WicketPaq Temperature Profiler for Wicket Ovens with DP5660 Six-Channel Logger
WicketPaq monitors the temperature of the metal sheet and the air in wicket ovens used to make three-piece cans. A DP5660 logger in a thermal barrier travels through the oven with a test sheet and records six channels. The range is -200 to 1370 °C with an accuracy of ±0.5 °C.
- Logger
- DP5660
- Channels
- 6
- Temperature range
- -200 to 1370 °C
- Accuracy
- ±0.5 °C
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The system is used on print and lacquer lines for three-piece cans, where sheets dry in a wicket oven. The recorded temperature profile shows whether the paint and varnish have cured, helps find the causes of under- or over-drying, checks how evenly the sheet is heated, and reveals zones of heat leakage and excessive air turbulence. Profiles let engineers set process parameters without a series of trial runs and repeated checks.
Thermocouples are attached to the sheet surface, and the logger travels through the oven with the sheet, recording surface and air temperature. The thermal barrier clips onto the moving sheet, so the system and the test sheet can be fitted quickly without stopping production. Its shape, size and construction are designed to pass through a wicket oven without changing how the oven runs.
The DP5660 logger has six channels, a measuring range of -200 to 1370 °C, an accuracy of ±0.5 °C and a resolution of ±0.1 °C. The sampling interval is set from 0.05 s to 10 min. Recording is started with the Start/Stop buttons, by time or by a temperature threshold. The logger runs from a NiMH battery that the user replaces.
Thermal barriers come in two versions. The TB0045 weighs 1.5 kg and has dimensions of 48×185×233 mm, lasting 80 min at 100 °C; at 150 °C the figure is 45 min, at 200 °C 35 min, and at 250 °C 30 min. The TB0046, weighing 2.5 kg, measures 70×172×240 mm and runs 120 min at 100 °C, with 60 min at 150 °C, 45 min at 200 °C, 35 min at 250 °C, then 25 min at 280 °C. The larger barrier suits longer passes and higher oven temperatures.
Analysis software draws a contour chart of sheet temperature, reference curves and tolerances, runs statistical process control (SPC), issues alarms based on the results, builds reports and sends them by e-mail.
Technical specifications
| Logger | DP5660 |
|---|---|
| Channels | 6 |
| Temperature range | -200 to 1370 °C |
| Accuracy | ±0.5 °C |
| Resolution | ±0.1 °C |
| Sampling interval | 0.05 s to 10 min |
| Recording start | Start/Stop buttons, time or temperature |
| Battery | NiMH, replaced by the user |
| Thermal barrier TB0045 | 1.5 kg, 48×185×233 mm |
| Thermal barrier TB0046 | 2.5 kg, 70×172×240 mm |
| TB0045 endurance | 80 min at 100 °C, 30 min at 250 °C |
| TB0046 endurance | 120 min at 100 °C, 25 min at 280 °C |
Part numbers
Show all part numbers (3)
DP5660, TB0045, TB0046
Request a price and lead time
WicketPaq Temperature Profiler for Wicket Ovens with DP5660 Six-Channel Logger. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How long does the thermal barrier last in the oven?
The TB0045 runs for 80 min at 100 °C and 30 min at 250 °C. The TB0046 lasts 120 min at 100 °C and 25 min at 280 °C.
Does the line have to be stopped for measurement?
No. The thermal barrier clips onto the moving sheet and passes through the oven without changing how the oven runs.
How often does the logger record the temperature?
The sampling interval is set from 0.05 s to 10 min. Recording is started by the buttons, by time or by a temperature threshold.