A kit that records the temperature profile of parts inside vacuum physical vapour deposition furnaces. It comprises a 10-channel TP6 logger housed in a TB5014 thermal barrier, and comes with analysis software. The logger goes through the cycle alongside the parts and records surface temperatures from its thermocouples.

Logger
TP6
Channels
10
Measuring range
-100 to 1370 °C
Accuracy
±0.3 °C

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The Oven Tracker range is used when new parts and coatings are introduced, when a coating curing profile needs confirming, and when a furnace fault has to be traced. The profile shows deviations at once, so corrective action can be taken. Typical applications are vacuum and PVD furnaces, coating curing, high-end consumer goods, jewellery and medical devices, where exact part temperatures through the cycle are needed to achieve a strong, smooth coating.

The TP6 logger sits directly in the furnace, with up to ten thermocouples attached to the part, and records the surface temperature. Its measuring range is -100 to 1370 °C, accuracy ±0.3 °C and resolution 0.1 °C, with 4 million points of memory. Logging intervals run from 0.05 seconds to 10 minutes, and the specification also gives 0.2 seconds to 50 minutes. The unit is rated IP67, communicates over USB or Bluetooth, and runs on alkaline, NiMH or lithium cells. The NiMH battery can be replaced by the user.

The TB5014 thermal barrier shields the logger inside the vacuum furnace and keeps the chamber clean. It has a stainless steel body with high thermal mass and a sealed front panel, plus a pair of TB1001 heat sinks. At 150 °C the barrier lasts 6 hours, and at 200 °C it lasts 4 hours; its maximum operating temperature is 300 °C. Its mass is 7.8 kg, and its overall size is 100 by 146 by 303 mm.

Insight analysis software overlays and compares profiles, plots reference and tolerance curves, runs statistical process control (SPC), raises analysis alarms and produces reports that can be emailed. An optimisation tool estimates how a change in furnace settings will alter the profile, which cuts down on trial runs when setting a recipe. A mobile app allows data to be viewed on the move.

Technical specifications

LoggerTP6
Channels10
Measuring range-100 to 1370 °C
Accuracy±0.3 °C
Resolution0.1 °C
Logging interval0.05 s to 10 min
Memory4 million points
Powerreplaceable NiMH battery; alkaline or lithium cells also
Logger protectionIP67
CommunicationUSB, Bluetooth
Thermal barrierTB5014, stainless steel
Barrier endurance6 h at 150 °C; 4 h at 200 °C
Maximum barrier temperature300 °C
Heat sinksTB1001 x 2
Barrier weight7.8 kg
Barrier dimensions100 by 146 by 303 mm

Part numbers

Show all part numbers (3)

TP6, TB5014, TB1001

Request a price and lead time

TP6 and TB5014 Thermal Profiler for PVD Processes, 10 Channels, Up to 1370 °C. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many thermocouples can be connected to the logger?

Up to ten. They are attached to the part, and the logger records the surface temperature throughout the furnace cycle.

How long can the barrier stay in the furnace?

The barrier is rated for six hours at 150 °C and four hours at 200 °C, with a ceiling of 300 °C.

How is the data retrieved?

Over USB or Bluetooth into the Insight analysis software, which builds profiles, tolerance curves and reports. A mobile app is also available.