WDG-V Flue Gas Analyser for O2, Combustibles and Methane, Gas up to 1648 °C, SIL 2

The WDG-V measures oxygen, combustibles (CO+H2) and methane in the flue gas of furnaces, boilers and thermal oxidisers. It is a close-coupled extractive analyser designed to SIL 2, and all of its parts can be serviced without removal from the process flange.

Measured components
O2, combustibles (CO+H2), methane (CH4)
Measuring principle
Zirconium oxide (O2); catalytic detectors (combustibles, CH4)
Flue gas temperature
Up to 1648 °C (3000 °F)
O2 range
0–1% to 0–100%

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

WDG-V analysers are used to control and tune combustion on process heaters, steam boilers, thermal oxidisers, cement and lime kilns, hydrocarbon processing, metals work, pharmaceutical plants and power stations. Their signals drive combustion control and also act as an extra protection layer in burner management systems, particularly during purge, light off and shutdown of boilers fired on natural gas.

The unit is extractive and close-coupled to the flange, so the sample is taken right at the measuring point, which keeps response quick even in gas at up to 1648 °C (3000 °F). The oxygen cell is zirconium oxide running at 680 °C. Combustibles and methane are measured by catalytic detectors in a block held at 225 °C, while the internal sample plumbing is kept above 200 °C. A built in flow sensor checks the integrity of the sampling system and refreshes its reading every 90 seconds. Two flame arrestors are fitted in the line.

The variants differ in what they measure. WDG-V reads oxygen only, WDG-VC adds combustibles, and WDG-VCM reads oxygen, combustibles and methane with an extra 50 W heater for the combustibles block. WDG-VRM is a 19 inch rack mounted version of 4U height. Probes come as standard 1/8 NPT, ceramic or long types, and the range also includes HP and /S models.

The analyser has three isolated linear current outputs, each set to 4-20 mA, 0-20 mA, 20-4 mA or 20-0 mA, and five independent normally open relays. Two are system relays for service and data validity, and three are configurable process alarms. A contact input starts remote automatic calibration. Communication is Modbus RTU over two-wire RS-485 at 57.6 kBaud, and Ethernet TCP/IP lets the unit be monitored from a service network or asset management system.

Power is 115 or 230 VAC ±10%, 47–63 Hz. Ambient temperature runs from -25 to 65 °C, or from -20 to 60 °C in hazardous areas, where the unit is approved for Class I Division 2, ATEX and IECEx Zone 2 and is purged with clean, dry instrument air at 30–50 psi. Sensor electronics comply with SIL 2 under IEC 61508 and IEC 61511. Continuous diagnostics track the state of the cell and detectors, and a service alarm tells the control or safety system when inspection is needed.

Technical specifications

Measured componentsO2, combustibles (CO+H2), methane (CH4)
Measuring principleZirconium oxide (O2); catalytic detectors (combustibles, CH4)
Flue gas temperatureUp to 1648 °C (3000 °F)
O2 range0–1% to 0–100%
O2 accuracy±0.75% of reading or ±0.05%, whichever is greater
Combustibles range0–500 ppm to 0–10,000 ppm; 0–2000 ppm standard
Combustibles accuracy±2% of full scale or ±40 ppm, whichever is greater
Methane range0–5%
T90 responseO2 under 11 s; combustibles and CH4 under 25 s
Analogue outputs3 isolated, 4–20 / 0–20 / 20–4 / 20–0 mA
Relays5 independent normally open, 0.5 A, 30 V
CommunicationModbus RTU at 57.6 kBaud, Ethernet TCP/IP
Sample pressure±10 in. water gauge
Supply voltage115 / 230 VAC ±10%, 47–63 Hz
Ambient temperature-25 to 65 °C; -20 to 60 °C in hazardous areas
Hazardous area ratingClass I Div 2, ATEX Zone 2, IECEx Zone 2
Functional safetySIL 2 (IEC 61508)

Part numbers

Show all part numbers (13)

WDG-V, WDG-VC, WDG-VCM, WDG-VM, WDG-VRM, WDG-V HP, WDG-VC HP, WDG-VCM HP, WDG-VM HP, WDG-V/S, WDG-VC/S, WDG-VCM/S, WDG-VM/S

Request a price and lead time

WDG-V Flue Gas Analyser for O2, Combustibles and Methane, Gas up to 1648 °C, SIL 2. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which version is needed to monitor methane during boiler light off?

WDG-VCM measures oxygen, combustibles and methane, with a methane range of 0–5% and a T90 response under 25 seconds.

Can the analyser be serviced without being removed from the process?

Yes. All parts are serviced without removing the analyser from the process flange, and continuous diagnostics show the state of the detectors.

How does the analyser connect to control and safety systems?

Through three isolated 4-20 mA outputs, five relays, Modbus RTU over RS-485 and Ethernet TCP/IP. The service alarm is passed to the safety system when inspection is due.