Aperval — pilot-operated gas pressure regulator for medium-pressure networks, inlet up to 25 bar

Aperval pilot-operated gas pressure regulator for inlet pressure up to 25 bar and outlet pressure from 0.005 to 9.5 bar. Sizes from 1″ to 4″, flanges of class 150 and PN 16. Works in pressure reduction stations and units of distribution networks and in cabinet reduction stations of large consumers.

Type
pilot-operated regulator; Fail Open per EN 334
Design pressure
up to 25 bar
Inlet pressure
0.5–25 bar
Outlet pressure
0.005–9.5 bar

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Aperval is a pilot-operated gas pressure regulator intended primarily for medium and low pressure natural gas distribution networks. It works with pre-filtered non-corrosive gases and under EN 334 is classified as normally open (Fail Open). The pilot scheme holds the outlet pressure accurately at high flow rates and noticeable fluctuations of the inlet pressure, which matters at network stations supplying city districts and industrial zones.

Design pressure is up to 25 bar, inlet pressure is from 0.5 to 25 bar, and outlet pressure is from 0.005 to 9.5 bar. The regulator can reduce medium pressure to low pressure (from 5 mbar) for domestic and commercial networks or maintain medium pressure for industrial consumers. The minimum pressure differential is 0.45 bar.

Nominal sizes are 1″, 2″, 2½″, 3″ and 4″, with flanged connections of class 150 RF or RTJ per ASME B16.5 and PN 16. Accuracy class AC is up to 5 (up to 1 % absolute), and lock-up pressure class SG is up to 10. Design temperature is from −20 to +60 °C, higher or lower temperatures on request.

The configuration may include a safety shut-off valve, a monitor and a silencer; the variants can be combined, and see the technical manual for permissible combinations. A separate Aperval H model is available for 100 % hydrogen, and a hydrogen compatibility declaration is provided for the standard version. The related Aperval 101 model is also part of the range.

The regulator is used at pressure reduction stations and units of medium-pressure networks, in cabinet reduction stations of large consumers, in boiler houses and industrial plants, and in the second stage of reduction after GDS. Inlet pressure up to 25 bar places it in the medium pressure equipment category, although at the outlet it can also produce low pressure.

Technical specifications

Typepilot-operated regulator; Fail Open per EN 334
Design pressureup to 25 bar
Inlet pressure0.5–25 bar
Outlet pressure0.005–9.5 bar
Min. differential0.45 bar
Nominal sizes1″, 2″, 2½″, 3″, 4″
Connectionsclass 150 RF/RTJ per ASME B16.5; PN 16
Accuracy class ACup to 5 (up to 1 % abs.)
Lock-up pressure class SGup to 10
Temperaturefrom −20 to +60 °C (others on request)
OptionsSSV, monitor, silencer; Aperval H version for 100 % H2; related model Aperval 101

Request a price and lead time

Aperval — pilot-operated gas pressure regulator for medium-pressure networks, inlet up to 25 bar. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What are the inlet and outlet pressure ranges of Aperval?

Inlet pressure is from 0.5 to 25 bar, and outlet pressure is from 0.005 to 9.5 bar. The minimum pressure differential is 0.45 bar.

Which nominal sizes and connections are available?

Sizes are 1″, 2″, 2½″, 3″ and 4″. Connections are flanged, class 150 RF or RTJ per ASME B16.5 and PN 16.

Is there a version for hydrogen?

A separate Aperval H model is available for 100 % hydrogen. A hydrogen compatibility declaration is provided for the standard version.