WDG-V UOP oxygen analyser for CCR catalyst regeneration
The WDG-V UOP/RP measures low oxygen levels during continuous catalyst regeneration, where coke deposits are burnt off by oxidation. The zirconia cell resists halogen attack, and a nitrogen aspirator draws the sample and returns it to the process.
- Principle
- zirconium oxide, close-coupled, nitrogen aspirated
- Range
- 0–1% to 0–100% O2
- Accuracy
- ±0.75% of reading or ±0.05% O2, whichever is greater
- Response
- under 12 seconds (90% of a step change)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The analyser is used on continuous catalyst regeneration platforming units in refining and petrochemical plants. During regeneration, coke is burnt off the catalyst by oxidation, and the oxygen content must be held within set limits to avoid thermal damage to the catalyst. Some versions are also applied to combustion control, sulphur recovery units and tail gas treatment.
The sensor is attached directly to the process. A nitrogen-powered aspirator draws a sample of gas from the regenerator, and part of that sample passes the zirconia cell. Because the aspirator gas contains no oxygen, the sample can go back to the process without venting. The cell is made from specially treated zirconium oxide that withstands the corrosive effect of halogen oxidation. The cell operates at 680 °C, its heater is rated at 300 W and the housing is warmed by two 150 W cartridge heaters, while the wetted sample parts are heated to 200 °C. The reference gas is air at 20.9% O2.
The measuring range runs from 0–1% to 0–100% O2, with accuracy of ±0.75% of the reading or ±0.05% O2, whichever is greater. Response is under 12 seconds to 90% of a step change, and drift stays below 0.1% of cell output per month. Nitrogen consumption for the aspirator is 4.72–9.4 L/min (10–20 scfh). Process pressure variants are atmospheric, 35 psi or 110 psi, the sample dew point can reach 200 °C, and the probe is Hastelloy C in lengths of 46 or 69 cm, on a 3-inch class 300 mounting flange.
The WDG-V platform electronics are designed for SIL-2 safety systems and include extended diagnostics, predictive maintenance algorithms and early warning signals. The 4.2 inch colour display has a 19-key keypad, and there are three isolated 4–20, 0–20, 20–4 or 20–0 mA outputs plus five relays, two for system service and data validity and three for process use, rated at 0.5 A, 30 V and 10 VA. Communication is by Modbus RTU over RS-485 at 57.6 kbaud, a web interface over TCP/IP and a USB flash drive, and up to four analysers can feed a shared graphical operator panel.
The enclosure is IP65 with hinged doors that float for maintenance access, and it works from -20 to 60 °C. Power is 115 or 230 V AC ±10%, 47–63 Hz, up to 740 VA. For hazardous areas there are Class I, Division 2, groups A, B, C and D versions, and ATEX and IECEx II 3 G purged versions marked Ex pzc IIC T3 Gc, with purge air at 5.5–8.3 bar.
Technical specifications
| Principle | zirconium oxide, close-coupled, nitrogen aspirated |
|---|---|
| Range | 0–1% to 0–100% O2 |
| Accuracy | ±0.75% of reading or ±0.05% O2, whichever is greater |
| Response | under 12 seconds (90% of a step change) |
| Drift | under 0.1% of cell signal per month |
| Aspirator nitrogen | 4.72–9.4 L/min (10–20 scfh) |
| Process pressure | atmospheric, 35 psi or 110 psi |
| Sample dew point | up to 200 °C |
| Probe | Hastelloy C, 46 or 69 cm |
| Mounting flange | 3 inch, class 300 |
| Cell temperature | 680 °C |
| Analogue outputs | 3 isolated, 4–20 / 0–20 / 20–4 / 20–0 mA |
| Relays | 5 (2 system, 3 process), 0.5 A, 30 V |
| Communications | Modbus RTU (RS-485, 57.6 kbaud), TCP/IP, USB |
| Display | 4.2 inch colour, 19 keys |
| Enclosure | IP65 |
| Ambient temperature | -20 to 60 °C |
| Power | 115 or 230 V AC ±10%, 47–63 Hz, up to 740 VA |
| Explosion protection | Class I Div 2 groups A, B, C, D; ATEX/IECEx II 3 G, Ex pzc IIC T3 Gc |
Part numbers
Show all part numbers (2)
WDG-V UOP/RP, WDG-V UOP
Request a price and lead time
WDG-V UOP oxygen analyser for CCR catalyst regeneration. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Why can the sample be returned to the process?
A nitrogen-powered aspirator draws the sample, and its gas contains no oxygen, so the mixture goes back to the process without venting to the atmosphere.
Is the analyser suitable for safety instrumented systems?
The WDG-V electronics are designed for SIL-2 safety systems and offer extended diagnostics and predictive maintenance.
Which digital interfaces are supported?
Modbus RTU over RS-485 at 57.6 kbaud, a web interface over TCP/IP and a USB flash drive.