5000 Process Moisture Analyser, Quartz Crystal, 0 to 1000 ppmv

The 5000 measures moisture continuously in gases and vapours using a differential quartz crystal principle. It has an explosion-protected field unit, a controller up to 600 m away, and one to four sample streams.

Measuring principle
differential, quartz crystal, 30 second sample and reference cycle
Range
0 to 1000 ppmv
Sensitivity
0.1 ppmv or 0.5% of reading
Accuracy
±1 ppmv or 5% of reading

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The 5000 measures moisture continuously in process gases and vapours. It is a sensitive analyser for process applications that need reliable readings, and it shows few cross-influences, so no compensation for process temperature or pressure is needed. Typical applications include catalytic reforming, moisture in olefins and natural gas, hydrocarbon processing and the gas industry.

Measurement is based on the change in oscillation frequency of a hygroscopically sensitised quartz crystal. The crystal is alternately exposed to the moist sample and to a dry reference gas in 30 second periods, and the frequency difference gives the moisture value. The reference gas is prepared by an external 3A molecular sieve dryer. An internal moisture generator, 20 ppmv nominal with a 3 ppmv low option, and continuous diagnostics confirm that the analyser is working correctly.

The calibrated range is 0 to 1000 ppmv. Sensitivity is 0.1 ppmv or 0.5% of reading, accuracy is ±1 ppmv or 5% of reading, and reproducibility is 0.2 ppmv or 1% of reading, in each case whichever is greater. For measurements below 5 ppmv a super-activated dryer is required, and with it the accuracy in the 0 to 5 ppmv range is 0.1 ppmv on certain applications.

The field unit contains the measuring cell, switching valves and electronics, while the flowmeter, flow regulating valves and back-pressure regulator are fitted externally. The controller has a vacuum fluorescent display of four lines by 20 characters and three access levels, and it can be installed up to 600 m from the field unit. Controllers are available for wall mounting, 19 inch rack mounting, panel cut-out or in a NEMA 4X enclosure.

The sample is supplied at 207 to 690 kPa, or up to 137.9 bar with an optional pressure reducer, and at a temperature of 0 to 100 °C, with a flow of 1500 ml/min. The single-point system analyses one stream, while the multi-point version handles up to four sample streams with a programmable switching time from 2 minutes per stream. Outputs are two 4 to 20 mA signals with a user-set span, one of them auto-ranging, plus an RS485 port and alarm contacts. The field unit operates from -20 to 50 °C, or from -40 to 50 °C with the optional electric heater, and carries IP56 protection. It is certified to NEC/CEC Class I, Division 2, Groups A, B, C, D, T4, with optional Class I, Division 1 and ATEX II 2 G EEx d IIC T6.

Technical specifications

Measuring principledifferential, quartz crystal, 30 second sample and reference cycle
Range0 to 1000 ppmv
Sensitivity0.1 ppmv or 0.5% of reading
Accuracy±1 ppmv or 5% of reading
Reproducibility0.2 ppmv or 1% of reading
Inlet pressure207 to 690 kPa (30 to 100 psi)
Operating pressure103 kPa (15 psi)
Sample temperature0 to 100 °C
Sample flow1500 ml/min at 103 kPa
Number of streams1 to 4
Outputs2 × 4 to 20 mA, RS485, alarm contacts
Displayvacuum fluorescent, 4 lines of 20 characters
Distance, field unit to controllerup to 600 m
Field unit power100/115/230 V ±10%, 50/60 Hz, 175 W
Controller power95 to 230 V ±10%, 47 to 63 Hz, 75 W
Ambient temperature, field unit-20 to 50 °C, or -40 to 50 °C with electric heater
Ambient temperature, controller-10 to 50 °C
Moisture generator20 ppmv, optional 3 ppmv
Single-point field unit size770 x 1530 x 460 mm
Hazardous area ratingClass I, Division 2, Groups A, B, C, D, T4; ATEX II 2 G EEx d IIC T6

Request a price and lead time

5000 Process Moisture Analyser, Quartz Crystal, 0 to 1000 ppmv. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Does the analyser need compensation for process temperature or pressure?

No. The differential measurement principle works without compensation for process temperature or pressure.

How many sample streams can one analyser measure?

The single-point system handles one stream and the multi-point system up to four, with switching time programmable from 2 minutes per stream.

What is needed for measurements below 5 ppmv?

A super-activated dryer. With it, accuracy in the 0 to 5 ppmv range is 0.1 ppmv on certain applications.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides