5100P TDLAS transportable analyser for moisture and CO2 in gas, battery powered, Zone 2
The 5100P TDLAS is a transportable analyser that uses tunable diode laser absorption spectroscopy to measure moisture or carbon dioxide in natural gas and other process streams. The unit has a built-in sample conditioning system, runs on a battery, and is approved for Class I Division 2 and ATEX/IECEx Zone 2 areas.
- Measurement method
- Tunable diode laser absorption spectroscopy (TDLAS)
- Moisture in natural gas
- 0-2500 ppmv
- Moisture in hydrocarbons and recycle hydrogen
- 0-1000 ppmv
- Moisture in CO2
- 0-100 ppmv or 0-3500 ppmv
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The 5100P suits sites where a fixed analyser is impractical, such as remote facilities, wellheads and pipelines, and it is also used to check the readings of permanently installed analysers on site. Each unit is set up for one duty: moisture in natural gas in the range 0-2500 ppmv, moisture in hydrocarbon streams or recycle hydrogen in the range 0-1000 ppmv, moisture in CO2 in the range 0-100 ppmv or 0-3500 ppmv, or CO2 in natural gas in the range 0-2%.
The laser source and detector never touch the sample, so routine recalibration, sensor cleaning and contamination from gas impurities are avoided. Each unit is calibrated and verified at the factory. An internal reference cell prevents wavelength drift in the field, and a line-locking function continuously monitors the laser output. The photometer responds in under one second and T90 is reached in under 15 seconds at 2 SLPM, with no settling time needed for the sensor.
Accuracy and repeatability for moisture in natural gas are 2% of reading or ±4 ppmv, and for CO2 in natural gas they are ±2% of reading or 200 ppmv. Connection is made through a 1/8-inch compression fitting, after which the unit is powered up and gas is supplied. Start-up takes about one minute. The sample panel comes in three forms: a standard panel with a built-in regulator for inlet pressures of 1.03-17.2 barg, a low-pressure panel for 0.06-1.03 barg, or no panel at all for 0.06-0.7 barg. Recommended sample flow is 1-2 SLPM.
Power comes from a sealed lead acid battery giving at least eight hours of use. When the battery is flat, the unit runs from 110-240 VAC mains, which also charges it. The stainless steel IP 65 enclosure measures 25.1 x 20.9 x 40.1 cm and weighs about 13.2 kg. Ambient and sample temperatures range from -20 to +50ºC, and the Ex nA ic op pr IIC T3 Gc marking covers use in hazardous areas. A 20 x 4 backlit LCD, a 19-key keypad and a USB port complete the interface.
Technical specifications
| Measurement method | Tunable diode laser absorption spectroscopy (TDLAS) |
|---|---|
| Moisture in natural gas | 0-2500 ppmv |
| Moisture in hydrocarbons and recycle hydrogen | 0-1000 ppmv |
| Moisture in CO2 | 0-100 ppmv or 0-3500 ppmv |
| CO2 in natural gas | 0-2% |
| Accuracy (moisture in natural gas) | 2% of reading or ±4 ppmv |
| Response time | Under 1 s photometer response; under 15 s to T90 at 2 SLPM |
| Sample flow | 1-2 SLPM |
| Sample panel inlet pressure | 1.03-17.2 barg (standard), 0.06-1.03 barg (low pressure), 0.06-0.7 barg (no panel) |
| Ambient and sample temperature | -20...+50ºC |
| Sample wetted parts | 304 and 316 stainless steel, SiO2, EPDM |
| Power | Sealed lead acid battery, at least 8 h; charging 110-240 VAC 50-60 Hz |
| Interface | 20x4 LCD, 19-key keypad, USB |
| Ingress protection | IP 65 |
| Explosion protection | Ex nA ic op pr IIC T3 Gc; Class I Division 2, Groups A-D, T3 |
| Dimensions | 25.1 x 20.9 x 40.1 cm |
| Weight | Approximately 13.2 kg |
Request a price and lead time
5100P TDLAS transportable analyser for moisture and CO2 in gas, battery powered, Zone 2. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How long does the 5100P run on its battery?
At least eight hours from the sealed lead acid battery. When the battery is flat, the unit runs from 110-240 VAC mains.
Which sample panel should I choose?
The standard panel has a regulator and accepts 1.03-17.2 barg, the low-pressure panel accepts 0.06-1.03 barg, and without a panel the inlet is allowed at 0.06-0.7 barg.
Can the 5100P be used in a potentially explosive area?
Yes, the unit carries the Ex nA ic op pr IIC T3 Gc marking and is approved for Class I Division 2 and ATEX/IECEx Zone 2 areas.