5100P TDLAS transportable analyser for moisture and CO2 in gas, battery powered, Zone 2

The 5100P TDLAS is a transportable analyser that uses tunable diode laser absorption spectroscopy to measure moisture or carbon dioxide in natural gas and other process streams. The unit has a built-in sample conditioning system, runs on a battery, and is approved for Class I Division 2 and ATEX/IECEx Zone 2 areas.

Measurement method
Tunable diode laser absorption spectroscopy (TDLAS)
Moisture in natural gas
0-2500 ppmv
Moisture in hydrocarbons and recycle hydrogen
0-1000 ppmv
Moisture in CO2
0-100 ppmv or 0-3500 ppmv

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The 5100P suits sites where a fixed analyser is impractical, such as remote facilities, wellheads and pipelines, and it is also used to check the readings of permanently installed analysers on site. Each unit is set up for one duty: moisture in natural gas in the range 0-2500 ppmv, moisture in hydrocarbon streams or recycle hydrogen in the range 0-1000 ppmv, moisture in CO2 in the range 0-100 ppmv or 0-3500 ppmv, or CO2 in natural gas in the range 0-2%.

The laser source and detector never touch the sample, so routine recalibration, sensor cleaning and contamination from gas impurities are avoided. Each unit is calibrated and verified at the factory. An internal reference cell prevents wavelength drift in the field, and a line-locking function continuously monitors the laser output. The photometer responds in under one second and T90 is reached in under 15 seconds at 2 SLPM, with no settling time needed for the sensor.

Accuracy and repeatability for moisture in natural gas are 2% of reading or ±4 ppmv, and for CO2 in natural gas they are ±2% of reading or 200 ppmv. Connection is made through a 1/8-inch compression fitting, after which the unit is powered up and gas is supplied. Start-up takes about one minute. The sample panel comes in three forms: a standard panel with a built-in regulator for inlet pressures of 1.03-17.2 barg, a low-pressure panel for 0.06-1.03 barg, or no panel at all for 0.06-0.7 barg. Recommended sample flow is 1-2 SLPM.

Power comes from a sealed lead acid battery giving at least eight hours of use. When the battery is flat, the unit runs from 110-240 VAC mains, which also charges it. The stainless steel IP 65 enclosure measures 25.1 x 20.9 x 40.1 cm and weighs about 13.2 kg. Ambient and sample temperatures range from -20 to +50ºC, and the Ex nA ic op pr IIC T3 Gc marking covers use in hazardous areas. A 20 x 4 backlit LCD, a 19-key keypad and a USB port complete the interface.

Technical specifications

Measurement methodTunable diode laser absorption spectroscopy (TDLAS)
Moisture in natural gas0-2500 ppmv
Moisture in hydrocarbons and recycle hydrogen0-1000 ppmv
Moisture in CO20-100 ppmv or 0-3500 ppmv
CO2 in natural gas0-2%
Accuracy (moisture in natural gas)2% of reading or ±4 ppmv
Response timeUnder 1 s photometer response; under 15 s to T90 at 2 SLPM
Sample flow1-2 SLPM
Sample panel inlet pressure1.03-17.2 barg (standard), 0.06-1.03 barg (low pressure), 0.06-0.7 barg (no panel)
Ambient and sample temperature-20...+50ºC
Sample wetted parts304 and 316 stainless steel, SiO2, EPDM
PowerSealed lead acid battery, at least 8 h; charging 110-240 VAC 50-60 Hz
Interface20x4 LCD, 19-key keypad, USB
Ingress protectionIP 65
Explosion protectionEx nA ic op pr IIC T3 Gc; Class I Division 2, Groups A-D, T3
Dimensions25.1 x 20.9 x 40.1 cm
WeightApproximately 13.2 kg

Request a price and lead time

5100P TDLAS transportable analyser for moisture and CO2 in gas, battery powered, Zone 2. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How long does the 5100P run on its battery?

At least eight hours from the sealed lead acid battery. When the battery is flat, the unit runs from 110-240 VAC mains.

Which sample panel should I choose?

The standard panel has a regulator and accepts 1.03-17.2 barg, the low-pressure panel accepts 0.06-1.03 barg, and without a panel the inlet is allowed at 0.06-0.7 barg.

Can the 5100P be used in a potentially explosive area?

Yes, the unit carries the Ex nA ic op pr IIC T3 Gc marking and is approved for Class I Division 2 and ATEX/IECEx Zone 2 areas.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides