TRX Low Power Temperature Transmitter with 8 V Lift-off Voltage for Remote Oil and Gas Sites

TRX temperature transmitter with low power demand, intended for wellheads and gas transport sites powered by solar installations. It runs from 8 V, passes 20 mA through a 100 ohm load at 10 V, accepts any thermocouple or resistance thermometer and has approvals for hazardous areas.

Input
any thermocouple (TC) or RTD
Output signal
4-20 mA
Lift-off voltage
8 V
Load capability
20 mA into 100 ohm at 10 V

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Wellheads at oil and gas production and transport sites are often far from the grid, so instruments there are powered by solar installations with batteries. In winter the voltage of such a source drops, and measurement loops need instruments with minimal power requirements. The TRX is designed for exactly these conditions.

The TRX needs only 8 V of lift-off voltage. At a supply of 10 V it passes 20 mA through a 100 ohm load. Because the lift-off voltage is 8 V and the load adds a 2 V drop, the loop stays operational even when the battery voltage sags.

In a typical circuit a 10 to 24 V solar installation powers the 4-20 mA loop, and the temperature is passed to a gas flow computer. A 50 ohm resistor in the loop turns the current signal into a 0-1 V voltage, which the computer accepts directly. The circuit needs no separate power supply for the transmitter.

The universal input accepts any thermocouple (TC) or resistance temperature detector (RTD). In the described application it works with a four-wire platinum RTD of the WORM type. One project used 1300 WORM resistance thermometers and 1300 TRX transmitters. The transmitter carries a full set of hazardous area approvals and suits installation at the wellhead and on process sites. Outside oil and gas, it serves solar- or battery-powered measurement systems where voltage headroom in the loop is needed.

Technical specifications

Inputany thermocouple (TC) or RTD
Output signal4-20 mA
Lift-off voltage8 V
Load capability20 mA into 100 ohm at 10 V
Voltage signal0-1 V across a 50 ohm resistor
Supply in typical circuitsolar installation, 10-24 V
Sensor in typical circuitWORM, 4-wire Pt RTD
Hazardous areaapprovals for hazardous areas

Part numbers

Show all part numbers (1)

TRX

Request a price and lead time

TRX Low Power Temperature Transmitter with 8 V Lift-off Voltage for Remote Oil and Gas Sites. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What is the minimum supply voltage of the loop?

The lift-off voltage is 8 V. At 10 V the transmitter passes 20 mA through a 100 ohm load.

How do I feed a 0-1 V input of a flow computer?

Fit a 50 ohm resistor into the 4-20 mA loop. The voltage across it, 0-1 V, corresponds to the temperature range.

Which sensors can be connected?

The universal input accepts any thermocouple or resistance thermometer. At oil and gas sites it is used with a four-wire platinum WORM RTD.