International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

PQ-Box 50 / 150 / 200 / 300 — portable Class A power quality analyzers

PQ-Box 50, 150, 200 and 300 are mobile Class A power quality analyzers to IEC 61000-4-30 Ed.4. They work together with power and transient recorders used to find the causes of network disturbances on site, from a building service entrance to high-voltage networks.

Class
A to IEC 61000-4-30 Ed.4
Networks
LV, MV and HV (via voltage transformers), including the 16.7 Hz traction network
PQ-Box 150
harmonics up to 9 kHz
PQ-Box 200
transient recording at 4 MHz

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The devices connect directly to LV networks and to MV and HV through voltage transformers; the 16.7 Hz traction network is also supported. The models differ in depth of analysis. PQ-Box 150 measures harmonics up to 9 kHz, PQ-Box 200 records transients at 4 MHz, PQ-Box 300 performs continuous spectrum analysis up to 170 kHz. Data is transferred over WLAN and processed in WinPQ mobil software.

Technical specifications

ClassA to IEC 61000-4-30 Ed.4
NetworksLV, MV and HV (via voltage transformers), including the 16.7 Hz traction network
PQ-Box 150harmonics up to 9 kHz
PQ-Box 200transient recording at 4 MHz
PQ-Box 300continuous spectrum analysis up to 170 kHz
CommunicationWLAN, WinPQ mobil software

Request a price and lead time

PQ-Box 50 / 150 / 200 / 300 — portable Class A power quality analyzers. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)9030 39 00 00
HS, 6 digits9030 39
CN (EU)9030 39 00
HTSUS (USA)9030 39 01 00
China customs tariff9030 39 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Which accuracy class do PQ-Box analyzers meet?

Class A to IEC 61000-4-30 Ed.4.

Can measurements be made in MV and HV networks?

Yes, through voltage transformers. The 16.7 Hz traction network is also supported.

Which model suits transient and high-frequency disturbance analysis?

PQ-Box 200 records transients at 4 MHz, PQ-Box 300 performs continuous spectrum analysis up to 170 kHz.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides