International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

FioSonic / FioSonic Mini — multipath ultrasonic gas meters for custody transfer, DN 80–750

FioSonic and FioSonic Mini are industrial multipath chordal ultrasonic gas meters for custody transfer. FioSonic covers DN 80–750 and a flow of 9 to 43 698 m³/h at a pressure up to 102 bar, and Mini is intended for gas distribution networks in sizes DN 80 and DN 100.

Type
multipath chordal ultrasonic gas meter, no moving parts
FioSonic: flow
9–43 698 m³/h
FioSonic: pressure
up to 102 bar
FioSonic: sizes
DN 80 (3″) – DN 750 (30″)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Both meters use multipath chordal ultrasonic technology. Pairs of transducers measure the transit time of the ultrasonic signal with and against the flow along several chords of the cross-section, and the gas velocity and volumetric flow are calculated from the time difference. Several paths provide redundancy, high accuracy and real-time diagnostics, and the absence of moving parts reduces wear and maintenance needs. The meters support unidirectional and bidirectional measurement, which is required for reverse gas flow points and underground gas storage.

FioSonic is the main model for high flows. The flow is from 9 to 43 698 m³/h, the pressure up to 102 bar, and the sizes from DN 80 (3″) to DN 750 (30″). Connections are PN 16 flanges per EN 1092-1 and ANSI 150/300/600 per ASME B16.5 with RF or RTJ facing. The accuracy class is 0.5 per OIML R137-1 or class 1 per MID 2014/32/EU and OIML R137-1, the measuring range is up to 1:100, and the repeatability is better than 0.1 %. The ambient and gas temperature is from −25 to +55 °C. The meter is used at gas distribution stations, compressor stations, underground storage, and liquefaction, regasification and gas treatment plants.

The body is made of ASTM A350 LF2 steel, the electronics enclosure of epoxy-coated aluminum alloy or 316 stainless steel, and the transducers of titanium. BCW (burst continuous wave) technology and low-voltage sensors are used. FioSonic Mini is intended for custody transfer in gas distribution networks. The sizes are DN 80 and DN 100, the pressure up to 20 bar (abs.), the flanges class 150 or PN 16, the body 6082 aluminum, class 1 with air calibration, a range of up to 1:67, and a gas temperature from −30 to +75 °C. The kit may include a TI-TWIN flow conditioner made of 316 steel.

Both meters have IP66/NEMA 4X protection, the intrinsically safe ATEX Ex II 1 G Ex ia IIC T4 Ga version, and IECEx and CQPSUS (Class 1 Div.1) certificates. They comply with AGA Report No. 9 and ISO 17089-1, are certified to PED, MID, ATEX and OIML R137, and are suitable for hydrogen blends up to 30 %.

Technical specifications

Typemultipath chordal ultrasonic gas meter, no moving parts
FioSonic: flow9–43 698 m³/h
FioSonic: pressureup to 102 bar
FioSonic: sizesDN 80 (3″) – DN 750 (30″)
FioSonic: connectionsPN 16 RF/RTJ (EN 1092-1); ANSI 150/300/600 RF/RTJ (ASME B16.5)
FioSonic: accuracy classclass 0.5 OIML R137-1; class 1 MID / OIML
FioSonic MiniDN 80, DN 100; up to 20 bar(a); class 150 or PN 16; 6082 aluminum body; range up to 1:67
Measuring rangeFioSonic up to 1:100
Repeatabilitybetter than 0.1 %
TemperatureFioSonic: ambient and gas −25…+55 °C; Mini: gas −30…+75 °C
Explosion protectionATEX Ex II 1 G Ex ia IIC T4 Ga; IECEx; CQPSUS Class 1 Div.1
ProtectionIP66 / NEMA 4X
MaterialsFioSonic: body ASTM A350 LF2; transducers titanium ASTM B348 Gr.2
StandardsAGA-9, ISO 17089-1, OIML R137; MID, PED, ATEX
Hydrogenblends up to 30 % H2

Request a price and lead time

FioSonic / FioSonic Mini — multipath ultrasonic gas meters for custody transfer, DN 80–750. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What flow range and pressure does FioSonic have?

A flow from 9 to 43 698 m³/h, a pressure up to 102 bar and sizes from DN 80 (3″) to DN 750 (30″).

Which networks is FioSonic Mini intended for?

Custody transfer in gas distribution networks. Sizes DN 80 and DN 100, pressure up to 20 bar (abs.), measuring range up to 1:67.

What are the accuracy class and the explosion protection?

FioSonic has accuracy class 0.5 per OIML R137-1 or class 1 per MID. Explosion protection is ATEX Ex II 1 G Ex ia IIC T4 Ga, with IP66/NEMA 4X protection.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides