АЛ-3-В (AL-3-V) is a two-phase microprocessor overcurrent relay with an independent time delay. It needs no auxiliary supply, covers 1-99 A with a delay of 0.1-99 s, and has one output relay with two contacts.

Operating current range
1...99 A
Rated current, setting range
2.5 A (1-5 A); 6.3 A (4-14 A); 16 A (12-99 A)
Time delay range
0.1...99 s
Continuous thermal withstand
2 Ін

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The АЛ-3-В series is used in relay protection schemes and emergency automation to detect a rise of current in monitored circuits. When the monitored value reaches a preset level the relay switches the electrical circuits. It is a microprocessor counterpart of electromechanical and microelectronic current relays, operates on two phases and applies an independent delay.

The operating current range is 1 to 99 A and the delay is 0.1 to 99 s. By rated current the relay comes in 2.5 A, 6.3 A and 16 A versions, with setting ranges of 1-5 A, 4-14 A and 12-99 A respectively. Continuous thermal withstand is 2 Ін.

There is a single output relay with one normally open and one normally closed contact. Operate time is not more than 60 ms at 1.2 times the setting and not more than 50 ms at 3.0 times.

Ambient temperature is minus 40 to plus 55 °C, altitude up to 2000 m, and relative humidity up to 98% at 25 °C. Mechanical group is М7 and the climatic version is У3 (category 3), with operating conditions per ГОСТ 15150-69 and ГОСТ 17516.1.

Mount the relay on a DIN rail or as a protruding unit. Current and time settings are made on the relay itself.

Technical specifications

Operating current range1...99 A
Rated current, setting range2.5 A (1-5 A); 6.3 A (4-14 A); 16 A (12-99 A)
Time delay range0.1...99 s
Continuous thermal withstand2 Ін
Output relays1
Output relay contacts1 normally open and 1 normally closed
Operate time at 1.2 times settingnot more than 60 ms
Operate time at 3.0 times settingnot more than 50 ms
Ambient temperaturefrom minus 40 to plus 55 °C
Altitudeup to 2000 m
Relative humidityup to 98% at 25 °C
Mechanical groupМ7
Climatic versionУ3 (category 3)
StandardsГОСТ 15150-69, ГОСТ 17516.1

Part numbers

Show all part numbers (1)

АЛ-3-В

European equivalents

IPR-A / IPR-A2 / IPR-D / IPR96D overcurrent and earth fault protection relays for MV feeders

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

AL-3-V two-phase overcurrent relay (АЛ-3-В), self-powered, 1-99 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Does the АЛ-3-В need an auxiliary supply?

No, the relay operates without an auxiliary supply.

What current and time ranges does it cover?

Operating current 1...99 A and time delay 0.1...99 s.

What contacts does the output relay have?

One normally open and one normally closed contact.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides