WDG-V HP Oxygen Analyser for Dusty Flue Gas up to 1537 °C
The WDG-V HP series measures excess oxygen in flue gas and, depending on the variant, combustibles and methane as well. It mounts directly on the process flange and draws its sample by natural convection without an ejector, which suits gas carrying heavy dust.
- Measuring principle
- Zirconium oxide cell (O2); catalytic detectors (CO+H2, CH4)
- Sampling
- Convective, no ejector
- O2 range
- 0–1% to 0–100%
- Combustibles range
- 0–2000 ppm (standard)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Plants that burn fuel in dusty conditions use this analyser to keep combustion under control. Typical sites include cement and lime kilns, rotary kilns, multiple hearth furnaces in glass and metals work, pharmaceutical heaters, power and steam boilers, black liquor recovery boilers in pulp mills and sludge incineration plants. Tighter control helps to cut NOx emissions and improve fuel efficiency.
The design builds on the earlier WDG-HPII unit. Gas is drawn into the internal path by the stack effect, and diffusion slows the flow near the probe, so dust does not wear the probe away and settles less in the sample path. Convection carries the sample through the internal channels without an ejector that could clog. The result combines the dust tolerance of an in situ probe with the temperature and corrosion resistance of an extractive system.
Oxygen is measured by a zirconium oxide cell stabilised with yttrium or calcium oxide, fitted with porous platinum electrodes and run at 695 °C, with air as the 20.9% O2 reference. Combustibles and methane are read by hot wire catalytic detectors. Ranges run from 0–1% to 0–100% for oxygen, from 0–2000 ppm for combustibles as standard, and from 0–1% to 0–5% for methane. Oxygen accuracy is ±0.75% of reading or ±0.05% O2, whichever is greater, and response to a step change is under 30 seconds for oxygen and under 45 seconds for combustibles and methane.
Four model codes cover the measurement choice. WDG-V HP measures oxygen only, WDG-VC HP measures oxygen and combustibles, WDG-VM HP measures oxygen and methane, and WDG-VCM HP covers all three. Probes are 316 stainless steel for gas up to 704 °C, 310 stainless steel up to 1024 °C or ceramic up to 1537 °C, in lengths of 61, 91 or 122 cm. The hinged NEMA 4X housing (IP65) operates from -20 to 60 °C at 10 to 90% humidity without condensation, at altitudes up to 5000 m.
Hazardous area versions carry Ex pzc IIC T3 Gc marking under ATEX and IECEx and are approved for Class I and Class II, Division 2 and Zone 2. Three isolated linear outputs can each be set to 4-20 mA, 0-20 mA, 20-4 mA or 20-0 mA. Five independent normally open alarms are fitted, two for system service and data validity and three for configurable process use. A 2-wire Modbus RTU link runs at 57.6 kBaud, and a separate contact input starts automatic calibration. Diagnostics track cell and detector age, cell resistance and when calibration is due. Power is 120 or 230 VAC ±10%, 47–63 Hz.
Technical specifications
| Measuring principle | Zirconium oxide cell (O2); catalytic detectors (CO+H2, CH4) |
|---|---|
| Sampling | Convective, no ejector |
| O2 range | 0–1% to 0–100% |
| Combustibles range | 0–2000 ppm (standard) |
| Methane range | 0–1% to 0–5% |
| O2 accuracy | ±0.75% of reading or ±0.05% O2 |
| Combustibles accuracy | ±2% of full scale or ±40 ppm |
| Response (90%) | O2 under 30 s; combustibles and methane under 45 s |
| Gas temperature and probe material | 704 °C / 316 SS; 1024 °C / 310 SS; 1537 °C / ceramic |
| Probe length | 61 cm, 91 cm, 122 cm |
| Analogue outputs | 3 isolated, 4-20 mA, 0-20 mA, 20-4 mA, 20-0 mA |
| Alarm relays | 5 (2 system, 3 process) |
| Digital interface | RS-485 Modbus RTU, 57.6 kBaud |
| Enclosure | NEMA 4X (IP65) |
| Ambient temperature | -20 to 60 °C |
| Hazardous area rating | Ex pzc IIC T3 Gc; Class I, II Division 2; Zone 2 |
| Supply voltage | 120 or 230 VAC ±10%, 47–63 Hz |
Part numbers
Show all part numbers (4)
WDG-V HP, WDG-VC HP, WDG-VM HP, WDG-VCM HP
Request a price and lead time
WDG-V HP Oxygen Analyser for Dusty Flue Gas up to 1537 °C. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Why does this analyser resist clogging by dust?
Sampling works by natural convection and the stack effect, with no ejector that dust could block. Diffusion also slows the gas near the probe, so less dust builds up in the internal sample path.
Which variant measures methane?
WDG-VM HP measures oxygen and methane, while WDG-VCM HP measures oxygen, combustibles and methane. The methane range runs from 0–1% to 0–5%.
Can the analyser be used in a hazardous area?
Yes. Versions are approved for Class I and Class II, Division 2 and Zone 2, and carry Ex pzc IIC T3 Gc marking under ATEX and IECEx.