting rooms and controlled areas.
The lit surface uses long-lived LEDs and is evenly illuminated. The coloured lenses have no screws on the front; they slide into the box from the side and are held by two screws on top. Individual labelling and coloured lenses are made on request. The degree of protection is IP40 and the maximum connecting wire cross-section is 2.5 mm².
Three enclosure types are offered. The flush-mounting wall box is 1 mm galvanised steel with a 3 mm anodised aluminium bezel frame that extends the box by about 7 mm to cover the gap in the wall. The aluminium surface enclosure comes in two versions: screwed to the wall through pre-drilled holes in the back, or partially recessed on a standard circular 68 mm one-gang junction box for cavity walls. The aluminium ceiling enclosure mounts on the same 68 mm box and has two luminous lenses, so it can be read from both sides in a hallway.
The panels follow IEC/EN 61439-1 and IEC/DIN EN 60598-1. They are not warning or safety lights under DIN 4844 or DIN EN ISO 7010, although the pictograms used comply with those standards.
Technical specifications
| Type | Transparent luminous display panels |
|---|---|
| Light source | LED |
| Degree of protection | IP40 |
| Max. wire cross-section | 2.5 mm² |
| Mounting | Flush (aluminium bezel frame), surface and partially recessed surface, ceiling (aluminium enclosure) |
| Flush-mounting wall box | Galvanised steel, 1 mm |
| Flush bezel frame | Anodised aluminium, 3 mm |
| Standards | IEC/EN 61439-1, IEC/DIN EN 60598-1 |
How it compares with similar models
| Parameter | AT series luminous display panels for room occupancy indication, LED, IP40 | ATICS®-2-…-ISO automatic transfer switching device with IT system monitoring, 63 and 80 A | DS0107 Three-Phase Isolating Transformers with Reinforced Insulation for Three-Phase Loads | WN series measuring current transformers for AC and DC residual current |
|---|---|---|---|---|
| Type | Transparent luminous display panels | — | three-phase isolating transformer | Вимірювальний трансформатор струму |
| Degree of protection | IP40 | IP40 | IP00 (open design), IP23 (with enclosure) | — |
| Standards | IEC/EN 61439-1, IEC/DIN EN 60598-1 | — | IEC 61558-1, DIN EN 61558-1 (VDE 0570-1), IEC 61558-2-15, DIN EN 61558-2-15 (VDE 0570-2-15), IEC 60364-7-710, DIN VDE 0100-710 | IEC 62752, IEC 62955 |
Request a price and lead time
AT series luminous display panels for room occupancy indication, LED, IP40. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Where are AT series panels installed?
Above doors in hospitals, laboratories, studios, cinemas, conference rooms, waiting rooms and controlled areas.
Which mounting options are there?
Flush with an aluminium bezel frame, surface (on the wall or partially recessed in a 68 mm box) and an aluminium ceiling enclosure.
Are the panels warning lights under DIN 4844?
No. They are not warning or safety lights under DIN 4844 or DIN EN ISO 7010, although the pictograms used comply with those standards.