CGT-02 — gas turbine meter DN 50–400, operating pressure up to 11 MPa

CGT-02 are gas turbine meters for commercial and process metering in gas transmission and distribution systems. Sizes G65–G6500, DN 50–400, pressure from atmospheric up to 11 MPa. The CGT-02 HT version works up to +120 °C.

Sizes
G65…G6500, Qmax up to 10 000 m³/h
Nominal diameter
DN 50 … DN 400 (others on request)
Maximum operating pressure
1.0 MPa (PN10) … 11 MPa (PN110 / ANSI 600); flanges PN10–PN110, ANSI 150–600
Measuring range
1:20 (standard), 1:30 for ≥DN80, 1:50 for ≥DN100 at p ≥ 2.0 MPa

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

CGT-02 gas turbine meters are intended for measuring gas volume at pressure from atmospheric up to 11 MPa and temperature from −25 to +70 °C, and in the CGT-02 HT version up to +120 °C. This is the manufacturer's main device for commercial and process metering in gas transmission and distribution systems, at cross-border metering stations, at large industrial consumers (chemical plants, steelworks, industrial agglomerations), and also in boiler houses and at small enterprises.

The design gives high accuracy with minimal pressure losses and compact piping: for commercial metering stations an inlet straight section of only 2×DN is enough according to EN 12261 (annex B) and recommendation OIML R32-89 (annex A). The meter is resistant to flow disturbances. The error is better than the EN 12261 requirements. In the lower range Qmin–Qt it is less than ±2 %, in the main range Qt–Qmax less than ±1 %. The measuring range is 1:20 in the standard version, 1:30 for DN 80 and above, and 1:50 for DN 100 and above at an operating pressure of 2.0 MPa and higher.

The range covers sizes from G65 to G6500 (Qmax up to 10 000 m³/h) and nominal diameters DN 50–400, others on request. Flanged connections are made for PN10, PN16, PN20 (ANSI 150), PN25, PN40, PN50 (ANSI 300), PN64, PN100 and PN110 (ANSI 600), which corresponds to a maximum operating pressure from 1.0 to 11 MPa.

The rotating counter mechanism makes reading easier in any installation position. The mechanism has two reed and two inductive low-frequency LF pulse sensors and two high-frequency HF sensors, and the housing has four more HF sensors. A mechanical output for a CWSL encoder is possible. In this way metering can be run at the supplier and the consumer at the same time, and CMK-03 volume correctors or automation systems can be connected. Two pressure tappings, sockets for gas temperature sensors, installation of the oil pump at the front or rear and a vertical version are provided.

Besides natural gas, CGT-02 is used for technical gases, including air, propane-butane, acetylene, hydrogen, and also cleaned and dried biogas. The HT version is used in mine degassing plants. Explosion protection is Ex II 2G Ex ia IIB T5 Gb, to order Ex ia IIC T5 Gb. The meters comply with the MID, PED, ATEX and EMC directives. The type approval was issued by the German PTB.

Technical specifications

SizesG65…G6500, Qmax up to 10 000 m³/h
Nominal diameterDN 50 … DN 400 (others on request)
Maximum operating pressure1.0 MPa (PN10) … 11 MPa (PN110 / ANSI 600); flanges PN10–PN110, ANSI 150–600
Measuring range1:20 (standard), 1:30 for ≥DN80, 1:50 for ≥DN100 at p ≥ 2.0 MPa
ErrorQmin–Qt < ±2 %, Qt–Qmax < ±1 % (better than the EN 12261 requirements)
Gas temperature−25…+70 °C; HT version up to +120 °C
Inlet straight section2×DN (EN 12261 annex B, OIML R32-89 annex A)
Explosion protectionEx II 2G Ex ia IIB T5 Gb (standard), Ex ia IIC T5 Gb (special)
Pulse outputsin the counter mechanism 2 LF reed, 2 LF inductive, 2 HF; 4 HF on the housing
ComplianceMID 2014/32/EU, PED 2014/68/EU, ATEX 2014/34/EU, EMC 2014/30/EU; type approval PTB

Request a price and lead time

CGT-02 — gas turbine meter DN 50–400, operating pressure up to 11 MPa. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What pressure and temperature range does CGT-02 have?

Pressure from atmospheric up to 11 MPa, gas temperature from −25 to +70 °C. The CGT-02 HT version works up to +120 °C.

What straight section is needed before the meter?

For commercial metering stations 2×DN is enough according to EN 12261 (annex B) and OIML R32-89 (annex A). The meter is resistant to flow disturbances.

What are the measuring ranges and the error?

The range is 1:20 in the standard version, 1:30 for DN 80 and above, 1:50 for DN 100 and above at a pressure of 2.0 MPa and higher. The error is less than ±2 % in the range Qmin–Qt and less than ±1 % in the range Qt–Qmax.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides