International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

BC 24 Externally Mounted Partial Discharge Coupler for GIS Retrofit

A partial discharge coupler for adding PD monitoring to gas-insulated switchgear that is already in service. BC 24 is fitted on the outer face of the GIS barriers, so nothing inside the gas enclosure is disturbed.

Designation
BC 24
Type
partial discharge coupler
Purpose
partial discharge monitoring of GIS
Mounting
external, on GIS barriers

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Retrofitting partial discharge monitoring to an existing GIS often stalls on one question: who wants to open a gas compartment just to install a sensor? BC 24 avoids that altogether. The coupler is fitted to the outside of the barriers between compartments, which makes the job quick and non-invasive, with no degassing, no opening of the enclosure and no change to the switchgear itself.

It belongs to the PD accessories group. The coupler takes up the signal produced by discharge activity inside the switchgear and passes it on to the measuring equipment of the monitoring system.

Sites that benefit most are substations whose GIS was installed without built-in PD sensors and which now need condition data before planning maintenance. How many couplers are needed, and where they go, depends on the switchgear layout and on which compartments the operator wants covered.

To size a retrofit we ask for the GIS type and voltage level, the number of bays, and drawings or photographs of the barriers at the candidate mounting points. Please attach these to your enquiry.

Technical specifications

DesignationBC 24
Typepartial discharge coupler
Purposepartial discharge monitoring of GIS
Mountingexternal, on GIS barriers
Installationnon-invasive, gas compartments stay closed
Applicationretrofit to GIS in service
CategoryPD accessories

How it compares with similar models

ParameterBC 24 Externally Mounted Partial Discharge Coupler for GIS RetrofitInternal Coupler, internal partial discharge sensor for GIS switchgearWindow Coupler UHF Partial Discharge Sensor for Retrofitting Gas Insulated Switchgear (GIS)Gen3 PDM Online Partial Discharge and SF6 Gas Density Monitoring for GIS Substations
Typepartial discharge couplerinternal partial discharge sensor (coupler)Window-mounted partial discharge sensor (coupler)—
Purposepartial discharge monitoring of GISpartial discharge monitoringRetrofitting partial discharge monitoring to switchgearon-line partial discharge and gas density monitoring of GIS
Installationnon-invasive, gas compartments stay closedusually at the factory during GIS assembly—new GIS and retrofit
Applicationretrofit to GIS in servicegas insulated switchgear (GIS)Gas insulated switchgear (GIS) with inspection windows—

Request a price and lead time

BC 24 Externally Mounted Partial Discharge Coupler for GIS Retrofit. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Does a gas compartment have to be opened to fit BC 24?

No. The coupler goes on the outside of the GIS barriers, so installation is non-invasive.

What is BC 24 mainly used for?

Adding partial discharge monitoring to gas-insulated switchgear that is already in service and has no built-in PD sensors.

What information is needed to plan the number of couplers?

The GIS type and voltage level, the number of bays and compartments to be covered, and drawings or photos of the barriers.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides