International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TMS-Elite Transformer Monitoring Package with Partial Discharge and Fibre Optic Sensing

The top package in the transformer monitoring family, meant for units that simply must not fail. Partial discharge and fibre optic monitoring sit alongside the full fault library, with real-time alerts so staff can step in early.

Package
TMS-Elite
Technologies
partial discharge monitoring; fibre optic monitoring
OLTC/DETC
contact resistance; liquid insulation; motor drive; control
Windings
general overheating; paper insulation; local overheating 1 and 2

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Where TMS-Pro relies mainly on dissolved gas data, TMS-Elite adds direct measurement: partial discharge monitoring and fibre optic sensing inside the transformer. Every failure mode in the manufacturer's library is covered, and alerts arrive in real time.

Two groups of faults are new compared with the Pro tier. In the windings there is type 2 local overheating, meaning turn-to-turn faults and bad joints. For the liquid insulation there is a complete block: oil deterioration from moisture contamination, oxygen ingress and particles, tank overheating, design problems and oil overfill.

Everything else carries over. Tap changers, both OLTC and DETC, are checked for contact resistance, liquid insulation condition, motor drive failure and control failure. Windings are watched for general overheating, paper insulation ageing and type 1 local overheating; the core for over-excitation, steel joint opening and loss of shield or core earthing; the cooling plant for configuration errors, fan, radiator and pump faults and temperature sensor failure.

Bushings are added through the optional module, which detects internal contact problems, partial breakdowns, core insulation deterioration and contamination or discharge on the porcelain. Analytics software is supplied with the hardware.

This tier is chosen for critical transmission transformers and generator transformers where an outage, or a failure endangering personnel, is not acceptable. For a proposal, send nameplate data, tap changer type, cooling arrangement and whether provision for fibre optic probes already exists.

Technical specifications

PackageTMS-Elite
Technologiespartial discharge monitoring; fibre optic monitoring
OLTC/DETCcontact resistance; liquid insulation; motor drive; control
Windingsgeneral overheating; paper insulation; local overheating 1 and 2
Coreover-excitation; steel joint opening; loss of shield and core earthing
Cooling systemconfiguration; fans; radiators; pumps; temperature sensors
Liquid insulationmoisture; oxygen; particles; tank overheating; design problem; oil overfill
Optionbushing monitoring module
Alertsreal time
Applicationstransmission transformers, generator transformers

How it compares with similar models

ParameterTMS-Elite Transformer Monitoring Package with Partial Discharge and Fibre Optic SensingTMS-Pro Multi-Gas Transformer Monitoring Package with Cooling and Tap Changer DiagnosticsTMS-Core Entry-Level Transformer Condition Monitoring PackageBC 24 Externally Mounted Partial Discharge Coupler for GIS Retrofit
PackageTMS-EliteTMS-ProTMS-Core—
Windingsgeneral overheating; paper insulation; local overheating 1 and 2general overheating; paper insulation (moisture, oxygen); local overheating 1general overheating; paper insulation ageing (oxygen, moisture); local overheating—

Request a price and lead time

TMS-Elite Transformer Monitoring Package with Partial Discharge and Fibre Optic Sensing. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How does TMS-Elite differ from TMS-Pro?

It adds partial discharge and fibre optic monitoring, type 2 local overheating in the windings and a full liquid insulation diagnostic block.

Which oil-related faults are detected?

Oil deterioration from moisture, oxygen ingress and particles, tank overheating, design problems and oil overfill.

When is TMS-Elite the right choice?

For critical transmission and generator transformers whose failure cannot be tolerated.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides