TM2000 Trace Oxygen Analyser with Zirconia Sensor, 0.1 ppm to 100% O2
The TM2000 is a zirconium oxide trace oxygen analyser for industrial gas processes. It covers 0.1 ppm to 100% O2 and responds to a change from atmospheric level down to low ppm within seconds.
- Measuring principle
- zirconium oxide (ZrO2)
- Range
- 0.1 ppm to 100% O2
- Accuracy (percent)
- ±1.0% of reading
- Accuracy (ppm)
- ±2% of reading or 0.5 ppm O2 absolute
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The TM2000 measures oxygen in process gases from atmospheric levels down to parts per million. Its main uses are checking the purity of inert gases, controlling furnace atmospheres, cryogenic gas production, specialist welding and air separation. The modular design makes upgrading and on-site servicing simpler.
The zirconia sensor does not fail to a zero oxygen reading, so the process stays protected even when a fault occurs. Calibration can be carried out with percentage gas mixtures, even for measurements in the ppm range.
Accuracy is ±1.0% of reading in the percent range and ±2% of reading or 0.5 ppm O2 absolute in the ppm range, whichever is greater. Repeatability is ±0.5% of reading or 0.1% O2 absolute, and the response time is under 5 seconds at 0.6 L/min (1.3 scfh) over one decade. Sample flow runs from 0.1 to 1.0 L/min, the inlet temperature can reach 71 °C (160 °F), and the inlet pressure is limited to 20 PSIG.
The sensor sits in a NEMA 3R enclosure of polyurethane-coated carbon steel and works indoors or outdoors at temperatures from -18 to 50 °C. Power is 115 V AC ±10%, 50/60 Hz, up to 288 VA, with 230 V optional. The control unit has a four-line, 20-character vacuum fluorescent display, two isolated current outputs (4-20, 0-20, 20-4 or 20-0 mA), two independent O2 alarms and an RS-485 port. Its NEMA 4 (IP 56) housing is for wall or panel mounting, with NEMA 4X stainless steel as an option, and it runs on 115 to 230 V AC ±10%, 47 to 63 Hz, drawing up to 75 VA.
A sample bypass of 25 or 50 L/min is optional and needs at least 6 PSIG, while the standard sensor without bypass runs from 1.5 PSIG. For automatic calibration with clean gas, a remote calibration unit in a UL Type 4X enclosure can sit up to 15 feet from the sensor.
Technical specifications
| Measuring principle | zirconium oxide (ZrO2) |
|---|---|
| Range | 0.1 ppm to 100% O2 |
| Accuracy (percent) | ±1.0% of reading |
| Accuracy (ppm) | ±2% of reading or 0.5 ppm O2 absolute |
| Repeatability | ±0.5% of reading or 0.1% O2 absolute (0.1 ppm) |
| Response time | under 5 s at 0.6 L/min per decade |
| Sample flow | 0.1 to 1.0 L/min (0.2 to 2.1 scfh) |
| Sample inlet temperature | up to 71 °C (160 °F) |
| Maximum inlet pressure | 20 PSIG |
| Ambient temperature, sensor | -18 to 50 °C |
| Ambient temperature, control unit | -10 to 50 °C |
| Sensor power | 115 V AC ±10%, 50/60 Hz, 288 VA (230 V optional) |
| Control unit power | 115–230 V AC ±10%, 47–63 Hz, 75 VA |
| Analogue outputs | 2 isolated, 4–20 / 0–20 / 20–4 / 20–0 mA |
| Alarms | 2 independent O2 alarms, contacts 0.5 A, 30 V |
| Interface | RS-485, two-way addressable |
| Sensor housing | NEMA 3R |
| Control unit housing | NEMA 4 (IP 56); optional NEMA 4X |
| Maximum altitude | 2000 m |
Request a price and lead time
TM2000 Trace Oxygen Analyser with Zirconia Sensor, 0.1 ppm to 100% O2. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What does the analyser show if the sensor fails?
The zirconia sensor does not fail to a zero oxygen reading, so the process remains protected.
Can the TM2000 be calibrated for ppm readings with percentage gas?
Yes, percentage calibration mixtures are sufficient even for the ppm range. A remote calibration unit can perform automatic calibration.
What sample pressure is needed?
The standard sensor runs from 1.5 PSIG, while a sample bypass requires at least 6 PSIG. The maximum inlet pressure is 20 PSIG.