PCS-996R / PCS-996RC / PCS-986 disturbance recorders (DFR) and the PCS-9013 management system

Disturbance recorders capture electrical parameters and the sequence of events during faults and disturbances in the power system. They combine scattered records of individual protection terminals into a single picture of the process and simplify fault analysis, verification of protection and automation operation, and investigation of incidents. The line is complemented by the PCS-9013 system, which manages the recorders of substations and power plants.

PCS-996R
48 analog and 60 binary channels in one unit
PCS-996RC + PCS-996RA
distributed DFR: up to 4 acquisition units, up to 192 analog and 384 binary channels
Fault recording
9600 Hz
Continuous recording
1000/1200 Hz, 24 h, archive up to 7 days

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The PCS-996R works as a multifunction recorder for substations. One unit has 48 analog and 60 binary channels, and time is synchronized from an external source. Several recording modes are provided. Fault recording runs at 9600 Hz for short transients, continuous recording at 1200 Hz for medium-term dynamic processes, and slow recording at 1–50 Hz for long-term power quality monitoring. A separate selective recording automatically extracts the channels of the faulted bay into a compact file.

Recording is triggered by exceeding and jumps of phase voltages and currents, negative- and zero-sequence voltage and current, frequency deviation and df/dt, power swings and changes of binary inputs. Continuous 24-hour recording is possible.

The PCS-996RC is built as a distributed recorder. The PCS-996RC control unit is connected by point-to-point optical links to the PCS-996RA acquisition units, each of which has 48 analog and 96 binary channels. A typical configuration consists of one control unit and two acquisition units (96 analog and 192 binary channels), and the maximum one of four acquisition units, up to 192 analog and 384 binary channels. Continuous recording runs around the clock at 1000 Hz for a 50 Hz network with an archive of up to 7 days, and long-term recording of RMS values at 1 Hz is stored for up to 3 months.

The PCS-986 records the parameters of generator-transformer units and the operation of protection and control devices at power plants. Besides voltage and current triggers, it starts on a jump in and exceeding of the limits of the DC component, the third harmonic, overexcitation, reverse power, differential current of transformers, the generator or the excitation transformer, and low-frequency overcurrent during unit start-up and shutdown. The block architecture allows hardware and software to be expanded, and a 16-bit parallel ADC digitizes all channels simultaneously.

The PCS-9013 manages recorders centrally or in a distributed way. The system collects data from up to 1500 recorders over IEC 61850, FTP and IEC 60870-5-103, performs configuration and setting changes, status monitoring, remote control, synchronization and reset, waveform analysis, sends notifications by e-mail and SMS and has web access. All records are stored in COMTRADE format, and time is synchronized over IRIG-B.

Technical specifications

PCS-996R48 analog and 60 binary channels in one unit
PCS-996RC + PCS-996RAdistributed DFR: up to 4 acquisition units, up to 192 analog and 384 binary channels
Fault recording9600 Hz
Continuous recording1000/1200 Hz, 24 h, archive up to 7 days
Long-term recording1–50 Hz / RMS values at 1 Hz, archive up to 3 months
PCS-986DFR for generator-transformer units of power plants
PCS-9013management system for up to 1500 DFRs, IEC 61850, FTP, IEC 60870-5-103
FormatCOMTRADE, IRIG-B synchronization

Request a price and lead time

PCS-996R / PCS-996RC / PCS-986 disturbance recorders (DFR) and the PCS-9013 management system. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)9030 39 00 00
HS, 6 digits9030 39
CN (EU)9030 39 00
HTSUS (USA)9030 39 01 00
China customs tariff9030 39 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

How many channels does the distributed PCS-996RC recorder have?

A typical configuration with two acquisition units has 96 analog and 192 binary channels. At most, four acquisition units are connected to the control unit, which gives up to 192 analog and 384 binary channels.

At what rate does the PCS-996R record fault processes?

Fault recording runs at 9600 Hz and continuous recording at 1200 Hz. For long-term monitoring there is slow recording at 1–50 Hz.

How many recorders can be connected to the PCS-9013 system?

Up to 1500 recorders over IEC 61850, FTP and IEC 60870-5-103. The system performs remote configuration, status monitoring and waveform analysis.