BC 24 Externally Mounted Partial Discharge Coupler for GIS Retrofit
A partial discharge coupler for adding PD monitoring to gas-insulated switchgear that is already in service. BC 24 is fitted on the outer face of the GIS barriers, so nothing inside the gas enclosure is disturbed.
- Designation
- BC 24
- Type
- partial discharge coupler
- Purpose
- partial discharge monitoring of GIS
- Mounting
- external, on GIS barriers
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Retrofitting partial discharge monitoring to an existing GIS often stalls on one question: who wants to open a gas compartment just to install a sensor? BC 24 avoids that altogether. The coupler is fitted to the outside of the barriers between compartments, which makes the job quick and non-invasive, with no degassing, no opening of the enclosure and no change to the switchgear itself.
It belongs to the PD accessories group. The coupler takes up the signal produced by discharge activity inside the switchgear and passes it on to the measuring equipment of the monitoring system.
Sites that benefit most are substations whose GIS was installed without built-in PD sensors and which now need condition data before planning maintenance. How many couplers are needed, and where they go, depends on the switchgear layout and on which compartments the operator wants covered.
To size a retrofit we ask for the GIS type and voltage level, the number of bays, and drawings or photographs of the barriers at the candidate mounting points. Please attach these to your enquiry.
Technical specifications
| Designation | BC 24 |
|---|---|
| Type | partial discharge coupler |
| Purpose | partial discharge monitoring of GIS |
| Mounting | external, on GIS barriers |
| Installation | non-invasive, gas compartments stay closed |
| Application | retrofit to GIS in service |
| Category | PD accessories |
How it compares with similar models
| Parameter | BC 24 Externally Mounted Partial Discharge Coupler for GIS Retrofit | Internal Coupler, internal partial discharge sensor for GIS switchgear | Window Coupler UHF Partial Discharge Sensor for Retrofitting Gas Insulated Switchgear (GIS) | Gen3 PDM Online Partial Discharge and SF6 Gas Density Monitoring for GIS Substations |
|---|---|---|---|---|
| Type | partial discharge coupler | internal partial discharge sensor (coupler) | Window-mounted partial discharge sensor (coupler) | — |
| Purpose | partial discharge monitoring of GIS | partial discharge monitoring | Retrofitting partial discharge monitoring to switchgear | on-line partial discharge and gas density monitoring of GIS |
| Installation | non-invasive, gas compartments stay closed | usually at the factory during GIS assembly | — | new GIS and retrofit |
| Application | retrofit to GIS in service | gas insulated switchgear (GIS) | Gas insulated switchgear (GIS) with inspection windows | — |
Request a price and lead time
BC 24 Externally Mounted Partial Discharge Coupler for GIS Retrofit. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Does a gas compartment have to be opened to fit BC 24?
No. The coupler goes on the outside of the GIS barriers, so installation is non-invasive.
What is BC 24 mainly used for?
Adding partial discharge monitoring to gas-insulated switchgear that is already in service and has no built-in PD sensors.
What information is needed to plan the number of couplers?
The GIS type and voltage level, the number of bays and compartments to be covered, and drawings or photos of the barriers.
Similar equipment from other manufacturers