TMS-Elite Transformer Monitoring Package with Partial Discharge and Fibre Optic Sensing
The top package in the transformer monitoring family, meant for units that simply must not fail. Partial discharge and fibre optic monitoring sit alongside the full fault library, with real-time alerts so staff can step in early.
- Package
- TMS-Elite
- Technologies
- partial discharge monitoring; fibre optic monitoring
- OLTC/DETC
- contact resistance; liquid insulation; motor drive; control
- Windings
- general overheating; paper insulation; local overheating 1 and 2
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Where TMS-Pro relies mainly on dissolved gas data, TMS-Elite adds direct measurement: partial discharge monitoring and fibre optic sensing inside the transformer. Every failure mode in the manufacturer's library is covered, and alerts arrive in real time.
Two groups of faults are new compared with the Pro tier. In the windings there is type 2 local overheating, meaning turn-to-turn faults and bad joints. For the liquid insulation there is a complete block: oil deterioration from moisture contamination, oxygen ingress and particles, tank overheating, design problems and oil overfill.
Everything else carries over. Tap changers, both OLTC and DETC, are checked for contact resistance, liquid insulation condition, motor drive failure and control failure. Windings are watched for general overheating, paper insulation ageing and type 1 local overheating; the core for over-excitation, steel joint opening and loss of shield or core earthing; the cooling plant for configuration errors, fan, radiator and pump faults and temperature sensor failure.
Bushings are added through the optional module, which detects internal contact problems, partial breakdowns, core insulation deterioration and contamination or discharge on the porcelain. Analytics software is supplied with the hardware.
This tier is chosen for critical transmission transformers and generator transformers where an outage, or a failure endangering personnel, is not acceptable. For a proposal, send nameplate data, tap changer type, cooling arrangement and whether provision for fibre optic probes already exists.
Technical specifications
| Package | TMS-Elite |
|---|---|
| Technologies | partial discharge monitoring; fibre optic monitoring |
| OLTC/DETC | contact resistance; liquid insulation; motor drive; control |
| Windings | general overheating; paper insulation; local overheating 1 and 2 |
| Core | over-excitation; steel joint opening; loss of shield and core earthing |
| Cooling system | configuration; fans; radiators; pumps; temperature sensors |
| Liquid insulation | moisture; oxygen; particles; tank overheating; design problem; oil overfill |
| Option | bushing monitoring module |
| Alerts | real time |
| Applications | transmission transformers, generator transformers |
How it compares with similar models
| Parameter | TMS-Elite Transformer Monitoring Package with Partial Discharge and Fibre Optic Sensing | TMS-Pro Multi-Gas Transformer Monitoring Package with Cooling and Tap Changer Diagnostics | TMS-Core Entry-Level Transformer Condition Monitoring Package | BC 24 Externally Mounted Partial Discharge Coupler for GIS Retrofit |
|---|---|---|---|---|
| Package | TMS-Elite | TMS-Pro | TMS-Core | — |
| Windings | general overheating; paper insulation; local overheating 1 and 2 | general overheating; paper insulation (moisture, oxygen); local overheating 1 | general overheating; paper insulation ageing (oxygen, moisture); local overheating | — |
Request a price and lead time
TMS-Elite Transformer Monitoring Package with Partial Discharge and Fibre Optic Sensing. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How does TMS-Elite differ from TMS-Pro?
It adds partial discharge and fibre optic monitoring, type 2 local overheating in the windings and a full liquid insulation diagnostic block.
Which oil-related faults are detected?
Oil deterioration from moisture, oxygen ingress and particles, tank overheating, design problems and oil overfill.
When is TMS-Elite the right choice?
For critical transmission and generator transformers whose failure cannot be tolerated.
Similar equipment from other manufacturers